{"product_id":"gas-detector-54997","title":"Gas Detector DA-500 Series","description":"\u003cp\u003eDA-500 detects various combustible \u0026amp; toxic gases leaked from industrial areas for gas producers, gas users, gas reservoirs, gas by-producers, and so on, in order to prevent any accidents in advance. DA-500 converts digital signal into the 4-20mA standard current output signal which can be transmitted to various devices such as PLC, DDC, or recorder to build comprehensive gas monitoring system. Also, DA-500 provides RS-485 communication signal and alarm relay contact. DC 4-20mA standard output signal realizes max 2500m long distance output signal transmission and RS-485 communication signal realizes max 1000m long distance signal transmission.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e[ Features ]\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eㆍ Auto-calibration without opening cover You only have to touch cover window using magnetic bar. It is quite useful for the corrective work in the explosive area. \u003cbr\u003e ㆍ LCD display with back light \u003cbr\u003e ㆍ Built-in HD(high dissolution) A\/D converter for accurate output signal. \u003cbr\u003e ㆍ Multi signal output \u003cbr\u003e DC 4-20mA, 2 step-relay contact, \u0026amp; RS-485(option) – provides best networking with all kinds of devices \u0026amp; equipments. \u003cbr\u003e ㆍ 4-20mA transmitter \u003cbr\u003e 4-20mA output enables stable and long distance (maximum 2.5km) signal transmission. \u003cbr\u003e ㆍ RS-485 \u003cbr\u003e RS-485 enables stables stable and long distance (maximum 1.2km) signal communication. \u003cbr\u003e ㆍ Alarm output \u003cbr\u003e SPST 2 step relay contacts (AL1\/AL2). \u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e[ Specification ]\u003c\/strong\u003e \u003c\/p\u003e \u003ctable class=\"pem-spec\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd colspan=\"2\"\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDetection principle\u003c\/td\u003e \u003ctd\u003eCatalytic, Electro-Chemical, TCD or NDIR\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBuilt-in display\u003c\/td\u003e \u003ctd\u003e2-lines x 8-characters LCD with back light\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eGas sampling\u003c\/td\u003e \u003ctd\u003eDiffusion type\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTarget gas\u003c\/td\u003e \u003ctd\u003ePlease refer to the target gas list.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMeasurement range\u003c\/td\u003e \u003ctd\u003e0 ~ 100 %LEL, 0~10,000ppm. 0~100% VOL\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eResponse time\u003c\/td\u003e \u003ctd\u003ewithin 20 seconds, 90%\/full scale\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAccuracy\u003c\/td\u003e \u003ctd\u003e≤2% \/full scale\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSensor displacement\u003c\/td\u003e \u003ctd\u003eZero – ≤±2%LEL \/ 6 month, span -≤±2%LEL \/ 6 month\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInput power\u003c\/td\u003e \u003ctd\u003eDC 20 ~ 30V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eOutput power\u003c\/td\u003e \u003ctd\u003e4 ~ 20mA\/Full Scale - 2.5km transmission\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eOperating temp.\u0026amp; humidity\u003c\/td\u003e \u003ctd\u003e-20℃~ 60℃, 5 ~ 95% RH (Non-condensing)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSignal cable\u003c\/td\u003e \u003ctd\u003eCVVS \u0026amp; CVVSB 1.25sq x 3 wire - shield type\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWire conduit\u003c\/td\u003e \u003ctd\u003e1\/2\" or 3\/4\" PF, NPT\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInstallation type\u003c\/td\u003e \u003ctd\u003eWall or Pipe Mounting\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eExterior material\u003c\/td\u003e \u003ctd\u003eCast Aluminum Alloy\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eExplosion-proof\u003c\/td\u003e \u003ctd\u003eEx d IIC T5\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eOutput\u003c\/td\u003e \u003ctd\u003e2 step- relay contact (ALARM-1\/ALARM-2)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCommunication output\u003c\/td\u003e \u003ctd\u003eRS-485 communication output(option)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSensor operation period\u003c\/td\u003e \u003ctd\u003e5 years (in air)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSensor warranty period\u003c\/td\u003e \u003ctd\u003e1 year\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd colspan=\"2\"\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\u003cp\u003e\u003cem\u003eDetailed specification sheets are shown in the product images.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eCatalogues\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/premiumemart.com\/cdn\/shop\/files\/pem-f-45bb1ad02ab04244.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDA-500 Spec\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/premiumemart.com\/cdn\/shop\/files\/pem-f-fef4843edef39878.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDA-500 Spec\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GASDNA","offers":[{"title":"Default Title","offer_id":58447071543636,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1098\/4649\/5572\/files\/gasdna_54997_xfywvv.jpg?v=1795192379","url":"https:\/\/premiumemart.com\/products\/gas-detector-54997","provider":"Premium Emart","version":"1.0","type":"link"}