Imaging Scanning Monochromator H1034
Imaging Scanning Monochromator H1034
Imaging Scanning Monochromator H1034
Imaging Scanning Monochromator H1034
Imaging Scanning Monochromator H1034
Imaging Scanning Monochromator H1034
Imaging Scanning Monochromator H1034
Imaging Scanning Monochromator H1034
Imaging Scanning Monochromator H1034
Imaging Scanning Monochromator H1034
Imaging Scanning Monochromator H1034
Imaging Scanning Monochromator H1034
New
Imaging Scanning Monochromator H1034
Imaging Scanning Monochromator H1034
Imaging Scanning Monochromator H1034
Imaging Scanning Monochromator H1034
Imaging Scanning Monochromator H1034
Imaging Scanning Monochromator H1034
Imaging Scanning Monochromator H1034
Imaging Scanning Monochromator H1034
Imaging Scanning Monochromator H1034
Imaging Scanning Monochromator H1034
Imaging Scanning Monochromator H1034
Imaging Scanning Monochromator H1034

Imaging Scanning Monochromator H1034

Overview


Imaging Scanning Monochromator

HORIBA Scientific OEM has developed a high-throughput imaging scanning monochromator based on an aberration-corrected concave holographic grating with low stray light and high efficiency. This proprietary layout with single optics design is ideal for imaging for low-light applications. It features a 3-position external filter wheel, TTL drive electronics, 4-phase stepper motor and associated worm/gear 90:1 ratio mechanism, encoded, aligned and focused at factory.

This instrument can be used as both a tunable excitation light source and a fluorescence emission scanning monochromator, thanks to high grating efficiency in both first and second orders of diffraction. It is also equipped with two opto-sensors and associated hardware for home calibration.

For OEM Industrial Applications

Absorbance, Fluorescence and Emission such as :
ㆍ Life Sciences (Plate Readers)
ㆍ Chemical Analysis
ㆍ High-performance Liquid Chromatography (HPLC)
ㆍ End-point Determination
ㆍ Color Measurement
ㆍ Environmental, Agricultural and Food

Features

ㆍ Scanning monochromator with superb imaging
ㆍ Covering UV to NIR range
ㆍ High throughput and low stray light
ㆍ Fast, reliable and reproducible
ㆍ 4-phase stepper motor and associated worm/gear 90:1 ratio mechanism
ㆍ 3-position external filter wheel and TTL drive electronics
ㆍ Many grating choices

OEM Spectrometer Selection Guide

Specifications

General Monochromator Specifications*
Spectral Coverage 185 – 1,100 nm (Effective coverage depending on grating blaze selection)
Spectrometer Input Free space; SMA; Customization on request
Spectral Resolution <1 nm with 100 μm x 8 mm slit
Focal Length 100 mm
Optical Dispersion 7.8 nm/mm
Stray Light < 0.1% (typical)
Wavelength Accuracy ± 1 nm with linear fitting
Step Repeatability ± 0.1 nm (with 1,200 g/mm grating)
F/# F/2.8
Option: OEM drive electronics with custom console app

Grating Selection

H1034 monochromator can be built with several grating choices that all have the same parameters such as curvature, groove density, correction of the aberrations, angle of deviation, and more.

What differs among them is the blazed wavelength.

Grating Type Blaze Wavelength
Aberration-corrected
Concave Holographic
Grating
250 nm
(covering 185-1,000 nm)
350 nm
(covering 185-1,000 nm)
500 nm
(covering 300-1,000 nm)
570 nm
(covering 350-1,000 nm)
Groove Density 1,200 (gr/mm)
F/# F/2.8
Dimension 38 mm x 38 mm and 42.4 x 42.4 (± 0.1) mm
Input/output angle of deviation 34.7°
Input arm length 105.19 mm
Exit arm length 100.46 mm
Coating Aluminum
Grating efficiency See the plots below

Grating Efficiency Curves

H1034 gratings can be used in first order for emission scanning and in second and first orders for excitation scanning.

Additional H1034 Monochromator Specifications

1-Motor Drive

H1034 monochromator features a 4-phase stepper motor and associated worm/gear 90:1 ratio mechanism, encoded, aligned and focused. Two opto-sensors and associated hardware for home calibration are included in this OEM configuration.

Monochromator stepper motor scanning configuration
Microstepping 8 μ steps per step
Initial velocity or Minimum speed 300 steps / sec
Maximum speed 800 steps / sec
Ramp-up acceleration 8,000 steps / sec2
Ramp-down acceleration 8,000 steps / sec2
Threshold speed 1,400 steps/sec

2- Filter Wheel (Optional)

Three-position compact filter wheel with NEMA 8 stepper motor and opto-sensor for homing that can be completely customized to customer’s requirements (number of filters, filter sizes, positions, etc).

Filter wheel stepper motor scanning configuration
Microstepping 8 μ steps per step
Initial velocity or Minimum speed 0 steps / sec
Maximum speed 500 steps / sec
Ramp-up acceleration 20,008 steps / sec2
Ramp-down acceleration 2,008 steps / sec2
Threshold speed 595 steps / sec

3- Interchangeable Input and Output Slits (Optional)

H1034 monochromator is upgradable to have interchangeable input and output slits with various selections of slit width from 0.012 mm to 4.25 mm and 8 mm height.

4- Drive Electronics for Monochromator and Filter Wheel

H1034 drive electronics with custom software is designed to control the monochromator components and its accessories.

Drive Electronics for H1034 monochromator system.
OEM Industrial grade.

5- Console Application Software & DLL Features

OEM drive electronics has custom software for the H1034 monochromator and the optional shutter/order-sorting mechanism. It is delivered with a console app demo software for fast prototyping, debugging and testing with a super-user configuration tool for customization of the operating parameters, a DLL driver and associated documentation for custom programming (e.g., C#) and integration within the customer’s top-level software.

Mechanical Drawings

Detailed specification sheets are shown in the product images.

Catalogues

Error product group when enable variant picker

Imaging Scanning Monochromator H1034

Imaging Scanning Monochromator H1034

$0.00

Imaging Scanning Monochromator H1034: overview and buying guide

The Imaging Scanning Monochromator H1034 (model H1034) is made by HORIBA and listed in our test · measurement range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.

Frequently asked questions

How much does the Imaging Scanning Monochromator H1034 cost?

Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.

Can you ship the Imaging Scanning Monochromator H1034 to my country?

Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.

Is this a genuine HORIBA product?

We purchase directly from HORIBA or its authorised channels and confirm the model and specifications with the manufacturer before ordering.

What is the minimum order quantity?

For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.

Overview


Imaging Scanning Monochromator

HORIBA Scientific OEM has developed a high-throughput imaging scanning monochromator based on an aberration-corrected concave holographic grating with low stray light and high efficiency. This proprietary layout with single optics design is ideal for imaging for low-light applications. It features a 3-position external filter wheel, TTL drive electronics, 4-phase stepper motor and associated worm/gear 90:1 ratio mechanism, encoded, aligned and focused at factory.

This instrument can be used as both a tunable excitation light source and a fluorescence emission scanning monochromator, thanks to high grating efficiency in both first and second orders of diffraction. It is also equipped with two opto-sensors and associated hardware for home calibration.

For OEM Industrial Applications

Absorbance, Fluorescence and Emission such as :
ㆍ Life Sciences (Plate Readers)
ㆍ Chemical Analysis
ㆍ High-performance Liquid Chromatography (HPLC)
ㆍ End-point Determination
ㆍ Color Measurement
ㆍ Environmental, Agricultural and Food

Features

ㆍ Scanning monochromator with superb imaging
ㆍ Covering UV to NIR range
ㆍ High throughput and low stray light
ㆍ Fast, reliable and reproducible
ㆍ 4-phase stepper motor and associated worm/gear 90:1 ratio mechanism
ㆍ 3-position external filter wheel and TTL drive electronics
ㆍ Many grating choices

OEM Spectrometer Selection Guide

Specifications

General Monochromator Specifications*
Spectral Coverage 185 – 1,100 nm (Effective coverage depending on grating blaze selection)
Spectrometer Input Free space; SMA; Customization on request
Spectral Resolution <1 nm with 100 μm x 8 mm slit
Focal Length 100 mm
Optical Dispersion 7.8 nm/mm
Stray Light < 0.1% (typical)
Wavelength Accuracy ± 1 nm with linear fitting
Step Repeatability ± 0.1 nm (with 1,200 g/mm grating)
F/# F/2.8
Option: OEM drive electronics with custom console app

Grating Selection

H1034 monochromator can be built with several grating choices that all have the same parameters such as curvature, groove density, correction of the aberrations, angle of deviation, and more.

What differs among them is the blazed wavelength.

Grating Type Blaze Wavelength
Aberration-corrected
Concave Holographic
Grating
250 nm
(covering 185-1,000 nm)
350 nm
(covering 185-1,000 nm)
500 nm
(covering 300-1,000 nm)
570 nm
(covering 350-1,000 nm)
Groove Density 1,200 (gr/mm)
F/# F/2.8
Dimension 38 mm x 38 mm and 42.4 x 42.4 (± 0.1) mm
Input/output angle of deviation 34.7°
Input arm length 105.19 mm
Exit arm length 100.46 mm
Coating Aluminum
Grating efficiency See the plots below

Grating Efficiency Curves

H1034 gratings can be used in first order for emission scanning and in second and first orders for excitation scanning.

Additional H1034 Monochromator Specifications

1-Motor Drive

H1034 monochromator features a 4-phase stepper motor and associated worm/gear 90:1 ratio mechanism, encoded, aligned and focused. Two opto-sensors and associated hardware for home calibration are included in this OEM configuration.

Monochromator stepper motor scanning configuration
Microstepping 8 μ steps per step
Initial velocity or Minimum speed 300 steps / sec
Maximum speed 800 steps / sec
Ramp-up acceleration 8,000 steps / sec2
Ramp-down acceleration 8,000 steps / sec2
Threshold speed 1,400 steps/sec

2- Filter Wheel (Optional)

Three-position compact filter wheel with NEMA 8 stepper motor and opto-sensor for homing that can be completely customized to customer’s requirements (number of filters, filter sizes, positions, etc).

Filter wheel stepper motor scanning configuration
Microstepping 8 μ steps per step
Initial velocity or Minimum speed 0 steps / sec
Maximum speed 500 steps / sec
Ramp-up acceleration 20,008 steps / sec2
Ramp-down acceleration 2,008 steps / sec2
Threshold speed 595 steps / sec

3- Interchangeable Input and Output Slits (Optional)

H1034 monochromator is upgradable to have interchangeable input and output slits with various selections of slit width from 0.012 mm to 4.25 mm and 8 mm height.

4- Drive Electronics for Monochromator and Filter Wheel

H1034 drive electronics with custom software is designed to control the monochromator components and its accessories.

Drive Electronics for H1034 monochromator system.
OEM Industrial grade.

5- Console Application Software & DLL Features

OEM drive electronics has custom software for the H1034 monochromator and the optional shutter/order-sorting mechanism. It is delivered with a console app demo software for fast prototyping, debugging and testing with a super-user configuration tool for customization of the operating parameters, a DLL driver and associated documentation for custom programming (e.g., C#) and integration within the customer’s top-level software.

Mechanical Drawings

Detailed specification sheets are shown in the product images.