Flow Indicator ATI-100
Flow Indicator
Features
The ATI Series flow monitor is an indicator that receives pulse (frequency) signals from a sensor and displays both instantaneous and cumulative flow rates. Flow rates are displayed in English letters and numbers on a 2-line, 16-character LCD screen designed for easy readability.
Specifications
Indicator |
2Line 16Character LCD, Back Light |
|---|---|
Display Refresh Rate |
0.25, 0.5, 1.0, 2sec |
Output Voltage |
12V, 50mA |
Operating Temperature |
-10 to 70℃ |
Input Range |
0 to 5000Hz |
Input Signal |
Open Colector, Voltage pulse, Reed Switch |
Ratio Range |
0.001~99.999.999 (Pluse/Unit) |
Output Signal |
4-20mADC, 16-bit |
Relay Output |
5A, 250VAC/30VDC or 10A, 125VAC |
Pulse Output |
10 to500ms (variable), MOSFET Photovotaic Relay |
140mA Max | |
Communication Output |
RS232 or RS485 |
Operating Power |
100~240VAC, 10W (AC INPUT) |
18~36VDC, 6W (DC INPUT) |
Power Connection
The operating power supply for the ATI can be configured as either AC or DC power depending on customer requirements, and this selection is made at the time of shipment.
The AC power supply accepts a wide input voltage range of 85–264 VAC, regardless of internal settings.
The DC power supply accepts an input voltage of 18–36 VDC, regardless of polarity.
Input Signal (Sensor) Wiring
The ATI input signal (sensor) wiring is configured to accept open-collector signals as shipped.
You can configure a separate input by using an external pull-up resistor.
Terminal 11 outputs 12 VDC to the external circuit. This can be used if the sensor requires a separate power supply.
Open Collector: Used when the pulses output by the sensor do not apply a voltage.
Reed Switch: Used when the pulse output from the sensor does not apply a voltage; it is used with reed switches and relay contacts (dry contacts).
Square Wave: Used when the pulse output from the sensor applies a voltage.
Pulse Output Wiring
The ATI's pulse output is a MOSFET photovoltaic relay output that operates regardless of polarity. The pulse width can be set by the user within a range of 10 to 500 ms via the program; if pulse widths overlap, the system automatically sets and outputs the optimal pulse width.
4-20 mA DC Output Wiring
The ATI can transmit a 4-20 mA DC output corresponding to the measured value. The output range can be configured via the program menu, and with its high-precision 16-bit resolution, it is suitable for data logging and transmission to PLCs and DAQ boards.
Alarm Relay Wiring
The ATI supports two alarm contacts, which can be configured via the program.
* The default setting is NO (Normally Open), but the internal configuration can be set to either NO or NC.
Dimensions
Detailed specification sheets are shown in the product images.
Flow Indicator ATI-100
Flow Indicator ATI-100: overview and buying guide
The Flow Indicator ATI-100 (model ATI-100) is made by AUTOFLOW and listed in our chemical range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.
Frequently asked questions
How much does the Flow Indicator ATI-100 cost?
Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.
Can you ship the Flow Indicator ATI-100 to my country?
Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.
Is this a genuine AUTOFLOW product?
We purchase directly from AUTOFLOW or its authorised channels and confirm the model and specifications with the manufacturer before ordering.
What is the minimum order quantity?
For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.
Flow Indicator
Features
The ATI Series flow monitor is an indicator that receives pulse (frequency) signals from a sensor and displays both instantaneous and cumulative flow rates. Flow rates are displayed in English letters and numbers on a 2-line, 16-character LCD screen designed for easy readability.
Specifications
Indicator |
2Line 16Character LCD, Back Light |
|---|---|
Display Refresh Rate |
0.25, 0.5, 1.0, 2sec |
Output Voltage |
12V, 50mA |
Operating Temperature |
-10 to 70℃ |
Input Range |
0 to 5000Hz |
Input Signal |
Open Colector, Voltage pulse, Reed Switch |
Ratio Range |
0.001~99.999.999 (Pluse/Unit) |
Output Signal |
4-20mADC, 16-bit |
Relay Output |
5A, 250VAC/30VDC or 10A, 125VAC |
Pulse Output |
10 to500ms (variable), MOSFET Photovotaic Relay |
140mA Max | |
Communication Output |
RS232 or RS485 |
Operating Power |
100~240VAC, 10W (AC INPUT) |
18~36VDC, 6W (DC INPUT) |
Power Connection
The operating power supply for the ATI can be configured as either AC or DC power depending on customer requirements, and this selection is made at the time of shipment.
The AC power supply accepts a wide input voltage range of 85–264 VAC, regardless of internal settings.
The DC power supply accepts an input voltage of 18–36 VDC, regardless of polarity.
Input Signal (Sensor) Wiring
The ATI input signal (sensor) wiring is configured to accept open-collector signals as shipped.
You can configure a separate input by using an external pull-up resistor.
Terminal 11 outputs 12 VDC to the external circuit. This can be used if the sensor requires a separate power supply.
Open Collector: Used when the pulses output by the sensor do not apply a voltage.
Reed Switch: Used when the pulse output from the sensor does not apply a voltage; it is used with reed switches and relay contacts (dry contacts).
Square Wave: Used when the pulse output from the sensor applies a voltage.
Pulse Output Wiring
The ATI's pulse output is a MOSFET photovoltaic relay output that operates regardless of polarity. The pulse width can be set by the user within a range of 10 to 500 ms via the program; if pulse widths overlap, the system automatically sets and outputs the optimal pulse width.
4-20 mA DC Output Wiring
The ATI can transmit a 4-20 mA DC output corresponding to the measured value. The output range can be configured via the program menu, and with its high-precision 16-bit resolution, it is suitable for data logging and transmission to PLCs and DAQ boards.
Alarm Relay Wiring
The ATI supports two alarm contacts, which can be configured via the program.
* The default setting is NO (Normally Open), but the internal configuration can be set to either NO or NC.
Dimensions
Detailed specification sheets are shown in the product images.