Hydro Block
General Description
Just one component combines all the functions necessary to a water unit block of a wall mounted boiler, allowing a reduction of assembling workmanship costs. Compared to a traditional system we hav a performances improving, a low pressure drop on the heating circuit, a santiary hot water fast output and a dimensional compactness easy to obtain using a standard circulator
OPERATION FEATURES
TECHNICAL DATA
- Max. sanitary working pressure 10 bar
- Max. sanitary test pressure 15 bar
- Max. heating circuit working pressure 3 bar
- Max. heating circuit test pressure 4,5 bar
- Max. water working temperature 90℃
- Max. ambient emperature 60℃
- Diverter valve power supply
240 VAC/50Hz or 24 VAC/50Hz
- Diverter valve working time
3 or 1,5 secondi(*)
- Diverter valve switching time to heating circuit
9 or 4,5 secondi(*)
- Diverter valve power consumption 3W
- Switching flow rate for sanitary water
ON-2,7/OFF=1,9(0,3)l/min(*)
- Flowswitch electric contact(reed) 50 VA
- Pipe connections according to DIN 3368 STD
Detailed specification sheets are shown in the product images.
Hydro Block
Hydro Block: overview and buying guide
The Hydro Block is made by ALCO and listed in our hvac range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.
Frequently asked questions
How much does the Hydro Block cost?
Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.
Can you ship the Hydro Block to my country?
Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.
Is this a genuine ALCO product?
We purchase directly from ALCO or its authorised channels and confirm the model and specifications with the manufacturer before ordering.
What is the minimum order quantity?
For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.
General Description
Just one component combines all the functions necessary to a water unit block of a wall mounted boiler, allowing a reduction of assembling workmanship costs. Compared to a traditional system we hav a performances improving, a low pressure drop on the heating circuit, a santiary hot water fast output and a dimensional compactness easy to obtain using a standard circulator
OPERATION FEATURES
TECHNICAL DATA
- Max. sanitary working pressure 10 bar
- Max. sanitary test pressure 15 bar
- Max. heating circuit working pressure 3 bar
- Max. heating circuit test pressure 4,5 bar
- Max. water working temperature 90℃
- Max. ambient emperature 60℃
- Diverter valve power supply
240 VAC/50Hz or 24 VAC/50Hz
- Diverter valve working time
3 or 1,5 secondi(*)
- Diverter valve switching time to heating circuit
9 or 4,5 secondi(*)
- Diverter valve power consumption 3W
- Switching flow rate for sanitary water
ON-2,7/OFF=1,9(0,3)l/min(*)
- Flowswitch electric contact(reed) 50 VA
- Pipe connections according to DIN 3368 STD
Detailed specification sheets are shown in the product images.