{"product_id":"feature-54512","title":"Feature","description":"\u003ch3\u003eSpecial Character by Part\u003c\/h3\u003e\u003cp\u003e■ Fans \u003cbr\u003e \u003cbr\u003eFans shall be vane-axial induced type of cast aluminum ally blades. \u003cbr\u003eLow cost and high efficient running \u003cbr\u003e \u003c\/p\u003e\u003cp\u003e■ Water distribution nozzile \u003cbr\u003e \u003cbr\u003eThe sater shall be distributed over the entire coil surface by precision molded ABS spray nozzle. \u003cbr\u003e \u003c\/p\u003e\u003cp\u003e\u003cbr\u003e \u003cbr\u003e■ Pan \u0026amp; casing \u003cbr\u003e \u003cbr\u003ePan and casing shall be constructed of hot-dip galvanized steel gor long life and durability. \u003cbr\u003e \u003c\/p\u003e\u003cp\u003e■ Recirculation pump \u003cbr\u003e \u003cbr\u003ePump shall be a close-coupled centrifugal type.IP54 motor for dirp-proof. \u003cbr\u003e \u003c\/p\u003e\u003cp\u003e■ Louver \u003cbr\u003e \u003cbr\u003eAir entrainment efficient is a good and the spray branches is minimum like as honeycomb. \u003c\/p\u003e\u003cp\u003e\u003cbr\u003e■ Eliminators \u003c\/p\u003e\u003cp\u003eHighly Efficient Removal of Arsenic Acid\u003cbr\u003eOur drift eliminator efficiently removes up to 0.002% arsenic acid contamination of the circulating water flow by rapidly transforming the direction of air flow three times using air pressure. \u003cbr\u003eThe user can extend the space of the drift eliminator supporter, making air flow resistance low. \u003cbr\u003eNotice: Saturated air meeting cold air produce the moisture you may see on the drift eliminator. Such moisture is normal and does not affect the device’s performance. \u003cbr\u003e \u003c\/p\u003e\u003cp\u003e■ Strainer \u003c\/p\u003e\u003cp\u003eStrainer shall be constructed of stainless steel NO304 for prevent the erodion and be apt to checking,dismantle,assembling and cleaning. \u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\u003ch3\u003eComparison\u003c\/h3\u003e\u003cp\u003e■ \u003cstrong\u003eCOMPARISON OF EVAPORATIVE CONDENSER\u003c\/strong\u003e\u003c\/p\u003e\u003ctable class=\"pem-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCOPPER TUBE EVA-CON\u003c\/td\u003e\n\u003ctd\u003eALUMINUM PIPE EVA-CON\u003c\/td\u003e\n\u003ctd\u003eSTEEL-PIPE EVA-CON\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial(Main element)\u003c\/td\u003e\n\u003ctd\u003eCU\u003c\/td\u003e\n\u003ctd\u003eAL\u003c\/td\u003e\n\u003ctd\u003eFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecific weight (kg\/m2)\u003c\/td\u003e\n\u003ctd\u003eC1220\u003c\/td\u003e\n\u003ctd\u003eA1070\u003c\/td\u003e\n\u003ctd\u003eSTPG410\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal conductivity(kcl\/mh℃)\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003ctd\u003e170\u003c\/td\u003e\n\u003ctd\u003e39\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTube Size\u003c\/td\u003e\n\u003ctd\u003eTube Size\u003c\/td\u003e\n\u003ctd\u003e￠22\u003c\/td\u003e\n\u003ctd\u003e￠25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsed Refrigent\u003c\/td\u003e\n\u003ctd\u003eFREON\u003c\/td\u003e\n\u003ctd\u003eNH₃\u003c\/td\u003e\n\u003ctd\u003eFREON, NH₃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommenting Part of In,Outlet\u003c\/td\u003e\n\u003ctd\u003eSTEEL PIPE\u003c\/td\u003e\n\u003ctd\u003eINSULATION FLANGE \u003c\/td\u003e\n\u003ctd\u003eSTEEL PIPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeature\u003c\/td\u003e\n\u003ctd\u003eㆍGood in heat conductivity\u003cbr\u003e ㆍLighter efficiency of\u003cbr\u003e Evaporativeaction pertransfer\u003cbr\u003e Area due to R-22 only\u003cbr\u003e ㆍTo make corrosion at the NH₃\u003c\/td\u003e\n\u003ctd\u003eㆍGood In heat conductivity\u003cbr\u003e ㆍLower operation\u003cbr\u003e ㆍShort useful lengthper R\/T\u003cbr\u003e ㆍEasy installation with\u003cbr\u003e lighter in weight\u003c\/td\u003e\n\u003ctd\u003eㆍPerfect in corrosion \u0026amp;\u003cbr\u003e heat resistant\u003cbr\u003e ㆍHot dipped plating\u003cbr\u003e ㆍHeavy in weight\u003cbr\u003e ㆍLong useful lengthper 1R\/T\u003cbr\u003e ㆍApply to and NH₃ Freon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"pem-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComparison Criteria \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e■ Comparison Criteria \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e■ Forced Draft Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe axial fan\u003c\/td\u003e\n\u003ctd\u003eon the upper ventilator tube is positioned.\u003c\/td\u003e\n\u003ctd\u003eon the side of an exposed tube.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEven air flow\u003c\/td\u003e\n\u003ctd\u003eleaning to one side.\u003c\/td\u003e\n\u003ctd\u003eleads to the circulation of internal wind velocity.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLevel of Noise\u003c\/td\u003e\n\u003ctd\u003erelatively low\u003c\/td\u003e\n\u003ctd\u003erelatively high\u003cbr\u003e The use of a Centrifugal Fan helps reduce noise.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepair, Maintenance\u003c\/td\u003e\n\u003ctd\u003eIt is difficult for a Fan Motor to be checked, repaired and replaced.\u003c\/td\u003e\n\u003ctd\u003eIt is easy for a Fan Motor to be checked, repaired and replaced.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Cost\u003c\/td\u003e\n\u003ctd\u003eIt is difficult for a Fan Motor to bechecked, repaired and replaced.\u003c\/td\u003e\n\u003ctd\u003eDue to significant air resistance, a characteristic of the forceddraft type, fan power expense increases by 40% or more.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInvestment Cost\u003c\/td\u003e\n\u003ctd\u003e1.0\u003c\/td\u003e\n\u003ctd\u003e1.6 ~ 1.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsages\u003c\/td\u003e\n\u003ctd\u003eFor a general outdoor type\u003c\/td\u003e\n\u003ctd\u003ebasement installation-purpose is appropriate for its large aerodynamic resistance.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Recirculation Issues\u003c\/td\u003e\n\u003ctd\u003eThe speed of air drain is faster than that of air suctionwith little occurrence of air recirculation.\u003c\/td\u003e\n\u003ctd\u003eAir suction is fast while air drain is slow,affecting air recirculation efficiency.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eEvaporative Condenser\u003c\/h3\u003e\u003cp\u003e■ \u003cstrong\u003eEVAPORATIVE CONDENSER Selection Method\u003c\/strong\u003e \u003c\/p\u003e\u003ctable class=\"pem-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eon the ton of evaporation (Condensing Capacity)\u003c\/td\u003e\n\u003ctd\u003eMethod according to the calorific value based\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelection Method\u003c\/td\u003e\n\u003ctd\u003e1. Determine the number of evaporation tons,condensing temperature, suction temperature, wet-bulb temperature.\u003cbr\u003e 2. Select an evaporative condenser according to evaporatingload and refrigerant type, each capacity factor by condensingtemperature and suction temperature.\u003cbr\u003e 3. Mainly applicable to standard open-type compressor.EVAPORATIVE CONDENSER Load\u003cbr\u003e 250 Ton X condensing temperature x capacity factor xcapacity factor of suction temperature\u003c\/td\u003e\n\u003ctd\u003e1. Determine according to evaporation load, compressor’sshaft power, condensing temperature and wet-bulb temperature.\u003cbr\u003e 2. Determine according to evaporation load, compressor’sshaft power, condensing temperature and wet-bulb temperature.\u003cbr\u003e 3. Mainly applies to a sealed compressor, screw compressor and centrifugal compressor.\u003cbr\u003e EVAPORATIVE CONDENSER CAPACITY\u003cbr\u003e (evaporation load + shaft power ) x dissipation factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelection Criteria\u003c\/td\u003e\n\u003ctd\u003eㆍRefrigerant: Freon (R-22)\u003cbr\u003e ㆍEvaporation ton load = 250Ton\u003cbr\u003e ㆍCondensing temperature = 40℃\u003cbr\u003e ㆍSuction temperature = -10\u003cbr\u003e ㆍWet-bulb temperature = 27℃\u003c\/td\u003e\n\u003ctd\u003eㆍRefrigerant: Ammonia (NH₃)\u003cbr\u003e ㆍEvaporator load + compressor shaft power 280Ton\u003cbr\u003e ㆍCondensing temperature = 35℃\u003cbr\u003e ㆍWet-bulb temperature = 27℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelection\u003c\/td\u003e\n\u003ctd\u003eLoad of evaporative condenser\u003cbr\u003e ㆍ250TON x 1.02℃ x 1.1℃\u003cbr\u003e ㆍ280 TON (selected)\u003cbr\u003e ㆍSelection of 280 TON and specificationdetermination with larger value\u003c\/td\u003e\n\u003ctd\u003eLoad of evaporative condenser\u003cbr\u003e ㆍ250TON x 1.4\u003cbr\u003e ㆍ392 TON (selected)\u003cbr\u003e ㆍSelection of 392 TON and specification determination with larger value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cem\u003eDetailed specification sheets are shown in the product images.\u003c\/em\u003e\u003c\/p\u003e","brand":"KyungDong R\u0026H","offers":[{"title":"Default Title","offer_id":58447045427540,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1098\/4649\/5572\/files\/kyungdong-r-h_54512_ksblzl.jpg?v=1795192324","url":"https:\/\/premiumemart.com\/products\/feature-54512","provider":"Premium Emart","version":"1.0","type":"link"}