Electromagnetic Flowmeters Separated Type F951
Description
The electromagnetic flowmeter can be used to accurately measure the flowrate of liquids, paper pulp, slurry and mineral slurry which has an electrical conductivity greater than 10 µs/cm.
F951 is a flow measurement system consists of a flowmeter primary and remote mounted converter.
Applications
- Facilities in water supply, sewerage, agricultural water, industrial water and waste water
- Petrochemical, alkali salt, chemicals and coolant process.
- Circulating water like cement sludge, coal sludge
- Spoke water, waste water, coolant in pulp, paper mill
- Coolant, seawater circulating, in ship building factories
Specification
| Type | Separate type |
| Size | 15 ~ 1,000A (½ ~ 40") |
| Process connection | Flange type [ANSI, ASME, DIN, JIS, KS, ETC.] |
| Measuring range | 0.2 ~ 10 m/s |
| Accuracy | ±0.5 % Full scale (15 ~ 800A) ±1.0 % Full scale (900A ~ : It needs for site calibration.) |
| Lining | Standard : Hard rubber (0 ~ 60 °C) Option : Teflon (-10 ~ 160 °C) Max. 600A |
| Ambient temperature | -10 ~ 60 °C |
| Conductivity | Standard : ≥ 10 µs/cm Option : ≥5 µs/cm |
| Power supply | Standard : AC 85 ~ 250 V, 50 ~ 60 Hz Option : DC 24 V [2-wire Loop power] |
| Power consumption | Max. 15 VA |
| Display | LCD Display with back light Flowrate : 5-Digit Display Total : 9-Digit Display |
| Output | Analog : DC 4 ~ 20 mA (Isolated) - Active Pulse : Open collector purse Communication : RS485 |
| Protection class | Sensor : IP67 Converter : IP67 |
| Special feature | Self check Empty pipe Enable to reverse flow direction Data logging Error message |
| Electrode signal cable | Standard length : 5 M Option : Max. 30 M |
© WISE Control Inc. All rights reserved. ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Catalogues
Electromagnetic Flowmeters Separated Type F951
Electromagnetic Flowmeters Separated Type F951: overview and buying guide
The Electromagnetic Flowmeters Separated Type F951 (model F951) is made by WISE CONTROL and listed in our test · measurement range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.
Frequently asked questions
How much does the Electromagnetic Flowmeters Separated Type F951 cost?
Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.
Can you ship the Electromagnetic Flowmeters Separated Type F951 to my country?
Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.
Is this a genuine WISE CONTROL product?
We purchase directly from WISE CONTROL or its authorised channels and confirm the model and specifications with the manufacturer before ordering.
What is the minimum order quantity?
For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.
Description
The electromagnetic flowmeter can be used to accurately measure the flowrate of liquids, paper pulp, slurry and mineral slurry which has an electrical conductivity greater than 10 µs/cm.
F951 is a flow measurement system consists of a flowmeter primary and remote mounted converter.
Applications
- Facilities in water supply, sewerage, agricultural water, industrial water and waste water
- Petrochemical, alkali salt, chemicals and coolant process.
- Circulating water like cement sludge, coal sludge
- Spoke water, waste water, coolant in pulp, paper mill
- Coolant, seawater circulating, in ship building factories
Specification
| Type | Separate type |
| Size | 15 ~ 1,000A (½ ~ 40") |
| Process connection | Flange type [ANSI, ASME, DIN, JIS, KS, ETC.] |
| Measuring range | 0.2 ~ 10 m/s |
| Accuracy | ±0.5 % Full scale (15 ~ 800A) ±1.0 % Full scale (900A ~ : It needs for site calibration.) |
| Lining | Standard : Hard rubber (0 ~ 60 °C) Option : Teflon (-10 ~ 160 °C) Max. 600A |
| Ambient temperature | -10 ~ 60 °C |
| Conductivity | Standard : ≥ 10 µs/cm Option : ≥5 µs/cm |
| Power supply | Standard : AC 85 ~ 250 V, 50 ~ 60 Hz Option : DC 24 V [2-wire Loop power] |
| Power consumption | Max. 15 VA |
| Display | LCD Display with back light Flowrate : 5-Digit Display Total : 9-Digit Display |
| Output | Analog : DC 4 ~ 20 mA (Isolated) - Active Pulse : Open collector purse Communication : RS485 |
| Protection class | Sensor : IP67 Converter : IP67 |
| Special feature | Self check Empty pipe Enable to reverse flow direction Data logging Error message |
| Electrode signal cable | Standard length : 5 M Option : Max. 30 M |
© WISE Control Inc. All rights reserved. ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.