{"product_id":"gs-pressure-reducing-valve-for-pressure-equalization-prevention-129544","title":"G·S Pressure Reducing Valve (For Pressure Equalization Prevention) SI-809","description":"\u003cp\u003e\u003cb\u003eG·S Pressure Reducing Valve for Pressure Equalization Prevention 10kgf\/cm²[1MPa], 20kgf\/cm²[2MPa]\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eBy attaching a separate relief valve to the secondary side of the GS pressure reducing valve body, the rising pressure on the tertiary side is effectively relieved.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eFeatures\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eInstead of configuring a separate bypass pipe and installing a relief valve for fire extinguishing pressure reducing valves, a small-diameter relief valve is installed on the secondary side of the GS pressure reducing valve body to effectively relieve the secondary side pressure rise caused by pressure changes in the system through the relief valve. (Pressure equalization prevention)\u003c\/p\u003e\u003cp\u003eThe relief valve has a built-in strainer to prevent malfunction due to foreign matter and is easy to clean.\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e※ In a fire extinguishing system, if an actual fire does not occur, the secondary side of the pressure reducing valve must always be maintained at a constant pressure.\u003c\/p\u003e\u003cp\u003eHowever, due to the following issues: -pressure changes in the primary (supply) side line of the fire extinguishing water. -pressure rise due to leakage of the pressure reducing valve. -pressure rise that may occur after pressure reducing valve operation.\u003c\/p\u003e\u003cp\u003eDue to these problems, the secondary side pressure cannot be maintained at the set pressure, and after a long time, the pressures on the primary and secondary sides of the pressure reducing valve become equal, entering a static pressure state.\u003c\/p\u003e\u003cp\u003eThis problem can be solved by installing a GS pressure reducing valve with an attached relief valve.\u003c\/p\u003e\u003cp\u003e(※Fire extinguishing tamper switch attached type is produced as an optional specification. Separate price)\u003cbr\u003e(※Products with pressure adjustment range of 13kgf\/㎠ or more have separate pricing.)\u003c\/p\u003e\u003cp\u003eSpecifications\u003c\/p\u003e\u003ctable class=\"pem-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel NO\u003c\/th\u003e\n\u003cth colspan=\"3\"\u003eSI-809\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Fluid\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eCold\/Hot Water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Pressure\u003c\/td\u003e\n\u003ctd\u003eMAX, 1Mpa(10kgf\/㎠)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMAX, 2Mpa(20kgf\/㎠)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Temperature\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e0˚C ~ 80˚C (MAX, 120˚C optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Operating Differential Pressure\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e0.5 kgf\/㎠\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Adjustment Range\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e0.5~5 kgf\/㎠, 4~7 kgf\/㎠ (7~14 kgf\/㎠ optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Control Flow Rate\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e5% of applicable flow rate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Method\u003c\/td\u003e\n\u003ctd\u003eKS Taper Pipe Thread (Rc)\u003c\/td\u003e\n\u003ctd\u003eKS 10K \/ Flange for Water Supply\u003c\/td\u003e\n\u003ctd\u003eKS 20K \/ Flange for Water Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Test\u003c\/td\u003e\n\u003ctd\u003eWater Pressure MAX, 20kgf\/㎠\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eWater Pressure MAX, 40kgf\/㎠\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cbr\u003e\u003cbr\u003e\u003cp\u003eDimensions\u003c\/p\u003e\u003ctable class=\"pem-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eModel NO\u003c\/td\u003e\n\u003ctd colspan=\"4\" rowspan=\"1\"\u003eSI-806,807,809,810\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eSIZE\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eL\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eH\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eH1\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eHole Size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e50A (2\")\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e396.0\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e257.5\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e367.0\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eØ1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e65A (21\/2\")\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e420.0\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e271.0\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e357.0\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eØ1.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e80A (3\")\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e452.0\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e331.0\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e381.0\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eØ1.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e100A (4\")\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e539.0\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e359.5\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e412.0\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eØ1.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e125A (5\")\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e655.0\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e447.0\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e616.0\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eØ1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e150A (6\")\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e746.0\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e517.0\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e603.0\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eØ1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e200A (8\")\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e842.0\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e596.0\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e769.0\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003eØ2.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cem\u003eDetailed specification sheets are shown in the product images.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eCatalogues\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/premiumemart.com\/cdn\/shop\/files\/pem-f-4d659631eb61fc13.pdf\" target=\"_blank\" rel=\"noopener\"\u003e카탈로그-신일밸브-G.S 감압밸브\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"SHINIL VALVE","offers":[{"title":"Default Title","offer_id":58446515142996,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1098\/4649\/5572\/files\/shinil-valve_129544_zyodda.jpg?v=1795191062","url":"https:\/\/premiumemart.com\/products\/gs-pressure-reducing-valve-for-pressure-equalization-prevention-129544","provider":"Premium Emart","version":"1.0","type":"link"}