{"product_id":"gas-detector-55001","title":"Gas Detector DA-800 Series","description":"\u003cp\u003eDA-800 detects various combustible \u0026amp; toxic gases leaked from industrial areas for gas producers, gas users, gas reservoirs, gas by-producers, and so on, in order to prevent any accidents in advance. Built-in micro pump for gas sampling enables effective gas detection especially for the environment where diffusion type gas detectors cannot be used. DA-800 converts digital signal into the 4-20mA standard current output signal which can be transmitted to various devices such as PLC, DDC, or recorder to build comprehensive gas monitoring system. Also, DA-800 provides RS-485 communication signal and alarm relay contact. DC 4-20mA standard output signal realizes max 2500m long distance output signal transmission and RS-485 communication signal realizes max 1000m long distance signal transmission. \u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e[ Features ] \u003c\/strong\u003e\u003cbr\u003e  \u003cbr\u003e ㆍ LCD display with Back Light  \u003cbr\u003e ㆍ Built-in HD(high dissolution) A\/D converter for accurate output signal.  \u003cbr\u003e ㆍ Multi Signal Output  \u003cbr\u003e     DC 4-20mA, 2 step-relay contact, \u0026amp; RS-485(option) provides best networking with all kinds of devices \u0026amp; equipments.  \u003cbr\u003e ㆍ 4-20mA Transmitter \u003cbr\u003e     4-20mA output enables stable and long distance (maximum 2.5km) signal transmission. \u003cbr\u003e ㆍ RS-485 \u003cbr\u003e     RS-485 enables stables stable and long distance (maximum 1.2km) signal communication. \u003cbr\u003e ㆍ Alarm output \u003cbr\u003e     SPST 2 step relay contacts (AL1\/AL2). \u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e[ Specification ]\u003c\/strong\u003e  \u003c\/p\u003e \u003ctable class=\"pem-spec\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd colspan=\"2\"\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eGas sampling\u003c\/td\u003e \u003ctd\u003eSuction type\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDensity display and unit\u003c\/td\u003e \u003ctd\u003eBuilt-in LCD Display - PPM, %LEL, or % set by user\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInput power\u003c\/td\u003e \u003ctd\u003eDC 18-30V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eExplosion proof\u003c\/td\u003e \u003ctd\u003eEx d IIB+H2\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTarget gas\u003c\/td\u003e \u003ctd\u003ePlease refer to the list.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDetection principle\u003c\/td\u003e \u003ctd\u003eCatalytic, Electro-Chemical, or NDIR\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSuction flow rate\u003c\/td\u003e \u003ctd\u003e0 ~ 1000ml \/ min\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSuction distance\u003c\/td\u003e \u003ctd\u003eWithin 100m\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMeasurement range\u003c\/td\u003e \u003ctd\u003ePlease refer to the list\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAccuracy\u003c\/td\u003e \u003ctd\u003e≤2% \/full scale\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eResponse time\u003c\/td\u003e \u003ctd\u003ewithin 20 seconds, 90%\/full scale\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSensor calibration\u003c\/td\u003e \u003ctd\u003eAuto calibration with magnetic switch\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUser programming\u003c\/td\u003e \u003ctd\u003eCalibration density \u0026amp; Measurement range\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWiring\u003c\/td\u003e \u003ctd\u003eCVVS \u0026amp; CVVSB 1.25sq*3wire\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eOutput signal\u003c\/td\u003e \u003ctd\u003e4-20mA DC\/F.S \/\/ RS-485(MODBUS-RTU)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAlarm output\u003c\/td\u003e \u003ctd\u003e2 step (HIGH\/LOW) alarm relay contact\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eOperation temperature\u003c\/td\u003e \u003ctd\u003e-10℃ ~ 50℃\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eOperation humidity\u003c\/td\u003e \u003ctd\u003e5 ~ 95%RH (non-condensing)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWire conduit\u003c\/td\u003e \u003ctd\u003e1\/2” or 3\/4” PF, NPT\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eHousing material\u003c\/td\u003e \u003ctd\u003eCast Aluminum Alloy\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMounting\u003c\/td\u003e \u003ctd\u003eWall or pipe mounting\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\u003cp\u003e\u003cem\u003eDetailed specification sheets are shown in the product images.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eCatalogues\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/premiumemart.com\/cdn\/shop\/files\/pem-f-13069ce5d36f1e80.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDA-800 Spec\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/premiumemart.com\/cdn\/shop\/files\/pem-f-50c4cb48ec89bf4e.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDA-800 Spec\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GASDNA","offers":[{"title":"Default Title","offer_id":58447072985428,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1098\/4649\/5572\/files\/gasdna_55001_pinbwe.jpg?v=1795192381","url":"https:\/\/premiumemart.com\/products\/gas-detector-55001","provider":"Premium Emart","version":"1.0","type":"link"}