High Voltage Substation Facility
High Voltage Substation Facility
High Voltage Substation Facility
High Voltage Substation Facility
High Voltage Substation Facility
High Voltage Substation Facility
High Voltage Substation Facility
High Voltage Substation Facility
New
High Voltage Substation Facility
High Voltage Substation Facility
High Voltage Substation Facility
High Voltage Substation Facility
High Voltage Substation Facility
High Voltage Substation Facility
High Voltage Substation Facility
High Voltage Substation Facility

High Voltage Substation Facility

Transformer

With our high voltage transformers(66kV~765kV) as our main product, we also produce transformers for transmission, reception & distribution of power within factory as well as furnace transformers. Also, we provide flawless services from installation to operation.


[Production Range]

ILJIN’s transformers are in service around the world and meet international standards such as IEC,ANSI

High Voltage GIS

The SF6 Gas Insulated Switchgear (GIS) contains major substation equipment, such as the gas circuit breaker, disconnecting switch, earthing switch, voltage transformer, current transformer, and lightning arrester, within a grounded metallic enclosure filled with SF6 gas to provide the best possible insulation and arc-quenching capabilities.
ILJIN’s GIS is the most highly-developed switchgear on the market today. Our products provide features such as compact designs, safety, reliability, simplified operation, long maintenance intervals and compatibility with surrounding systems. Our recently developed 3-phase encapsulated GIS is an example of the economical and compact substation design our customers have come to know and expect from ILJIN.


[Feature & Advantage]

1) Reliability
·A circuit breaker which surpasses the KERI and KEMA standards outlined in the latest IEC standards (IEC 62271-203 & IEC 62271-100).
·A phase common enclosure for fewer components and no errors.
·A high-quality circuit breaker featuring a hydraulic operating mechanism (170kV GIS) or a motor operated spring mechanism (25.8kV, 36kV, 72.5kV GIS, 145kV GIS, 245kV GIS).


2) Compact Design
·A small and lightweight phase common enclosure design (72.5kV GIS, 145kV GIS, 170kV GIS).
·A CT housed in the CB and a line disconnecting switch, line earthing switch, and work earthing switch contained in a single enclosure to reduce size and weight.
·A CB motor operated spring mechanism adopted to make our GIS lighter and more compact than comparable models (25.8kV, 36kV, 72.5kV GIS, 145kV GIS, 245kV GIS).


3) Safety
·Earthed enclosure to provide improved protection against current leakage.
·Interlocking system to optimize system operation.


4) Modular Design
·Standardized modules to improve production quality and allow for easy assembly.


5) Gas Tightness
·Standardized sealing ring (O-ring) system to reduce the number of pipes and valves in each system and improve gas tightness.


6) Adoption of the Puffer & Hybrid Type Gas Circuit Breaker
·Puffer & hybrid type gas circuit breaker for simplified construction, fewer components, no gas heating of components, and enhanced reliability.

Medium Voltage GIS

The encapsulated type MV GIS(25.8/36kV) is installed at a substation to safely and promptly break fault current as well as load current. This product is intended to improve the supply reliability by isolating defective sections and restricting propagation of accidents. It is also designed to enhance stability with high-speed reclosing.
The SF6 Gas Insulated Switchgear (GIS) contains major substation equipment, such as the gas circuit breaker, disconnecting switch, earthing switch, voltage transformer, current transformer, and lightning arrester, within a grounded metallic enclosure filled with SF6 gas to provide the best possible insulation and arc-quenching capabilities.
ILJIN’s GIS is the most highly-developed switchgear on the market today. Our products provide features such as compact designs, safety, reliability, simplified operation, long maintenance intervals and compatibility with surrounding systems. Our recently developed 3-phase encapsulated GIS is an example of the economical and compact substation design our customers have come to know and expect from ILJIN.


[Feature & Advantage]

1) Reliability
· A circuit breaker which surpasses the KERI and KEMA standards outlined in the latest IEC standards (IEC 62271-203 & IEC 62271-100).
· A phase common enclosure for fewer components and no errors.
· A high-quality circuit breaker featuring a hydraulic operating mechanism (170kV GIS) or a motor operated spring mechanism (25.8kV, 36kV, 72.5kV GIS, 145kV GIS, 245kV GIS).

2) Compact Design
· A small and lightweight phase common enclosure design (72.5kV GIS, 145kV GIS, 170kV GIS).
· A CT housed in the CB and a line disconnecting switch, line earthing switch, and work earthing switch contained in a single enclosure to reduce size and weight.
· A CB motor operated spring mechanism adopted to make our GIS lighter and more compact than comparable models (25.8kV, 36kV, 72.5kV GIS, 145kV GIS, 245kV GIS).

3) Safety
· Earthed enclosure to provide improved protection against current leakage.
· Interlocking system to optimize system operation.


4) Modular Design
· Standardized modules to improve production quality and allow for easy assembly.


5) Gas Tightness
· Standardized sealing ring (O-ring) system to reduce the number of pipes and valves in each system and improve gas tightness.


6) Adoption of the Puffer & Hybrid Type Gas Circuit Breaker
· Puffer & hybrid type gas circuit breaker for simplified construction, fewer components, no gas heating of components, and enhanced reliability.

Isolated Pulse Busduct

The IPB is suitable for large currents or important facilities and large scale power plants.

1) Rated Voltage: 12kV ~ 36kV

2) Rated Current: 1,000A ~ 5,000A

3) Designed for cooling system with Air Pressuring System

[Feature & Advantage]

1. Conductor : The octagonal or circular main conductor is made with 99.5% pure aluminum with excellent conductivity.

2. Enclosure: The circular enclosure is manufactured by welding aluminum plates of 99.5% purity with excellent conductivity.

3. Painting: The conductor and enclosure are painted in black to enhance heat radiation.

Detailed specification sheets are shown in the product images.

Catalogues

Error product group when enable variant picker

Availability: In stock
Categories: Electronic
High Voltage Substation Facility

High Voltage Substation Facility

$0.00

High Voltage Substation Facility: overview and buying guide

The High Voltage Substation Facility is made by ILJIN Electric and listed in our electronic range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.

Frequently asked questions

How much does the High Voltage Substation Facility cost?

Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.

Can you ship the High Voltage Substation Facility to my country?

Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.

Is this a genuine ILJIN Electric product?

We purchase directly from ILJIN Electric or its authorised channels and confirm the model and specifications with the manufacturer before ordering.

What is the minimum order quantity?

For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.

Transformer

With our high voltage transformers(66kV~765kV) as our main product, we also produce transformers for transmission, reception & distribution of power within factory as well as furnace transformers. Also, we provide flawless services from installation to operation.


[Production Range]

ILJIN’s transformers are in service around the world and meet international standards such as IEC,ANSI

High Voltage GIS

The SF6 Gas Insulated Switchgear (GIS) contains major substation equipment, such as the gas circuit breaker, disconnecting switch, earthing switch, voltage transformer, current transformer, and lightning arrester, within a grounded metallic enclosure filled with SF6 gas to provide the best possible insulation and arc-quenching capabilities.
ILJIN’s GIS is the most highly-developed switchgear on the market today. Our products provide features such as compact designs, safety, reliability, simplified operation, long maintenance intervals and compatibility with surrounding systems. Our recently developed 3-phase encapsulated GIS is an example of the economical and compact substation design our customers have come to know and expect from ILJIN.


[Feature & Advantage]

1) Reliability
·A circuit breaker which surpasses the KERI and KEMA standards outlined in the latest IEC standards (IEC 62271-203 & IEC 62271-100).
·A phase common enclosure for fewer components and no errors.
·A high-quality circuit breaker featuring a hydraulic operating mechanism (170kV GIS) or a motor operated spring mechanism (25.8kV, 36kV, 72.5kV GIS, 145kV GIS, 245kV GIS).


2) Compact Design
·A small and lightweight phase common enclosure design (72.5kV GIS, 145kV GIS, 170kV GIS).
·A CT housed in the CB and a line disconnecting switch, line earthing switch, and work earthing switch contained in a single enclosure to reduce size and weight.
·A CB motor operated spring mechanism adopted to make our GIS lighter and more compact than comparable models (25.8kV, 36kV, 72.5kV GIS, 145kV GIS, 245kV GIS).


3) Safety
·Earthed enclosure to provide improved protection against current leakage.
·Interlocking system to optimize system operation.


4) Modular Design
·Standardized modules to improve production quality and allow for easy assembly.


5) Gas Tightness
·Standardized sealing ring (O-ring) system to reduce the number of pipes and valves in each system and improve gas tightness.


6) Adoption of the Puffer & Hybrid Type Gas Circuit Breaker
·Puffer & hybrid type gas circuit breaker for simplified construction, fewer components, no gas heating of components, and enhanced reliability.

Medium Voltage GIS

The encapsulated type MV GIS(25.8/36kV) is installed at a substation to safely and promptly break fault current as well as load current. This product is intended to improve the supply reliability by isolating defective sections and restricting propagation of accidents. It is also designed to enhance stability with high-speed reclosing.
The SF6 Gas Insulated Switchgear (GIS) contains major substation equipment, such as the gas circuit breaker, disconnecting switch, earthing switch, voltage transformer, current transformer, and lightning arrester, within a grounded metallic enclosure filled with SF6 gas to provide the best possible insulation and arc-quenching capabilities.
ILJIN’s GIS is the most highly-developed switchgear on the market today. Our products provide features such as compact designs, safety, reliability, simplified operation, long maintenance intervals and compatibility with surrounding systems. Our recently developed 3-phase encapsulated GIS is an example of the economical and compact substation design our customers have come to know and expect from ILJIN.


[Feature & Advantage]

1) Reliability
· A circuit breaker which surpasses the KERI and KEMA standards outlined in the latest IEC standards (IEC 62271-203 & IEC 62271-100).
· A phase common enclosure for fewer components and no errors.
· A high-quality circuit breaker featuring a hydraulic operating mechanism (170kV GIS) or a motor operated spring mechanism (25.8kV, 36kV, 72.5kV GIS, 145kV GIS, 245kV GIS).

2) Compact Design
· A small and lightweight phase common enclosure design (72.5kV GIS, 145kV GIS, 170kV GIS).
· A CT housed in the CB and a line disconnecting switch, line earthing switch, and work earthing switch contained in a single enclosure to reduce size and weight.
· A CB motor operated spring mechanism adopted to make our GIS lighter and more compact than comparable models (25.8kV, 36kV, 72.5kV GIS, 145kV GIS, 245kV GIS).

3) Safety
· Earthed enclosure to provide improved protection against current leakage.
· Interlocking system to optimize system operation.


4) Modular Design
· Standardized modules to improve production quality and allow for easy assembly.


5) Gas Tightness
· Standardized sealing ring (O-ring) system to reduce the number of pipes and valves in each system and improve gas tightness.


6) Adoption of the Puffer & Hybrid Type Gas Circuit Breaker
· Puffer & hybrid type gas circuit breaker for simplified construction, fewer components, no gas heating of components, and enhanced reliability.

Isolated Pulse Busduct

The IPB is suitable for large currents or important facilities and large scale power plants.

1) Rated Voltage: 12kV ~ 36kV

2) Rated Current: 1,000A ~ 5,000A

3) Designed for cooling system with Air Pressuring System

[Feature & Advantage]

1. Conductor : The octagonal or circular main conductor is made with 99.5% pure aluminum with excellent conductivity.

2. Enclosure: The circular enclosure is manufactured by welding aluminum plates of 99.5% purity with excellent conductivity.

3. Painting: The conductor and enclosure are painted in black to enhance heat radiation.

Detailed specification sheets are shown in the product images.

Catalogues