Explosion proof type indicating temperature switch T990
New

Explosion proof type indicating temperature switch T990

Service intended

This temperature switch is installed with a micro contact, and it is suitable for measuring the temperature of corrosive fluid. Dead band is fixed.

Ambient temperature -20 ~ 60 °C
Nominal diameter 125 mm
Repeatability ±1.0 % of adjustable range
Accuracy ±2.0 % of full scale
Measuring system (SAMA class ⅢB) Organic gas : 0 ~ 200 °C
Inert gas : -200 ~ 700 °C
Working range Maximum scale value

Standard features

Location of stem Bottom connection, surface, Case mounting
Case Silver gray finished aluminium
Cover Silver gray finished aluminium
Capillary Capillary : 1.6/0.2 mm, 316SS
Armored tube : 7.5/5.5 mm, 304SS
Switch form Micro contact type
One SPDT or Two SPDT
One DPDT
Contact rating ■ AC 125 V/250 V, 15 A and DC 30 V, 2 A
DC 125 V, 0.5 A for resistance load
■ AC 125 V/250 V, 15 A and DC 30 V, 1 A
DC 125 V, 0.05 A for inductive load
Stem 8.0, 10.0 and 12.0 mm
316SS and 316L SS
Stem, process connection ⅜", ½", ¾" PT, NPT and PF
Optional Special accuracy, ±1.0 % of full scale
Certificates KCS Ex d IIB+H2 T6

© WISE Control Inc. All rights reserved. ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.

Catalogues

Error product group when enable variant picker

Availability: In stock
Categories: Test · Measurement
Explosion proof type indicating temperature switch T990

Explosion proof type indicating temperature switch T990

$0.00

Explosion proof type indicating temperature switch T990: overview and buying guide

The Explosion proof type indicating temperature switch T990 (model T990) is made by WISE CONTROL and listed in our test · measurement range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.

Frequently asked questions

How much does the Explosion proof type indicating temperature switch T990 cost?

Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.

Can you ship the Explosion proof type indicating temperature switch T990 to my country?

Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.

Is this a genuine WISE CONTROL product?

We purchase directly from WISE CONTROL or its authorised channels and confirm the model and specifications with the manufacturer before ordering.

What is the minimum order quantity?

For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.

Service intended

This temperature switch is installed with a micro contact, and it is suitable for measuring the temperature of corrosive fluid. Dead band is fixed.

Ambient temperature -20 ~ 60 °C
Nominal diameter 125 mm
Repeatability ±1.0 % of adjustable range
Accuracy ±2.0 % of full scale
Measuring system (SAMA class ⅢB) Organic gas : 0 ~ 200 °C
Inert gas : -200 ~ 700 °C
Working range Maximum scale value

Standard features

Location of stem Bottom connection, surface, Case mounting
Case Silver gray finished aluminium
Cover Silver gray finished aluminium
Capillary Capillary : 1.6/0.2 mm, 316SS
Armored tube : 7.5/5.5 mm, 304SS
Switch form Micro contact type
One SPDT or Two SPDT
One DPDT
Contact rating ■ AC 125 V/250 V, 15 A and DC 30 V, 2 A
DC 125 V, 0.5 A for resistance load
■ AC 125 V/250 V, 15 A and DC 30 V, 1 A
DC 125 V, 0.05 A for inductive load
Stem 8.0, 10.0 and 12.0 mm
316SS and 316L SS
Stem, process connection ⅜", ½", ¾" PT, NPT and PF
Optional Special accuracy, ±1.0 % of full scale
Certificates KCS Ex d IIB+H2 T6

© WISE Control Inc. All rights reserved. ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.