Gas Detector DA-750 Series
Gas Detector DA-750 Series
New
Gas Detector DA-750 Series
Gas Detector DA-750 Series

Gas Detector DA-750 Series

DA-750 detects leakage of various toxic or combustible gases leaked from industrial areas for gas producers, gas users, gas reservoirs, gas by-producers, and so on, in order to prevent any accidents in advance. Built-in micro pump suctions gas continuously which is effective gas sampling especially for closed area. DA-750 converts digital signal into the 4-20㎃ standard current signal for output signal which can be transmitted to various external devices such as PLC, DDC, RECODER, and so on to construct the gas monitoring system more extensive as well as more comprehensive. DA-750 provides RS-485 communication signal and gas leakage alarm signal by relay contact output. Besides, DA-750 has DC 4-20mA standard output which realizes max 2500m long distance output signal transmission from sensor to receiver and RS-485 communication signal which realizes max 1000m long distance signal transmission. 

[ Features ] 

ㆍ Auto-Suction Type  
    Built-in micro pump suctions gas continuously which is effective gas sampling especially for closed area. 
ㆍ LCD Display with Back-Light  
     Isolation Circuit  
ㆍBuilt-in isolation circuit prevents electrical noise to secure stable sensor operation.  
ㆍ 4-20mA Transmitter 
    4-20mA output enables stable and long distance (maximum 2.5km) signal transmission. 
ㆍ RS-485 
    RS-485 enables stables stable and long distance (maximum 1.2km) signal communication. 
ㆍ Alarm output 
    SPST 2 step relay contacts (AL1/AL2). 

[ Specification ]  

 
Detection principle Catalytic, electro-chemical, NDIR, or PID
Gas sampling Suction Type
Input power DC 20~24V
Sample gas volume 1.0 Liter/min ~ 2.5 Liter/min
Accuracy ≤2% /full scale
Output signal DC 4-20㎃ / full scale
Memory 4,000 records
Density indication LCD Display - PPM, %LEL, %, or PPb
Alarm AL1 Alarm – AL1 LED (RED)
AL2 Alarm – AL2 LED (RED)
Setting of alarm value AL1/AL2 2stages Alarm-User can optionally set.
Alarm delay time 0~99 seconds with user adjustable
Alarm clearing Manually or automatically
Alarm output 2 step alarm relay contact (AL1/AL2)
Operating temperature -10℃ ~ 50℃
Operating humidity 5 ~ 95%RH (Non-Condensing)
How to install Wall Mounting Type
Signal cable CVVS & CVVSB 1.25sp*3 Wire-Shield Type
Gas inhaling 6Ø Tube
Output option RS-485

Detailed specification sheets are shown in the product images.

Catalogues

Error product group when enable variant picker

Availability: In stock
Categories: Test · Measurement
Gas Detector DA-750 Series

Gas Detector DA-750 Series

$0.00

Gas Detector DA-750 Series: overview and buying guide

The Gas Detector DA-750 Series (model DA-750 Series) is made by GASDNA and listed in our test · measurement range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.

Frequently asked questions

How much does the Gas Detector DA-750 Series cost?

Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.

Can you ship the Gas Detector DA-750 Series to my country?

Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.

Is this a genuine GASDNA product?

We purchase directly from GASDNA or its authorised channels and confirm the model and specifications with the manufacturer before ordering.

What is the minimum order quantity?

For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.

DA-750 detects leakage of various toxic or combustible gases leaked from industrial areas for gas producers, gas users, gas reservoirs, gas by-producers, and so on, in order to prevent any accidents in advance. Built-in micro pump suctions gas continuously which is effective gas sampling especially for closed area. DA-750 converts digital signal into the 4-20㎃ standard current signal for output signal which can be transmitted to various external devices such as PLC, DDC, RECODER, and so on to construct the gas monitoring system more extensive as well as more comprehensive. DA-750 provides RS-485 communication signal and gas leakage alarm signal by relay contact output. Besides, DA-750 has DC 4-20mA standard output which realizes max 2500m long distance output signal transmission from sensor to receiver and RS-485 communication signal which realizes max 1000m long distance signal transmission. 

[ Features ] 

ㆍ Auto-Suction Type  
    Built-in micro pump suctions gas continuously which is effective gas sampling especially for closed area. 
ㆍ LCD Display with Back-Light  
     Isolation Circuit  
ㆍBuilt-in isolation circuit prevents electrical noise to secure stable sensor operation.  
ㆍ 4-20mA Transmitter 
    4-20mA output enables stable and long distance (maximum 2.5km) signal transmission. 
ㆍ RS-485 
    RS-485 enables stables stable and long distance (maximum 1.2km) signal communication. 
ㆍ Alarm output 
    SPST 2 step relay contacts (AL1/AL2). 

[ Specification ]  

 
Detection principle Catalytic, electro-chemical, NDIR, or PID
Gas sampling Suction Type
Input power DC 20~24V
Sample gas volume 1.0 Liter/min ~ 2.5 Liter/min
Accuracy ≤2% /full scale
Output signal DC 4-20㎃ / full scale
Memory 4,000 records
Density indication LCD Display - PPM, %LEL, %, or PPb
Alarm AL1 Alarm – AL1 LED (RED)
AL2 Alarm – AL2 LED (RED)
Setting of alarm value AL1/AL2 2stages Alarm-User can optionally set.
Alarm delay time 0~99 seconds with user adjustable
Alarm clearing Manually or automatically
Alarm output 2 step alarm relay contact (AL1/AL2)
Operating temperature -10℃ ~ 50℃
Operating humidity 5 ~ 95%RH (Non-Condensing)
How to install Wall Mounting Type
Signal cable CVVS & CVVSB 1.25sp*3 Wire-Shield Type
Gas inhaling 6Ø Tube
Output option RS-485

Detailed specification sheets are shown in the product images.

Catalogues