Gas Detector DA-750 Series
DA-750 detects leakage of various toxic or combustible gases leaked from industrial areas for gas producers, gas users, gas reservoirs, gas by-producers, and so on, in order to prevent any accidents in advance. Built-in micro pump suctions gas continuously which is effective gas sampling especially for closed area. DA-750 converts digital signal into the 4-20㎃ standard current signal for output signal which can be transmitted to various external devices such as PLC, DDC, RECODER, and so on to construct the gas monitoring system more extensive as well as more comprehensive. DA-750 provides RS-485 communication signal and gas leakage alarm signal by relay contact output. Besides, DA-750 has DC 4-20mA standard output which realizes max 2500m long distance output signal transmission from sensor to receiver and RS-485 communication signal which realizes max 1000m long distance signal transmission.
[ Features ]
ㆍ Auto-Suction Type
Built-in micro pump suctions gas continuously which is effective gas sampling especially for closed area.
ㆍ LCD Display with Back-Light
Isolation Circuit
ㆍBuilt-in isolation circuit prevents electrical noise to secure stable sensor operation.
ㆍ 4-20mA Transmitter
4-20mA output enables stable and long distance (maximum 2.5km) signal transmission.
ㆍ RS-485
RS-485 enables stables stable and long distance (maximum 1.2km) signal communication.
ㆍ Alarm output
SPST 2 step relay contacts (AL1/AL2).
[ Specification ]
| Detection principle | Catalytic, electro-chemical, NDIR, or PID |
| Gas sampling | Suction Type |
| Input power | DC 20~24V |
| Sample gas volume | 1.0 Liter/min ~ 2.5 Liter/min |
| Accuracy | ≤2% /full scale |
| Output signal | DC 4-20㎃ / full scale |
| Memory | 4,000 records |
| Density indication | LCD Display - PPM, %LEL, %, or PPb |
| Alarm | AL1 Alarm – AL1 LED (RED) AL2 Alarm – AL2 LED (RED) |
| Setting of alarm value | AL1/AL2 2stages Alarm-User can optionally set. |
| Alarm delay time | 0~99 seconds with user adjustable |
| Alarm clearing | Manually or automatically |
| Alarm output | 2 step alarm relay contact (AL1/AL2) |
| Operating temperature | -10℃ ~ 50℃ |
| Operating humidity | 5 ~ 95%RH (Non-Condensing) |
| How to install | Wall Mounting Type |
| Signal cable | CVVS & CVVSB 1.25sp*3 Wire-Shield Type |
| Gas inhaling | 6Ø Tube |
| Output option | RS-485 |
Detailed specification sheets are shown in the product images.
Catalogues
Gas Detector DA-750 Series
Gas Detector DA-750 Series: overview and buying guide
The Gas Detector DA-750 Series (model DA-750 Series) is made by GASDNA and listed in our test · measurement range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.
Frequently asked questions
How much does the Gas Detector DA-750 Series cost?
Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.
Can you ship the Gas Detector DA-750 Series to my country?
Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.
Is this a genuine GASDNA product?
We purchase directly from GASDNA or its authorised channels and confirm the model and specifications with the manufacturer before ordering.
What is the minimum order quantity?
For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.
DA-750 detects leakage of various toxic or combustible gases leaked from industrial areas for gas producers, gas users, gas reservoirs, gas by-producers, and so on, in order to prevent any accidents in advance. Built-in micro pump suctions gas continuously which is effective gas sampling especially for closed area. DA-750 converts digital signal into the 4-20㎃ standard current signal for output signal which can be transmitted to various external devices such as PLC, DDC, RECODER, and so on to construct the gas monitoring system more extensive as well as more comprehensive. DA-750 provides RS-485 communication signal and gas leakage alarm signal by relay contact output. Besides, DA-750 has DC 4-20mA standard output which realizes max 2500m long distance output signal transmission from sensor to receiver and RS-485 communication signal which realizes max 1000m long distance signal transmission.
[ Features ]
ㆍ Auto-Suction Type
Built-in micro pump suctions gas continuously which is effective gas sampling especially for closed area.
ㆍ LCD Display with Back-Light
Isolation Circuit
ㆍBuilt-in isolation circuit prevents electrical noise to secure stable sensor operation.
ㆍ 4-20mA Transmitter
4-20mA output enables stable and long distance (maximum 2.5km) signal transmission.
ㆍ RS-485
RS-485 enables stables stable and long distance (maximum 1.2km) signal communication.
ㆍ Alarm output
SPST 2 step relay contacts (AL1/AL2).
[ Specification ]
| Detection principle | Catalytic, electro-chemical, NDIR, or PID |
| Gas sampling | Suction Type |
| Input power | DC 20~24V |
| Sample gas volume | 1.0 Liter/min ~ 2.5 Liter/min |
| Accuracy | ≤2% /full scale |
| Output signal | DC 4-20㎃ / full scale |
| Memory | 4,000 records |
| Density indication | LCD Display - PPM, %LEL, %, or PPb |
| Alarm | AL1 Alarm – AL1 LED (RED) AL2 Alarm – AL2 LED (RED) |
| Setting of alarm value | AL1/AL2 2stages Alarm-User can optionally set. |
| Alarm delay time | 0~99 seconds with user adjustable |
| Alarm clearing | Manually or automatically |
| Alarm output | 2 step alarm relay contact (AL1/AL2) |
| Operating temperature | -10℃ ~ 50℃ |
| Operating humidity | 5 ~ 95%RH (Non-Condensing) |
| How to install | Wall Mounting Type |
| Signal cable | CVVS & CVVSB 1.25sp*3 Wire-Shield Type |
| Gas inhaling | 6Ø Tube |
| Output option | RS-485 |