Hyperspectral Imaging Systems PoliSpectra® H116
Hyperspectral Imaging Systems PoliSpectra® H116
Hyperspectral Imaging Systems PoliSpectra® H116
Hyperspectral Imaging Systems PoliSpectra® H116
Hyperspectral Imaging Systems PoliSpectra® H116
Hyperspectral Imaging Systems PoliSpectra® H116
Hyperspectral Imaging Systems PoliSpectra® H116
Hyperspectral Imaging Systems PoliSpectra® H116
Hyperspectral Imaging Systems PoliSpectra® H116
Hyperspectral Imaging Systems PoliSpectra® H116
New
Hyperspectral Imaging Systems PoliSpectra® H116
Hyperspectral Imaging Systems PoliSpectra® H116
Hyperspectral Imaging Systems PoliSpectra® H116
Hyperspectral Imaging Systems PoliSpectra® H116
Hyperspectral Imaging Systems PoliSpectra® H116
Hyperspectral Imaging Systems PoliSpectra® H116
Hyperspectral Imaging Systems PoliSpectra® H116
Hyperspectral Imaging Systems PoliSpectra® H116
Hyperspectral Imaging Systems PoliSpectra® H116
Hyperspectral Imaging Systems PoliSpectra® H116

Hyperspectral Imaging Systems PoliSpectra® H116

Overview


Hyperspectral Imaging Spectrometer Applications

HORIBA has developed a unique hyperspectral imaging spectrometer with an integrated scientific CMOS camera (12-16 bit) featuring HDR (95dB Dynamic Range and 1.7e- noise) and 95% Q.E peak efficiency:

PoliSpectra® H116 features broad UV-NIR coverage in one acquisition (185-1050 nm) combined with the highest spectral resolution (<1 nm).

The elegant all-concentric design combines high spatial and spectral resolution using a type-I holographic diffraction grating. This system is used as a line-scanning instrument (push-broom) that collects full spectral data simultaneously, across the input slit height at 188 frames per second (or higher with AOI/binning).

For OEM hyperspectral and multispectral applications

ㆍ Remote Sensing (Aerial - drone/uas/uav or aircraft…)
ㆍ Quality Control Inspection / Optical metrology in Semiconductors
ㆍ DNA sequencing / Capillary Electrophoresis / PCR
ㆍ Process Monitoring by Reflectometry, Emission, Raman, Fluorescence…
ㆍ Microscopy (Mapping, Complete custom solutions)
ㆍ Advanced Machine Vision / Industrial camera
ㆍ Recycling (Sorting and quality control in recycling plants)
ㆍ Food & Beverage Inspection

Features

ㆍ Superb imaging quality
ㆍ Frame rates as fast as 188 fr/s
ㆍ High spectral and spatial resolution at F/2.3
ㆍ High throughput combined with low stray light performance
ㆍ 2D Scientific CMOS with high quantum efficiency and low noise
ㆍ Broad wavelength coverage from 185 nm to 1050 nm
ㆍ Stable and robust

Thermal stability study cycling from -20ºC to 50ºC

Scientific CMOS Back-Illuminated Sensor Quantum Efficiency

Hyperspectral Imaging Distortions: Keystone and Smile

OEM Spectrometer Selection Guide

Specifications

General Spectrometer Specifications*

Spectral Coverage 185–1050 nm
Tunable at factory between these ranges: 185-920 nm and 280-1050 nm
Spectral Resolution 1.25 nm typical (22 μm slit width) and up, depending on the slit size
Spatial Resolution 50 µm typical
Spectral Dispersion 34.6 nm/mm; 0.38 nm/pixel
Focal Length 116 mm
F/# F/2.3
Smile and Keystone 1.5 pixel (typical)
Stray Light** < 0.1% (typical)
Wavelength Accuracy 0.1 nm (using multi-area wavelength calibration)
Software LabVIEW™ acquisition software for initial evaluation (DLLs provided for software integration)

Specifications for Scientific Back-Illuminated CMOS Image Sensor with High Speed Electronics

Detector Model sCMOS BI sensor with electronic rolling shutter (All the parameters are specified at normal room temperature of 25º C unless otherwise noted)
Sensor Format*** 2048 x 512
CMOS Pixel Size 11 µm x 11 µm
CMOS Height 5.6 mm
CMOS QE The peak QE is 77% at 250 nm and 95% at 560 nm (refer to graphs below)
Thermoelectric Cooling Uncooled
Frame Rate 94 fps (HDR mode), 188 fps (STD mode) on 2D sCMOS sensor
Full Well 80 ke¯ typical (HDR mode)
Readout Noise 1.6 e¯ typical, 2.0 e¯ maximum
Digitization 16-bit (HDR mode), 12-bit (High Sensitivity mode
Dynamic Range (HDR mode) 93.9 dB typical in HDR mode
Non-linearity
(measured on each system)
< 1.8% (maximum) in HDR mode <0.9% (maximum) at high gain
Communication USB 3
Environmental Conditions Operating temperature 15° C to 40°C ambient;
Relative humidity <70% (non-condensing); Storage temperature -25° C to 45° C
Power requirements
AC/DC Power Supply (provided)
90-264 VAC, 47–63 Hz

* Specifications, form factor, and spectrometer cover subject to change without notice. No LabVIEW license is needed to run our acquisition software.

** Stray light using BP Filter: Baseline light level, outside the band, divided by BP peak (unsaturated) value.

Scientific CMOS Back-Illuminated Sensor Quantum Efficiency

Mechanical Drawings

Detailed specification sheets are shown in the product images.

Catalogues

Error product group when enable variant picker

Hyperspectral Imaging Systems PoliSpectra® H116

Hyperspectral Imaging Systems PoliSpectra® H116

$0.00

Hyperspectral Imaging Systems PoliSpectra® H116: overview and buying guide

The Hyperspectral Imaging Systems PoliSpectra® H116 (model PoliSpectra® H116) is made by HORIBA and listed in our test · measurement range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.

Frequently asked questions

How much does the Hyperspectral Imaging Systems PoliSpectra® H116 cost?

Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.

Can you ship the Hyperspectral Imaging Systems PoliSpectra® H116 to my country?

Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.

Is this a genuine HORIBA product?

We purchase directly from HORIBA or its authorised channels and confirm the model and specifications with the manufacturer before ordering.

What is the minimum order quantity?

For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.

Overview


Hyperspectral Imaging Spectrometer Applications

HORIBA has developed a unique hyperspectral imaging spectrometer with an integrated scientific CMOS camera (12-16 bit) featuring HDR (95dB Dynamic Range and 1.7e- noise) and 95% Q.E peak efficiency:

PoliSpectra® H116 features broad UV-NIR coverage in one acquisition (185-1050 nm) combined with the highest spectral resolution (<1 nm).

The elegant all-concentric design combines high spatial and spectral resolution using a type-I holographic diffraction grating. This system is used as a line-scanning instrument (push-broom) that collects full spectral data simultaneously, across the input slit height at 188 frames per second (or higher with AOI/binning).

For OEM hyperspectral and multispectral applications

ㆍ Remote Sensing (Aerial - drone/uas/uav or aircraft…)
ㆍ Quality Control Inspection / Optical metrology in Semiconductors
ㆍ DNA sequencing / Capillary Electrophoresis / PCR
ㆍ Process Monitoring by Reflectometry, Emission, Raman, Fluorescence…
ㆍ Microscopy (Mapping, Complete custom solutions)
ㆍ Advanced Machine Vision / Industrial camera
ㆍ Recycling (Sorting and quality control in recycling plants)
ㆍ Food & Beverage Inspection

Features

ㆍ Superb imaging quality
ㆍ Frame rates as fast as 188 fr/s
ㆍ High spectral and spatial resolution at F/2.3
ㆍ High throughput combined with low stray light performance
ㆍ 2D Scientific CMOS with high quantum efficiency and low noise
ㆍ Broad wavelength coverage from 185 nm to 1050 nm
ㆍ Stable and robust

Thermal stability study cycling from -20ºC to 50ºC

Scientific CMOS Back-Illuminated Sensor Quantum Efficiency

Hyperspectral Imaging Distortions: Keystone and Smile

OEM Spectrometer Selection Guide

Specifications

General Spectrometer Specifications*

Spectral Coverage 185–1050 nm
Tunable at factory between these ranges: 185-920 nm and 280-1050 nm
Spectral Resolution 1.25 nm typical (22 μm slit width) and up, depending on the slit size
Spatial Resolution 50 µm typical
Spectral Dispersion 34.6 nm/mm; 0.38 nm/pixel
Focal Length 116 mm
F/# F/2.3
Smile and Keystone 1.5 pixel (typical)
Stray Light** < 0.1% (typical)
Wavelength Accuracy 0.1 nm (using multi-area wavelength calibration)
Software LabVIEW™ acquisition software for initial evaluation (DLLs provided for software integration)

Specifications for Scientific Back-Illuminated CMOS Image Sensor with High Speed Electronics

Detector Model sCMOS BI sensor with electronic rolling shutter (All the parameters are specified at normal room temperature of 25º C unless otherwise noted)
Sensor Format*** 2048 x 512
CMOS Pixel Size 11 µm x 11 µm
CMOS Height 5.6 mm
CMOS QE The peak QE is 77% at 250 nm and 95% at 560 nm (refer to graphs below)
Thermoelectric Cooling Uncooled
Frame Rate 94 fps (HDR mode), 188 fps (STD mode) on 2D sCMOS sensor
Full Well 80 ke¯ typical (HDR mode)
Readout Noise 1.6 e¯ typical, 2.0 e¯ maximum
Digitization 16-bit (HDR mode), 12-bit (High Sensitivity mode
Dynamic Range (HDR mode) 93.9 dB typical in HDR mode
Non-linearity
(measured on each system)
< 1.8% (maximum) in HDR mode <0.9% (maximum) at high gain
Communication USB 3
Environmental Conditions Operating temperature 15° C to 40°C ambient;
Relative humidity <70% (non-condensing); Storage temperature -25° C to 45° C
Power requirements
AC/DC Power Supply (provided)
90-264 VAC, 47–63 Hz

* Specifications, form factor, and spectrometer cover subject to change without notice. No LabVIEW license is needed to run our acquisition software.

** Stray light using BP Filter: Baseline light level, outside the band, divided by BP peak (unsaturated) value.

Scientific CMOS Back-Illuminated Sensor Quantum Efficiency

Mechanical Drawings

Detailed specification sheets are shown in the product images.

Catalogues