DA-500 detects various combustible & toxic gases leaked from industrial areas for gas producers, gas users, gas reservoirs, gas by-producers, and so on, in order to prevent any accidents in advance. DA-500 converts digital signal into the 4-20mA standard current output signal which can be transmitted to various devices such as PLC, DDC, or recorder to build comprehensive gas monitoring system. Also, DA-500 provides RS-485 communication signal and alarm relay contact. DC 4-20mA standard output signal realizes max 2500m long distance output signal transmission and RS-485 communication signal realizes max 1000m long distance signal transmission.

[ Features ]

ㆍ Auto-calibration without opening cover You only have to touch cover window using magnetic bar. It is quite useful for the corrective work in the explosive area.
ㆍ LCD display with back light
ㆍ Built-in HD(high dissolution) A/D converter for accurate output signal.
ㆍ Multi signal output
DC 4-20mA, 2 step-relay contact, & RS-485(option) – provides best networking with all kinds of devices & equipments.
ㆍ 4-20mA transmitter
4-20mA output enables stable and long distance (maximum 2.5km) signal transmission.
ㆍ RS-485
RS-485 enables stables stable and long distance (maximum 1.2km) signal communication.
ㆍ Alarm output
SPST 2 step relay contacts (AL1/AL2).

[ Specification ]

Detection principle Catalytic, Electro-Chemical, TCD or NDIR
Built-in display 2-lines x 8-characters LCD with back light
Gas sampling Diffusion type
Target gas Please refer to the target gas list.
Measurement range 0 ~ 100 %LEL, 0~10,000ppm. 0~100% VOL
Response time within 20 seconds, 90%/full scale
Accuracy ≤2% /full scale
Sensor displacement Zero – ≤±2%LEL / 6 month, span -≤±2%LEL / 6 month
Input power DC 20 ~ 30V
Output power 4 ~ 20mA/Full Scale - 2.5km transmission
Operating temp.& humidity -20℃~ 60℃, 5 ~ 95% RH (Non-condensing)
Signal cable CVVS & CVVSB 1.25sq x 3 wire - shield type
Wire conduit 1/2" or 3/4" PF, NPT
Installation type Wall or Pipe Mounting
Exterior material Cast Aluminum Alloy
Explosion-proof Ex d IIC T5
Output 2 step- relay contact (ALARM-1/ALARM-2)
Communication output RS-485 communication output(option)
Sensor operation period 5 years (in air)
Sensor warranty period 1 year

Detailed specification sheets are shown in the product images.

Catalogues

Error product group when enable variant picker

Availability: In stock
Categories: Test · Measurement
Gas Detector DA-500 Series

Gas Detector DA-500 Series

$0.00

Gas Detector DA-500 Series: overview and buying guide

The Gas Detector DA-500 Series (model DA-500 Series) is made by GASDNA and listed in our test · measurement range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.

Frequently asked questions

How much does the Gas Detector DA-500 Series cost?

Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.

Can you ship the Gas Detector DA-500 Series to my country?

Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.

Is this a genuine GASDNA product?

We purchase directly from GASDNA or its authorised channels and confirm the model and specifications with the manufacturer before ordering.

What is the minimum order quantity?

For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.

DA-500 detects various combustible & toxic gases leaked from industrial areas for gas producers, gas users, gas reservoirs, gas by-producers, and so on, in order to prevent any accidents in advance. DA-500 converts digital signal into the 4-20mA standard current output signal which can be transmitted to various devices such as PLC, DDC, or recorder to build comprehensive gas monitoring system. Also, DA-500 provides RS-485 communication signal and alarm relay contact. DC 4-20mA standard output signal realizes max 2500m long distance output signal transmission and RS-485 communication signal realizes max 1000m long distance signal transmission.

[ Features ]

ㆍ Auto-calibration without opening cover You only have to touch cover window using magnetic bar. It is quite useful for the corrective work in the explosive area.
ㆍ LCD display with back light
ㆍ Built-in HD(high dissolution) A/D converter for accurate output signal.
ㆍ Multi signal output
DC 4-20mA, 2 step-relay contact, & RS-485(option) – provides best networking with all kinds of devices & equipments.
ㆍ 4-20mA transmitter
4-20mA output enables stable and long distance (maximum 2.5km) signal transmission.
ㆍ RS-485
RS-485 enables stables stable and long distance (maximum 1.2km) signal communication.
ㆍ Alarm output
SPST 2 step relay contacts (AL1/AL2).

[ Specification ]

Detection principle Catalytic, Electro-Chemical, TCD or NDIR
Built-in display 2-lines x 8-characters LCD with back light
Gas sampling Diffusion type
Target gas Please refer to the target gas list.
Measurement range 0 ~ 100 %LEL, 0~10,000ppm. 0~100% VOL
Response time within 20 seconds, 90%/full scale
Accuracy ≤2% /full scale
Sensor displacement Zero – ≤±2%LEL / 6 month, span -≤±2%LEL / 6 month
Input power DC 20 ~ 30V
Output power 4 ~ 20mA/Full Scale - 2.5km transmission
Operating temp.& humidity -20℃~ 60℃, 5 ~ 95% RH (Non-condensing)
Signal cable CVVS & CVVSB 1.25sq x 3 wire - shield type
Wire conduit 1/2" or 3/4" PF, NPT
Installation type Wall or Pipe Mounting
Exterior material Cast Aluminum Alloy
Explosion-proof Ex d IIC T5
Output 2 step- relay contact (ALARM-1/ALARM-2)
Communication output RS-485 communication output(option)
Sensor operation period 5 years (in air)
Sensor warranty period 1 year

Detailed specification sheets are shown in the product images.