Flow & Pressure Switch FS Series
Flow & Pressure Switch
FS series
Features
The paddle type FS series are designed to provide excellent performance where accuracy, reliability, and rugged construction are required in liquid flow linescarrying water or any fluid neither harmful to brass and proshor bronze nor classified as a hazardous fluids.
They can be wired to close one circuit and open a seconde circuit when liquid flow either exceeds or drops below the adjusted flow rate.
Precautions
The FS series are recommended for liquid pressure and temperature as mentioned below and must not be used on lines carrying liquids below 0℃.
These series may be used on liquids with high salt or chlorince content but is not for use in hazardous atmospheres.
They may be also used outdoors but must be protected from weather or splashing water.
FS flow switches are designed for use only as operating controls.
As an operating control failure would result in personal injury or loss of property, it is the responsibility of user to add safety devices that protect against, or supervisory systems that warn of control failure.
Specifications
Working pressure |
10kgf/㎠ |
|---|---|
Proof pressure |
17.5kgf/㎠ |
Insulation resistance |
≥100Ω, DC500VM |
Withstand voltage |
AC1500V/MIN |
Contact service life |
1000K Cycle |
Bellows service life |
500K Cycle |
Fluid temperature |
Max. 100℃ |
Type |
Voltage |
Load resistance |
Lamp load |
Motor load |
|---|---|---|---|---|
AC (Standard) |
AC 125V |
5A |
44A |
5A |
AC 250V |
2.5A |
22A |
2.5A |
|
DC |
DC 115V |
0.3A |
- |
- |
DC 230V |
0.15A |
- |
- |
Structure
Dimensions
Installation
HS Series
Features
Air, water, and inert medium
Mounting bracket is included.
Micro-switches ensures a reliable conversion
Specifications
Model |
Pressure range (kgf/㎠) |
Differential pressure (kgf/㎠) |
Factory setting |
Max. proof pressure (kgf/㎠) |
Fluid |
Ambient & fluid temperature |
Weight (kg) |
||||
|---|---|---|---|---|---|---|---|---|---|---|---|
Min. |
Max. |
Min. |
Max. |
Min. |
Max. |
||||||
HS-203 |
-50cmHg |
3 |
0.35 |
2 |
0.5 |
1.5 |
11 |
Non-corrosive fluid, Air, Fluid, Inert gas, Steam |
-10℃~120℃ |
0.42 |
|
HS-206 |
-50cmHg |
6 |
0.6 |
4 |
2 |
3 |
16.5 |
||||
HS-210 |
1 |
10 |
1 |
3 |
4 |
6 |
16.5 |
||||
HS-220 |
5 |
20 |
3 |
5 |
12 |
15 |
40 |
||||
HS-230 |
5 |
30 |
3 |
10 |
20 |
25 |
40 |
||||
HS-306 |
LOW SIDE |
-50cmHg |
6 |
0.6 |
4 |
3 |
2 |
16.5 |
0.61 |
||
HIGH SIDE |
8 |
30 |
Approx. 4 setting value |
16 |
20 |
40 |
|||||
HS-306M |
LOW SIDE |
-50cmHg |
6 |
0.6 |
4 |
2 |
2 |
16.5 |
|||
HIGH SIDE |
8 |
30 |
Manual reset |
Manual reset |
20 |
40 |
|||||
HS-606 |
LOW SIDE |
-50cmHg |
6 |
0.6 |
4 |
3 |
2 |
16.5 |
|||
HIGH SIDE |
8 |
30 |
Approx. 4 setting value |
16 |
20 |
40 |
|||||
HS-606M |
LOW SIDE |
-50cmHg |
6 |
0.6 |
4 |
3 |
2 |
16.5 |
|||
HIGH SIDE |
8 |
30 |
Manual reset |
Manual reset |
20 |
40 |
|||||
Rated Voltage
|
Rated voltage /Rated current(A) |
Power factor |
125/250V |
|
|---|---|---|---|
Non-inductive current |
1 |
12 |
|
|
Inductive current |
Total load |
0.75 |
12 |
Locked Rotor |
0.45 |
72 |
|
Dimensions-Single
Model |
A |
B |
C |
|---|---|---|---|
HS-203 |
38.5 |
38.9 |
22.4 |
HS-206 |
34.4 |
36 |
22.4 |
HS-210 | |||
HS-220 |
22 |
32.7 |
18.5 |
HS-230 |
Dimensions - Dual
KTD-600 Series
Features
Indicate positive and negative pressure
Compact design and light weight
One touch zero adjustment function
Return function in automatic operating mode
Independent 2-channel output according to user setting
Use high precision semiconductor pressure sensor. Widely used, when precise pressure control is required, such as semiconductor manufacturing line, medical equipment, automation line and etc.
Function
Change display unit
There are different type of pressure unit. Please select the proper unit depending on application. When changing the display unit, preset value will be calculated according to the display unit.
Zero point adjustment
This function is to set the display value of pressure at zero when port is opened to atmospheric pressure. Press ZERO key for more than 2sec in RUN mode set value forcibly. When the zero point adjustment is completed, it will return to RUN mode automatically.
Change response time
It is able to set 100 kinds of response time (5~495ms) and if the response time is getting longer, the sensing value will be more stable.
Change output mode
There are 4 kinds of control output modes. (Please refer output operation mode).
Output response to cable OUT 1 and OUT 2 according to output mode.
-Control output 1 : Black cable (OUT1)
-Control output 2 : White cable (OUT2)
Analog output status display
The output of the pressure sensor is indicated by flashing of 2 LEDs.
- OUT 1 is ON, LED 1 will be ON
- OUT 2 is ON, LED 2 will be ON
Real time display
- When advance to Parameter setting mode, if the setting value is changed, the output will change according to the changed value.
Automatic RUN mode reset
When changing unit, set unit by using UNIT key and it will return to RUN mode automatically after 1sec. When advance to Parameter setting mode, if any key is untouched for over 10 sec, it will return to RUN mode automatically.
Analog output
- Analog output cable : Grey cable
- Analog output status : Please refer to analog output mode of each model.
Specifications
Model |
KTD-600V |
KTD-600 |
|---|---|---|
Pressure type |
Compound pressure (Pneumatic) |
Negative pressure (Vacuum) |
Display pressure range |
-0.95~ 9kgf/㎠ |
-0.99~0kgf/㎠ |
Rated pressure range |
-0.95~ 9kgf/㎠ |
-0.97~ 0kgf/㎠ |
Proof pressure |
2 times of rated pressure |
1.5 times of rated pressure |
Fluid |
Air, Non-corrosive gas |
|
Power supply |
12~24VDC ± 10% (Ripple P-P) |
|
Current consumption |
Below 30mA |
|
Ambient temperature |
0℃~50℃ (at non-freezing status |
|
Strorage temperature |
-40℃~125℃ (at non-freezing status) |
|
Humidity |
30~80%RH (at non-freezing status) |
|
|
Output temperature characteristic |
-0.1 ~- 0.2% Span/℃ |
-0.2 ~- 0.3% Span/℃ |
Linearity |
±0.3% Span |
|
Response time |
1~99 Step (1Step = 5msec) |
|
Control output |
NPN Open collector 2 individual output (Max. load current ≤100mA) |
|
Analog output |
Analog Mode |
Analog Mode |
Resolution : 1~5V (≥1/800) 0~5V (≥1/1000) | ||
Display method |
- 1LED (± display), 3 digit 7 segment - (OUT1, OUT2) 2 output displayed by 2 LED |
|
Material |
Case & Panel holder set : PC |
|
Pressure port |
M5 (Built-in) |
|
Wire |
Ø4.2 / 24AWG X 5Core / 약 1.5m (±5%) |
|
Accessory |
Manual, Mounting bracket, Panel holder set |
|
Display pressure unit |
kPa, mbar, psi |
kPa, bar, psi |
Weight |
156g |
|
Dimensions
Dimension-Panel Attachment
Installation
MFPS02 Series
Features
Simultaneous monitoring of flow rate and pressure
Approximate linear analog output of flow rate
3-color indicator
2 analog outputs 1~5V
Response time ≤5ms
Application
Specification
Models |
003 |
005 |
010 |
050 |
100 |
R003 |
R005 |
R010 |
R050 |
R100 |
|
|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate |
Measured Flow Rate Range |
0~0.3 |
0~0.5 |
0~1 |
0~5 |
0~10 |
-0.3~0.3 |
-0.5~0.5 |
-1~1 |
-5~5 |
-10~10 |
Flow Direction |
Uni-directional |
Bi-directional |
|||||||||
Input |
Rated Pressure Range |
-100~100kPa |
|||||||||
Proof Pressure |
300kPa |
||||||||||
Fluid |
Dry air, N₂, non-corrosive/non-flammable gas |
||||||||||
Power Supply Voltage |
15~24V DC ±10%, Ripple(P-P)≤10% |
||||||||||
Current Consumption |
≤30mA |
||||||||||
Flow Rate |
Repeatability |
≤±2% F.S. |
|||||||||
Linearity |
Non-linearity Note 1) |
||||||||||
|
Temp. Characteristics Note 2) |
≤±0.6% F.S./℃ |
≤±0.3% F.S./℃ |
|||||||||
|
Pressure Characteristics Note 3) |
±10% F.S. |
±5% F.S. |
|||||||||
Pressure |
Repeatability |
±1% F.S. |
|||||||||
Linearity |
±0.5% F.S |
||||||||||
|
Temp. Characteristics Note 2) |
±2% F.S. |
||||||||||
Response Time |
Flow Rate |
≤5ms (90% response time) |
|||||||||
Pressure |
≤1ms |
||||||||||
Indicator Light |
Green LED, Orange LED, Red LED |
||||||||||
|
Analog Output |
Flow Rate |
Voltage output: 1~5V ±5% F.S. (±0.2V)(Non-linear) |
|||||||||
Output impedance: 1kΩ | |||||||||||
Pressure |
Voltage output: 1~5V ±1% F.S. (±0.04V)(Linear) |
||||||||||
Output impedance: 1kΩ | |||||||||||
|
Environ -ment |
Enclosure (Protection) |
IP40 |
|||||||||
Operating Fluid Temp. |
0~50℃(No condensation or freezing) |
||||||||||
Ambient Temp. Range |
Operating: 0~50℃, Storage: -10~60℃ (No condensation or freezing) |
||||||||||
Ambient Humidity Range |
Operating/Storage: 35~85%RH (No condensation) |
||||||||||
Dielectric Strength |
1000V AC for 1 minute (between case and lead wire) |
||||||||||
Insulation Resistance |
≥50MΩ (500V DC, between case and lead wire) |
||||||||||
Vibration |
Total amplitude 1.5mm or 10G, 1-min scan 10~55Hz~10Hz, X,Y,Z each direction 2 hours |
||||||||||
Shock |
100m/s² (10G) X,Y,Z each direction 3 times |
||||||||||
Lead Wire |
Ø2.9 PUR - 28AWG(0.078㎟) - 4-core |
||||||||||
Weight |
Approx. 8.6g (w/o port), Approx. 12.2g (M5 port) / Lead wire(3M): 34.5g |
||||||||||
Notes
Note 1) Non-linearity linear analog output (±10% F.S.), 0~10L, -10~10L models excluded.
Note 2) Benchmark: 25℃ (Temp range: 0~50℃)
Note 3) Benchmark: 150kPa (Pressure range: -100~200kPa)
Outline Dimensions
Detailed specification sheets are shown in the product images.
Flow & Pressure Switch FS Series
Flow & Pressure Switch FS Series: overview and buying guide
The Flow & Pressure Switch FS Series (model FS Series) is made by KCC and listed in our fa (factory automation) range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.
Frequently asked questions
How much does the Flow & Pressure Switch FS Series cost?
Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.
Can you ship the Flow & Pressure Switch FS Series to my country?
Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.
Is this a genuine KCC product?
We purchase directly from KCC or its authorised channels and confirm the model and specifications with the manufacturer before ordering.
What is the minimum order quantity?
For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.
Flow & Pressure Switch
FS series
Features
The paddle type FS series are designed to provide excellent performance where accuracy, reliability, and rugged construction are required in liquid flow linescarrying water or any fluid neither harmful to brass and proshor bronze nor classified as a hazardous fluids.
They can be wired to close one circuit and open a seconde circuit when liquid flow either exceeds or drops below the adjusted flow rate.
Precautions
The FS series are recommended for liquid pressure and temperature as mentioned below and must not be used on lines carrying liquids below 0℃.
These series may be used on liquids with high salt or chlorince content but is not for use in hazardous atmospheres.
They may be also used outdoors but must be protected from weather or splashing water.
FS flow switches are designed for use only as operating controls.
As an operating control failure would result in personal injury or loss of property, it is the responsibility of user to add safety devices that protect against, or supervisory systems that warn of control failure.
Specifications
Working pressure |
10kgf/㎠ |
|---|---|
Proof pressure |
17.5kgf/㎠ |
Insulation resistance |
≥100Ω, DC500VM |
Withstand voltage |
AC1500V/MIN |
Contact service life |
1000K Cycle |
Bellows service life |
500K Cycle |
Fluid temperature |
Max. 100℃ |
Type |
Voltage |
Load resistance |
Lamp load |
Motor load |
|---|---|---|---|---|
AC (Standard) |
AC 125V |
5A |
44A |
5A |
AC 250V |
2.5A |
22A |
2.5A |
|
DC |
DC 115V |
0.3A |
- |
- |
DC 230V |
0.15A |
- |
- |
Structure
Dimensions
Installation
HS Series
Features
Air, water, and inert medium
Mounting bracket is included.
Micro-switches ensures a reliable conversion
Specifications
Model |
Pressure range (kgf/㎠) |
Differential pressure (kgf/㎠) |
Factory setting |
Max. proof pressure (kgf/㎠) |
Fluid |
Ambient & fluid temperature |
Weight (kg) |
||||
|---|---|---|---|---|---|---|---|---|---|---|---|
Min. |
Max. |
Min. |
Max. |
Min. |
Max. |
||||||
HS-203 |
-50cmHg |
3 |
0.35 |
2 |
0.5 |
1.5 |
11 |
Non-corrosive fluid, Air, Fluid, Inert gas, Steam |
-10℃~120℃ |
0.42 |
|
HS-206 |
-50cmHg |
6 |
0.6 |
4 |
2 |
3 |
16.5 |
||||
HS-210 |
1 |
10 |
1 |
3 |
4 |
6 |
16.5 |
||||
HS-220 |
5 |
20 |
3 |
5 |
12 |
15 |
40 |
||||
HS-230 |
5 |
30 |
3 |
10 |
20 |
25 |
40 |
||||
HS-306 |
LOW SIDE |
-50cmHg |
6 |
0.6 |
4 |
3 |
2 |
16.5 |
0.61 |
||
HIGH SIDE |
8 |
30 |
Approx. 4 setting value |
16 |
20 |
40 |
|||||
HS-306M |
LOW SIDE |
-50cmHg |
6 |
0.6 |
4 |
2 |
2 |
16.5 |
|||
HIGH SIDE |
8 |
30 |
Manual reset |
Manual reset |
20 |
40 |
|||||
HS-606 |
LOW SIDE |
-50cmHg |
6 |
0.6 |
4 |
3 |
2 |
16.5 |
|||
HIGH SIDE |
8 |
30 |
Approx. 4 setting value |
16 |
20 |
40 |
|||||
HS-606M |
LOW SIDE |
-50cmHg |
6 |
0.6 |
4 |
3 |
2 |
16.5 |
|||
HIGH SIDE |
8 |
30 |
Manual reset |
Manual reset |
20 |
40 |
|||||
Rated Voltage
|
Rated voltage /Rated current(A) |
Power factor |
125/250V |
|
|---|---|---|---|
Non-inductive current |
1 |
12 |
|
|
Inductive current |
Total load |
0.75 |
12 |
Locked Rotor |
0.45 |
72 |
|
Dimensions-Single
Model |
A |
B |
C |
|---|---|---|---|
HS-203 |
38.5 |
38.9 |
22.4 |
HS-206 |
34.4 |
36 |
22.4 |
HS-210 | |||
HS-220 |
22 |
32.7 |
18.5 |
HS-230 |
Dimensions - Dual
KTD-600 Series
Features
Indicate positive and negative pressure
Compact design and light weight
One touch zero adjustment function
Return function in automatic operating mode
Independent 2-channel output according to user setting
Use high precision semiconductor pressure sensor. Widely used, when precise pressure control is required, such as semiconductor manufacturing line, medical equipment, automation line and etc.
Function
Change display unit
There are different type of pressure unit. Please select the proper unit depending on application. When changing the display unit, preset value will be calculated according to the display unit.
Zero point adjustment
This function is to set the display value of pressure at zero when port is opened to atmospheric pressure. Press ZERO key for more than 2sec in RUN mode set value forcibly. When the zero point adjustment is completed, it will return to RUN mode automatically.
Change response time
It is able to set 100 kinds of response time (5~495ms) and if the response time is getting longer, the sensing value will be more stable.
Change output mode
There are 4 kinds of control output modes. (Please refer output operation mode).
Output response to cable OUT 1 and OUT 2 according to output mode.
-Control output 1 : Black cable (OUT1)
-Control output 2 : White cable (OUT2)
Analog output status display
The output of the pressure sensor is indicated by flashing of 2 LEDs.
- OUT 1 is ON, LED 1 will be ON
- OUT 2 is ON, LED 2 will be ON
Real time display
- When advance to Parameter setting mode, if the setting value is changed, the output will change according to the changed value.
Automatic RUN mode reset
When changing unit, set unit by using UNIT key and it will return to RUN mode automatically after 1sec. When advance to Parameter setting mode, if any key is untouched for over 10 sec, it will return to RUN mode automatically.
Analog output
- Analog output cable : Grey cable
- Analog output status : Please refer to analog output mode of each model.
Specifications
Model |
KTD-600V |
KTD-600 |
|---|---|---|
Pressure type |
Compound pressure (Pneumatic) |
Negative pressure (Vacuum) |
Display pressure range |
-0.95~ 9kgf/㎠ |
-0.99~0kgf/㎠ |
Rated pressure range |
-0.95~ 9kgf/㎠ |
-0.97~ 0kgf/㎠ |
Proof pressure |
2 times of rated pressure |
1.5 times of rated pressure |
Fluid |
Air, Non-corrosive gas |
|
Power supply |
12~24VDC ± 10% (Ripple P-P) |
|
Current consumption |
Below 30mA |
|
Ambient temperature |
0℃~50℃ (at non-freezing status |
|
Strorage temperature |
-40℃~125℃ (at non-freezing status) |
|
Humidity |
30~80%RH (at non-freezing status) |
|
|
Output temperature characteristic |
-0.1 ~- 0.2% Span/℃ |
-0.2 ~- 0.3% Span/℃ |
Linearity |
±0.3% Span |
|
Response time |
1~99 Step (1Step = 5msec) |
|
Control output |
NPN Open collector 2 individual output (Max. load current ≤100mA) |
|
Analog output |
Analog Mode |
Analog Mode |
Resolution : 1~5V (≥1/800) 0~5V (≥1/1000) | ||
Display method |
- 1LED (± display), 3 digit 7 segment - (OUT1, OUT2) 2 output displayed by 2 LED |
|
Material |
Case & Panel holder set : PC |
|
Pressure port |
M5 (Built-in) |
|
Wire |
Ø4.2 / 24AWG X 5Core / 약 1.5m (±5%) |
|
Accessory |
Manual, Mounting bracket, Panel holder set |
|
Display pressure unit |
kPa, mbar, psi |
kPa, bar, psi |
Weight |
156g |
|
Dimensions
Dimension-Panel Attachment
Installation
MFPS02 Series
Features
Simultaneous monitoring of flow rate and pressure
Approximate linear analog output of flow rate
3-color indicator
2 analog outputs 1~5V
Response time ≤5ms
Application
Specification
Models |
003 |
005 |
010 |
050 |
100 |
R003 |
R005 |
R010 |
R050 |
R100 |
|
|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate |
Measured Flow Rate Range |
0~0.3 |
0~0.5 |
0~1 |
0~5 |
0~10 |
-0.3~0.3 |
-0.5~0.5 |
-1~1 |
-5~5 |
-10~10 |
Flow Direction |
Uni-directional |
Bi-directional |
|||||||||
Input |
Rated Pressure Range |
-100~100kPa |
|||||||||
Proof Pressure |
300kPa |
||||||||||
Fluid |
Dry air, N₂, non-corrosive/non-flammable gas |
||||||||||
Power Supply Voltage |
15~24V DC ±10%, Ripple(P-P)≤10% |
||||||||||
Current Consumption |
≤30mA |
||||||||||
Flow Rate |
Repeatability |
≤±2% F.S. |
|||||||||
Linearity |
Non-linearity Note 1) |
||||||||||
|
Temp. Characteristics Note 2) |
≤±0.6% F.S./℃ |
≤±0.3% F.S./℃ |
|||||||||
|
Pressure Characteristics Note 3) |
±10% F.S. |
±5% F.S. |
|||||||||
Pressure |
Repeatability |
±1% F.S. |
|||||||||
Linearity |
±0.5% F.S |
||||||||||
|
Temp. Characteristics Note 2) |
±2% F.S. |
||||||||||
Response Time |
Flow Rate |
≤5ms (90% response time) |
|||||||||
Pressure |
≤1ms |
||||||||||
Indicator Light |
Green LED, Orange LED, Red LED |
||||||||||
|
Analog Output |
Flow Rate |
Voltage output: 1~5V ±5% F.S. (±0.2V)(Non-linear) |
|||||||||
Output impedance: 1kΩ | |||||||||||
Pressure |
Voltage output: 1~5V ±1% F.S. (±0.04V)(Linear) |
||||||||||
Output impedance: 1kΩ | |||||||||||
|
Environ -ment |
Enclosure (Protection) |
IP40 |
|||||||||
Operating Fluid Temp. |
0~50℃(No condensation or freezing) |
||||||||||
Ambient Temp. Range |
Operating: 0~50℃, Storage: -10~60℃ (No condensation or freezing) |
||||||||||
Ambient Humidity Range |
Operating/Storage: 35~85%RH (No condensation) |
||||||||||
Dielectric Strength |
1000V AC for 1 minute (between case and lead wire) |
||||||||||
Insulation Resistance |
≥50MΩ (500V DC, between case and lead wire) |
||||||||||
Vibration |
Total amplitude 1.5mm or 10G, 1-min scan 10~55Hz~10Hz, X,Y,Z each direction 2 hours |
||||||||||
Shock |
100m/s² (10G) X,Y,Z each direction 3 times |
||||||||||
Lead Wire |
Ø2.9 PUR - 28AWG(0.078㎟) - 4-core |
||||||||||
Weight |
Approx. 8.6g (w/o port), Approx. 12.2g (M5 port) / Lead wire(3M): 34.5g |
||||||||||
Notes
Note 1) Non-linearity linear analog output (±10% F.S.), 0~10L, -10~10L models excluded.
Note 2) Benchmark: 25℃ (Temp range: 0~50℃)
Note 3) Benchmark: 150kPa (Pressure range: -100~200kPa)
Outline Dimensions
Detailed specification sheets are shown in the product images.