Geothermal Heat Pump IJS-5SG
New

Geothermal Heat Pump IJS-5SG

* Product Overview

A high-efficiency, eco-friendly system that simultaneously solves heating and cooling by utilizing a geothermal source that maintains a constant temperature throughout the year by burying HDPE pipes underground.

* Product Features

① Stability of heat source: Maintains an average temperature of 15℃ throughout the four seasons
② Economy: High system efficiency (COP: 3.7 ~ 7.0)
③ Minimization of machinery room area
④ Eco-friendliness: No emission of exhaust gas and pollutants
⑤ Simple system for convenient automatic control and operation

* Applications

① Buildings with sufficient surrounding space to bury geothermal heat exchange pipes underground, or buildings with abundant groundwater.
② For places that supply large quantities of hot water (hotels, bathhouses), it can be configured in conjunction with a heat pump system using domestic wastewater heat.
③ When a geothermal heat pump system is applied for cooling/heating supply in agricultural and fishery sectors such as floriculture and aquaculture, it shows excellent energy saving effects.
④ Building cooling / heating or chilled/hot water (Building cooling / heating or chilled/hot water (all places requiring cooling / heating))

* Geothermal Heat Pump Products (IJS-5SG, 30SG, 40SG) Specifications

Item IJS - 5SG IJS - 30SG IJS - 40SG
Performance
(Capacity)
Net
Heating Capacity
KW 18.80 116.66 157.09
USRT 5.35 33.18 44.68
Net
Cooling Capacity
KW 18.53 106.24 138.57
USRT 5.27 30.21 39.41
Power Consumption
(Rated operation)
Heating/Cooling KW 4.2/2.3 29.5/20.3 40.0/26.9
Power Supply 3상 * 380V * 60Hz
External Dimensions
(Shape Dimension)
Length mm 700 1,200 1,700
Height 1,300 1,940 1,940
Width 650 760 1,000
Compressor
(Compressor)
Type * Quantity Hermetic Scroll * 1 Hermetic Scroll * 2
Starting Method Direct On-line Starting
Capacity Control % 0 ~ 100%
Statutory Refrigeration Capacity RT 1.78 12.35 17.18
Refrigerant
(Refrigerant)
Type R - 410A R - 22
Charge Amount Kg 3.5 30 22
Load Side Heat Exchanger
(heat exchanger)
Type Brazed plate type heat exchanger
Circulating Water Flow Rate LPM 19.2 30 35.4
Pressure Drop Kpa 24.5 50.0 56.9
Piping
(IN/OUT)
A 32 50 65
Heat Source Side Heat Exchanger
(heat exchanger)
Type Brazed plate type heat exchanger
Circulating Water Flow Rate LPM 120 350 420
Pressure Drop Kpa 45.5 27.7 37.3
Piping
(IN/OUT)
A 32A 65A
Control
(Control)
Temperature Control 4WAY V/V Proportional Control
Operation Control PCB
Weight Kg 320 780 910
[Conditions] Heating Load side heat exchanger inlet temperature 40℃, heat source side heat exchanger inlet temperature 10℃
Cooling Load side heat exchanger inlet temperature 12℃, heat source side heat exchanger inlet temperature 15℃

■ The performance values of the above product are certified and proven by an accredited certification body (KRAAC), and may vary depending on the conditions of the installation site.
■ The pressure drop of the above product is based on cooling capacity.

Detailed specification sheets are shown in the product images.

Error product group when enable variant picker

Availability: In stock
Geothermal Heat Pump IJS-5SG

Geothermal Heat Pump IJS-5SG

$0.00

Geothermal Heat Pump IJS-5SG: overview and buying guide

The Geothermal Heat Pump IJS-5SG (model IJS-5SG) is made by IL-JIN E-PLUS and listed in our hydraulic · fluid range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.

Frequently asked questions

How much does the Geothermal Heat Pump IJS-5SG cost?

Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.

Can you ship the Geothermal Heat Pump IJS-5SG to my country?

Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.

Is this a genuine IL-JIN E-PLUS product?

We purchase directly from IL-JIN E-PLUS or its authorised channels and confirm the model and specifications with the manufacturer before ordering.

What is the minimum order quantity?

For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.

* Product Overview

A high-efficiency, eco-friendly system that simultaneously solves heating and cooling by utilizing a geothermal source that maintains a constant temperature throughout the year by burying HDPE pipes underground.

* Product Features

① Stability of heat source: Maintains an average temperature of 15℃ throughout the four seasons
② Economy: High system efficiency (COP: 3.7 ~ 7.0)
③ Minimization of machinery room area
④ Eco-friendliness: No emission of exhaust gas and pollutants
⑤ Simple system for convenient automatic control and operation

* Applications

① Buildings with sufficient surrounding space to bury geothermal heat exchange pipes underground, or buildings with abundant groundwater.
② For places that supply large quantities of hot water (hotels, bathhouses), it can be configured in conjunction with a heat pump system using domestic wastewater heat.
③ When a geothermal heat pump system is applied for cooling/heating supply in agricultural and fishery sectors such as floriculture and aquaculture, it shows excellent energy saving effects.
④ Building cooling / heating or chilled/hot water (Building cooling / heating or chilled/hot water (all places requiring cooling / heating))

* Geothermal Heat Pump Products (IJS-5SG, 30SG, 40SG) Specifications

Item IJS - 5SG IJS - 30SG IJS - 40SG
Performance
(Capacity)
Net
Heating Capacity
KW 18.80 116.66 157.09
USRT 5.35 33.18 44.68
Net
Cooling Capacity
KW 18.53 106.24 138.57
USRT 5.27 30.21 39.41
Power Consumption
(Rated operation)
Heating/Cooling KW 4.2/2.3 29.5/20.3 40.0/26.9
Power Supply 3상 * 380V * 60Hz
External Dimensions
(Shape Dimension)
Length mm 700 1,200 1,700
Height 1,300 1,940 1,940
Width 650 760 1,000
Compressor
(Compressor)
Type * Quantity Hermetic Scroll * 1 Hermetic Scroll * 2
Starting Method Direct On-line Starting
Capacity Control % 0 ~ 100%
Statutory Refrigeration Capacity RT 1.78 12.35 17.18
Refrigerant
(Refrigerant)
Type R - 410A R - 22
Charge Amount Kg 3.5 30 22
Load Side Heat Exchanger
(heat exchanger)
Type Brazed plate type heat exchanger
Circulating Water Flow Rate LPM 19.2 30 35.4
Pressure Drop Kpa 24.5 50.0 56.9
Piping
(IN/OUT)
A 32 50 65
Heat Source Side Heat Exchanger
(heat exchanger)
Type Brazed plate type heat exchanger
Circulating Water Flow Rate LPM 120 350 420
Pressure Drop Kpa 45.5 27.7 37.3
Piping
(IN/OUT)
A 32A 65A
Control
(Control)
Temperature Control 4WAY V/V Proportional Control
Operation Control PCB
Weight Kg 320 780 910
[Conditions] Heating Load side heat exchanger inlet temperature 40℃, heat source side heat exchanger inlet temperature 10℃
Cooling Load side heat exchanger inlet temperature 12℃, heat source side heat exchanger inlet temperature 15℃

■ The performance values of the above product are certified and proven by an accredited certification body (KRAAC), and may vary depending on the conditions of the installation site.
■ The pressure drop of the above product is based on cooling capacity.

Detailed specification sheets are shown in the product images.