High Efficient Boiler (Gas) BSS-EX Series
BSS Series EX Type [99% High Efficiency] Gas
Certified High-Efficiency Energy Equipment
Product Specifications
1. Traditional unit reference values are indicated in { } alongside.
2. The above specifications are based on the following criteria.
- Steam Pressure: 1MPa {10kgf/cm2}, Steam Enthalpy 2.78MJ/kg {663.7 kcal/kg}, Feed Water Temperature 293K{20℃} standard.
- Recommended supply pressure during GAS combustion is low pressure 1.96~2.45KPa (minimum 0.98KPa) {200~250mmH2O (minimum 100mmH2O)}.
- Recommended supply pressure during GAS combustion is medium pressure 34.32 9.81 KPa {3,500 1,000mmH2O}.
- The calorific values of each fuel are based on the following.
Natural Gas(13A) : High/Low Calorific Value 46.05/41.9 MJ/N㎥ {11,000/10,000 kcal/Nm3}
Propane : 101.9/93.8 MJ/Nm3 {24,350/22,400 kcal/Nm3} 50.1/46.4 MJ/N㎥ {11,969/11,089 kcal/kg}
Butane : 133.3/123.5 MJ/Nm3 {31,840/28,400 kcal/Nm3} 51.3/47.5 MJ/N㎥ {12,254/11,353 kcal/kg}
3. Boiler efficiency is based on the lower calorific value, at rated conditions.
4. It includes the following permissible values as unavoidable measurement errors.
- Boiler efficiency measurement error ±1%, Combustion amount (heat input) measurement error ±1.5%
5. If the water softener is to be controlled individually by the boiler control, 220V1¢ power is required.
6. Please understand that some changes may be made without prior notice for product performance improvement.
Product Features
1.Ultra High Efficiency(99%)
By adopting specially processed bulge water tubes and a reverse combustion method, and equipped with a high-performance feed water preheater (STS 304/316) to recover waste exhaust gas heat, 99% efficiency has been achieved.
(Investment cost recoverable within 3 years)
2.Multi-Unit Installation System
By installing multiple once-through scrum boilers to match the minimum load of the application, "supplying only the necessary amount of steam and maximizing the efficiency of each unit," fuel and maintenance costs can be significantly reduced.
3.Equipped with Air Preheater
By supplying combustion air heated to 50~60℃, combustion efficiency is maximized, increasing efficiency by 2~3%.
4.Equipped with Feed Water Preheater
Equipped with a specially processed high-performance feed water preheater (STS304/316), it maximizes the absorption of high-temperature exhaust gas heat generated after combustion, raising the feed water temperature and achieving maximum efficiency.
5.Steam Generation within 5 Minutes
Steam is generated within 5 minutes after boiler operation, reducing preheating loss, saving fuel costs, and allowing immediate operation.
(Approx. 10% fuel saving based on 8 hours/day)
6.Adoption of Distributed Combustion Method
The heat from reverse combustion is distributed through 40~70 passages, preventing local overheating inside the boiler and extending its lifespan.
7.Automatic Concentration Blowdown Device Standard Equipment
By automatically measuring the concentration of boiler water and always discharging only concentrated water above the standard value, the conductivity of the boiler water is maintained within the permissible range, preventing efficiency degradation and priming, and extending lifespan.
8.Perfect After-Sales Management System
Service personnel connected through 29 service networks nationwide are doing their best to ensure customers can use the product safely 24 hours a day.
9.Condensate Neutralization Treatment Device
Equipped with a storage tank containing magnesium rocks, it discharges water conforming to environmental water quality standards (pH 5.8 to 8.6), making it eco-friendly.
(96%~100% or more)
Detailed specification sheets are shown in the product images.
High Efficient Boiler (Gas) BSS-EX Series
High Efficient Boiler (Gas) BSS-EX Series: overview and buying guide
The High Efficient Boiler (Gas) BSS-EX Series (model BSS-EX Series) is made by BOOSTER and listed in our hvac range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.
Frequently asked questions
How much does the High Efficient Boiler (Gas) BSS-EX Series cost?
Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.
Can you ship the High Efficient Boiler (Gas) BSS-EX Series to my country?
Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.
Is this a genuine BOOSTER product?
We purchase directly from BOOSTER or its authorised channels and confirm the model and specifications with the manufacturer before ordering.
What is the minimum order quantity?
For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.
BSS Series EX Type [99% High Efficiency] Gas
Certified High-Efficiency Energy Equipment
Product Specifications
1. Traditional unit reference values are indicated in { } alongside.
2. The above specifications are based on the following criteria.
- Steam Pressure: 1MPa {10kgf/cm2}, Steam Enthalpy 2.78MJ/kg {663.7 kcal/kg}, Feed Water Temperature 293K{20℃} standard.
- Recommended supply pressure during GAS combustion is low pressure 1.96~2.45KPa (minimum 0.98KPa) {200~250mmH2O (minimum 100mmH2O)}.
- Recommended supply pressure during GAS combustion is medium pressure 34.32 9.81 KPa {3,500 1,000mmH2O}.
- The calorific values of each fuel are based on the following.
Natural Gas(13A) : High/Low Calorific Value 46.05/41.9 MJ/N㎥ {11,000/10,000 kcal/Nm3}
Propane : 101.9/93.8 MJ/Nm3 {24,350/22,400 kcal/Nm3} 50.1/46.4 MJ/N㎥ {11,969/11,089 kcal/kg}
Butane : 133.3/123.5 MJ/Nm3 {31,840/28,400 kcal/Nm3} 51.3/47.5 MJ/N㎥ {12,254/11,353 kcal/kg}
3. Boiler efficiency is based on the lower calorific value, at rated conditions.
4. It includes the following permissible values as unavoidable measurement errors.
- Boiler efficiency measurement error ±1%, Combustion amount (heat input) measurement error ±1.5%
5. If the water softener is to be controlled individually by the boiler control, 220V1¢ power is required.
6. Please understand that some changes may be made without prior notice for product performance improvement.
Product Features
1.Ultra High Efficiency(99%)
By adopting specially processed bulge water tubes and a reverse combustion method, and equipped with a high-performance feed water preheater (STS 304/316) to recover waste exhaust gas heat, 99% efficiency has been achieved.
(Investment cost recoverable within 3 years)
2.Multi-Unit Installation System
By installing multiple once-through scrum boilers to match the minimum load of the application, "supplying only the necessary amount of steam and maximizing the efficiency of each unit," fuel and maintenance costs can be significantly reduced.
3.Equipped with Air Preheater
By supplying combustion air heated to 50~60℃, combustion efficiency is maximized, increasing efficiency by 2~3%.
4.Equipped with Feed Water Preheater
Equipped with a specially processed high-performance feed water preheater (STS304/316), it maximizes the absorption of high-temperature exhaust gas heat generated after combustion, raising the feed water temperature and achieving maximum efficiency.
5.Steam Generation within 5 Minutes
Steam is generated within 5 minutes after boiler operation, reducing preheating loss, saving fuel costs, and allowing immediate operation.
(Approx. 10% fuel saving based on 8 hours/day)
6.Adoption of Distributed Combustion Method
The heat from reverse combustion is distributed through 40~70 passages, preventing local overheating inside the boiler and extending its lifespan.
7.Automatic Concentration Blowdown Device Standard Equipment
By automatically measuring the concentration of boiler water and always discharging only concentrated water above the standard value, the conductivity of the boiler water is maintained within the permissible range, preventing efficiency degradation and priming, and extending lifespan.
8.Perfect After-Sales Management System
Service personnel connected through 29 service networks nationwide are doing their best to ensure customers can use the product safely 24 hours a day.
9.Condensate Neutralization Treatment Device
Equipped with a storage tank containing magnesium rocks, it discharges water conforming to environmental water quality standards (pH 5.8 to 8.6), making it eco-friendly.
(96%~100% or more)
Detailed specification sheets are shown in the product images.