Gas Detector DA-50 Series
Gas Detector DA-50 Series
New
Gas Detector DA-50 Series
Gas Detector DA-50 Series

Gas Detector DA-50 Series

DA-50 detects various combustible & toxic gases leaked from industrial areas for gas producers,gas users, gas reservoirs, gas by-producers, and so on, in order to prevent any accidents in advance.

DA-50 converts digital signal into the 4-20㎃ standard current signal for output signal which can be transmitted to various external devices such as PLC, DDC, RECODER, and so on.
Using these functions, you can easily construct the gas monitoring system more extensive as well as more comprehensive.

DA-50 provides RS-485 communication signal and gas leakage alarm signal by relay contact output.
Besides, DA-50 has DC 4-20mA standard output which realizes max 2,500m long distance output signal transmission from sensor to receiver and RS-485 communication signal which realizes max 1000m long distance signal transmission.

[ Features ]

ㆍ LCD display with Back Light
ㆍ Multi Signal Output
DC 4-20mA, 2 step-relay contact, & RS-485(option) – provides best networking with all kinds of devices & equipments.
ㆍ 4-20mA Transmitter
4-20mA output enables stable and long distance (maximum 2.5km) signal transmission.
ㆍ RS-485
RS-485 enables stables stable and long distance (maximum 1.2km) signal communication.
ㆍ Alarm output
SPST 2 step relay contacts (AL1/AL2).

[ Specification ]

Detection principle Catalytic, electro-chemical, NDIR, or PID
Gas sampling Diffusion
Target gas Refer to the list
Density indication LCD display - PPM, %LEL, or %
Response time within 20 seconds, 90%/full scale
Accuracy ≤2% /full scale
Sensor calibration Calibration with switch
Sensor parallax Zero – ≤ ±1% / 6 months, Span -≤ ±1% / 6 months
User programmable Calibration density, detection range
Input power DC 20 ~ 30V
Output power 4 ~ 20mA / full scale – maximum 2.5km long signal transmission
Communication RS-485 – maximum 1.2km long signal transmission
with GasDNA’s own protocol
Operating temperature and humidity -20℃~50℃, 5~95% RH (non-condensing)
Signal wire CVVS & CVVSB 1.25sq x 3 wires - shield type
Alarm release Manual or Automatic
Mounting Wall or pipe mounting
Housing Polycarbonate
Alarm output 2 step- relay contacts (AL1/AL2)

Detailed specification sheets are shown in the product images.

Catalogues

Error product group when enable variant picker

Availability: In stock
Categories: Test · Measurement
Gas Detector DA-50 Series

Gas Detector DA-50 Series

$0.00

Gas Detector DA-50 Series: overview and buying guide

The Gas Detector DA-50 Series (model DA-50 Series) is made by GASDNA and listed in our test · measurement range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.

Frequently asked questions

How much does the Gas Detector DA-50 Series cost?

Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.

Can you ship the Gas Detector DA-50 Series to my country?

Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.

Is this a genuine GASDNA product?

We purchase directly from GASDNA or its authorised channels and confirm the model and specifications with the manufacturer before ordering.

What is the minimum order quantity?

For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.

DA-50 detects various combustible & toxic gases leaked from industrial areas for gas producers,gas users, gas reservoirs, gas by-producers, and so on, in order to prevent any accidents in advance.

DA-50 converts digital signal into the 4-20㎃ standard current signal for output signal which can be transmitted to various external devices such as PLC, DDC, RECODER, and so on.
Using these functions, you can easily construct the gas monitoring system more extensive as well as more comprehensive.

DA-50 provides RS-485 communication signal and gas leakage alarm signal by relay contact output.
Besides, DA-50 has DC 4-20mA standard output which realizes max 2,500m long distance output signal transmission from sensor to receiver and RS-485 communication signal which realizes max 1000m long distance signal transmission.

[ Features ]

ㆍ LCD display with Back Light
ㆍ Multi Signal Output
DC 4-20mA, 2 step-relay contact, & RS-485(option) – provides best networking with all kinds of devices & equipments.
ㆍ 4-20mA Transmitter
4-20mA output enables stable and long distance (maximum 2.5km) signal transmission.
ㆍ RS-485
RS-485 enables stables stable and long distance (maximum 1.2km) signal communication.
ㆍ Alarm output
SPST 2 step relay contacts (AL1/AL2).

[ Specification ]

Detection principle Catalytic, electro-chemical, NDIR, or PID
Gas sampling Diffusion
Target gas Refer to the list
Density indication LCD display - PPM, %LEL, or %
Response time within 20 seconds, 90%/full scale
Accuracy ≤2% /full scale
Sensor calibration Calibration with switch
Sensor parallax Zero – ≤ ±1% / 6 months, Span -≤ ±1% / 6 months
User programmable Calibration density, detection range
Input power DC 20 ~ 30V
Output power 4 ~ 20mA / full scale – maximum 2.5km long signal transmission
Communication RS-485 – maximum 1.2km long signal transmission
with GasDNA’s own protocol
Operating temperature and humidity -20℃~50℃, 5~95% RH (non-condensing)
Signal wire CVVS & CVVSB 1.25sq x 3 wires - shield type
Alarm release Manual or Automatic
Mounting Wall or pipe mounting
Housing Polycarbonate
Alarm output 2 step- relay contacts (AL1/AL2)

Detailed specification sheets are shown in the product images.

Catalogues