fume hood SNFH-1000
Fume Hood / SNFH-Series
Specifications
Construction |
Intrior |
Phenolic resin Laminate |
|---|---|---|
Exterior |
Steel Plate with Powder Coating |
|
Door |
Safety cemented glass |
|
Blower Motor |
Built-in Sirocco Type |
|
Plate in Workzone |
Phenolic resin Laminate |
|
Electrical Outlets |
AC 220V 2ea |
|
Utility |
Water Cock / Air Cock / Gas Cock (option) |
|
Controller |
L.C.D Display |
|
Supply Voltage & Frequency |
AC220V. 50/60Hz |
|
GENERAL SPECIFICATIONS |
SNFH - 1000 |
SNFH - 2011 |
SNFH - 2012 |
SNFH - 2013 |
|---|---|---|---|---|
External Dimension |
1000x790x2300(mm) |
1200x790x2300(mm) |
1500x790x2300(mm) |
1800x790x2300(mm) |
Internal Workzone Dimension (L x D x W) |
810x535x1140 |
1010x535x1140 |
1310x535x1140 |
1610x535x1140 |
Duct |
150∅ |
200∅ |
200∅ |
200∅ or 250∅ |
Power Consumption |
175W |
280W |
280W |
280W or 470W |
Product Name
Model |
SNFH - 1000 |
SNFH - 2011 |
SNFH - 2012 |
|---|---|---|---|
G2B Identification number |
23067289 |
23067290 |
23067291 |
S2B Item number |
201902148398737 |
201902148398779 |
201902148398849 |
Features
Excellent fire resistance and durability due to the use of phenolic laminate for the interior material .
Real-time monitoring of wind speed status and alarm sound when wind speed falls below the set value via the application of a wind speed controller
Safely dispose of waste reagents after experiments by installing a waste reagent treatment facility
Useful for storing acidic solvents, flammable organic compounds, etc. by installing a safety cabinet in the submerged space .
Applying a sliding mechanism to the bottom of the upper and lower sliding doors facilitates testing and minimizes the impact on face airflow velocity.
Controller for face wind speed control
Lamp and blower on/off function
Checking and monitoring wind speed conditions
Automatic face wind speed control equipped with a VAV sensor module
Warning sound when wind speed falls below the set value
door
Sliding mechanism adopted at the bottom of the RAM top-and-bottom sliding door
Waste reagent treatment device
Installed facilities to handle waste reagents more safely
Detailed specification sheets are shown in the product images.
fume hood SNFH-1000
fume hood SNFH-1000: overview and buying guide
The fume hood SNFH-1000 (model SNFH-1000) is made by Shinsaeng and listed in our test · measurement range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.
Frequently asked questions
How much does the fume hood SNFH-1000 cost?
Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.
Can you ship the fume hood SNFH-1000 to my country?
Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.
Is this a genuine Shinsaeng product?
We purchase directly from Shinsaeng or its authorised channels and confirm the model and specifications with the manufacturer before ordering.
What is the minimum order quantity?
For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.
Fume Hood / SNFH-Series
Specifications
Construction |
Intrior |
Phenolic resin Laminate |
|---|---|---|
Exterior |
Steel Plate with Powder Coating |
|
Door |
Safety cemented glass |
|
Blower Motor |
Built-in Sirocco Type |
|
Plate in Workzone |
Phenolic resin Laminate |
|
Electrical Outlets |
AC 220V 2ea |
|
Utility |
Water Cock / Air Cock / Gas Cock (option) |
|
Controller |
L.C.D Display |
|
Supply Voltage & Frequency |
AC220V. 50/60Hz |
|
GENERAL SPECIFICATIONS |
SNFH - 1000 |
SNFH - 2011 |
SNFH - 2012 |
SNFH - 2013 |
|---|---|---|---|---|
External Dimension |
1000x790x2300(mm) |
1200x790x2300(mm) |
1500x790x2300(mm) |
1800x790x2300(mm) |
Internal Workzone Dimension (L x D x W) |
810x535x1140 |
1010x535x1140 |
1310x535x1140 |
1610x535x1140 |
Duct |
150∅ |
200∅ |
200∅ |
200∅ or 250∅ |
Power Consumption |
175W |
280W |
280W |
280W or 470W |
Product Name
Model |
SNFH - 1000 |
SNFH - 2011 |
SNFH - 2012 |
|---|---|---|---|
G2B Identification number |
23067289 |
23067290 |
23067291 |
S2B Item number |
201902148398737 |
201902148398779 |
201902148398849 |
Features
Excellent fire resistance and durability due to the use of phenolic laminate for the interior material .
Real-time monitoring of wind speed status and alarm sound when wind speed falls below the set value via the application of a wind speed controller
Safely dispose of waste reagents after experiments by installing a waste reagent treatment facility
Useful for storing acidic solvents, flammable organic compounds, etc. by installing a safety cabinet in the submerged space .
Applying a sliding mechanism to the bottom of the upper and lower sliding doors facilitates testing and minimizes the impact on face airflow velocity.
Controller for face wind speed control
Lamp and blower on/off function
Checking and monitoring wind speed conditions
Automatic face wind speed control equipped with a VAV sensor module
Warning sound when wind speed falls below the set value
door
Sliding mechanism adopted at the bottom of the RAM top-and-bottom sliding door
Waste reagent treatment device
Installed facilities to handle waste reagents more safely
Detailed specification sheets are shown in the product images.