Electro Magnetic Flowmeter WEM7100
Overview
Product Overview
The WEM Series is an Electro Magnetic Flow Meter. A flow meter that utilizes Faraday's law to create a magnetic field in a pipe where fluid flows, and based on Fleming's right-hand rule, an electromotive force (EMF) is generated when the fluid flows through this magnetic field, is called an Electro Magnetic Flow Meter.
Since electromagnetic flow meters can measure flow as long as the conductivity is 5μs/cm or more, regardless of temperature, density, pressure, viscosity, or the presence of solids, they are widely used in fields where precise control of fluid flow is required, such as water supply, sewage, wastewater, chemical, oil refining, steel, and paper industries.
ㆍThe fluid must be non-magnetic
ㆍThe fluid must have uniform physical properties
ㆍThe pipe must be full of liquid
ㆍIt must be a conductive liquid with electrical conductivity above a certain value (5μs/cm or more)
Product Feature
ㆍMeasures flow velocity range of -13 to +13 m/sec
ㆍPTFE lining is provided as standard for pipe diameters 100mm or less
ㆍHigh accuracy of ±0.5%
ㆍRS-485 Modbus communication provided
ㆍHigh / Low alarm contact signal
ㆍHART communication available as an option
ㆍSelectable AC / DC power use
ㆍForward/reverse direction measurement and flow display
ㆍRepeatability within 0.1%
ㆍLarge screen backlit LCD
Specification
Product Specification
| Category | WEM7000 | WEM7100 |
| Type | Integrated Round Type | Separated Wall-mounted Type |
|---|---|---|
| Size | 25 ~ 500mm | |
| Pipe Material | STS304 | |
| Case material | Body - STS304 ,STEEL EGI | |
| Cast Aluminum, | ABS | |
| Lining material | 25 ~ 100A : Teflon (PTFE, ETFE) - Standard | |
| 125 ~ 500A : Hard Rubber - Standard | ||
| Electrode material | 25A ~ 500A : STS316L - Standard Option : Tantalium, Platinium, Hastelloy-C & Other |
|
| Process connection | Flange type KS10K(JIS10K) Option : KSD4308, ANSI, DIN… (etc) | |
| Measuring range | -13㎧ ~ 13㎧ | |
| Accuracy | ± 0.1 ~ 0.3 ㎧ ±0.25% FS / ± 0.3 ~ 13 ㎧ ±0.5% FS | |
| Fluid temperature | PTFE (Teflon) -5℃ ~ +160℃ | |
| Hard Rubber -5℃ ~ + 60℃ | ||
| Ambient temperature | -25℃ ~ +60℃ | |
| Power supply | Free Voltage (AC85 ~ 250V), DC20~36V | |
| Display | Graphic LCD display with back light | |
| Out put | Analog - DC4 ~ 20mA (max. road 750Ω or less) | |
| Pulse - DC 24V ( Dry Contact ) | ||
| Digital - RS485 Modbus | ||
| Alarm - High/Low Value Selection(2 channel) | ||
| Cable length | None | 10m provided as standard |
| Option | HART communication | |
Electro Magnetic Flowmeter WEM7100
Electro Magnetic Flowmeter WEM7100: overview and buying guide
The Electro Magnetic Flowmeter WEM7100 (model WEM7100) is made by WinTEC and listed in our hydraulic · fluid range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.
Frequently asked questions
How much does the Electro Magnetic Flowmeter WEM7100 cost?
Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.
Can you ship the Electro Magnetic Flowmeter WEM7100 to my country?
Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.
Is this a genuine WinTEC product?
We purchase directly from WinTEC or its authorised channels and confirm the model and specifications with the manufacturer before ordering.
What is the minimum order quantity?
For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.
Overview
Product Overview
The WEM Series is an Electro Magnetic Flow Meter. A flow meter that utilizes Faraday's law to create a magnetic field in a pipe where fluid flows, and based on Fleming's right-hand rule, an electromotive force (EMF) is generated when the fluid flows through this magnetic field, is called an Electro Magnetic Flow Meter.
Since electromagnetic flow meters can measure flow as long as the conductivity is 5μs/cm or more, regardless of temperature, density, pressure, viscosity, or the presence of solids, they are widely used in fields where precise control of fluid flow is required, such as water supply, sewage, wastewater, chemical, oil refining, steel, and paper industries.
ㆍThe fluid must be non-magnetic
ㆍThe fluid must have uniform physical properties
ㆍThe pipe must be full of liquid
ㆍIt must be a conductive liquid with electrical conductivity above a certain value (5μs/cm or more)
Product Feature
ㆍMeasures flow velocity range of -13 to +13 m/sec
ㆍPTFE lining is provided as standard for pipe diameters 100mm or less
ㆍHigh accuracy of ±0.5%
ㆍRS-485 Modbus communication provided
ㆍHigh / Low alarm contact signal
ㆍHART communication available as an option
ㆍSelectable AC / DC power use
ㆍForward/reverse direction measurement and flow display
ㆍRepeatability within 0.1%
ㆍLarge screen backlit LCD
Specification
Product Specification
| Category | WEM7000 | WEM7100 |
| Type | Integrated Round Type | Separated Wall-mounted Type |
|---|---|---|
| Size | 25 ~ 500mm | |
| Pipe Material | STS304 | |
| Case material | Body - STS304 ,STEEL EGI | |
| Cast Aluminum, | ABS | |
| Lining material | 25 ~ 100A : Teflon (PTFE, ETFE) - Standard | |
| 125 ~ 500A : Hard Rubber - Standard | ||
| Electrode material | 25A ~ 500A : STS316L - Standard Option : Tantalium, Platinium, Hastelloy-C & Other |
|
| Process connection | Flange type KS10K(JIS10K) Option : KSD4308, ANSI, DIN… (etc) | |
| Measuring range | -13㎧ ~ 13㎧ | |
| Accuracy | ± 0.1 ~ 0.3 ㎧ ±0.25% FS / ± 0.3 ~ 13 ㎧ ±0.5% FS | |
| Fluid temperature | PTFE (Teflon) -5℃ ~ +160℃ | |
| Hard Rubber -5℃ ~ + 60℃ | ||
| Ambient temperature | -25℃ ~ +60℃ | |
| Power supply | Free Voltage (AC85 ~ 250V), DC20~36V | |
| Display | Graphic LCD display with back light | |
| Out put | Analog - DC4 ~ 20mA (max. road 750Ω or less) | |
| Pulse - DC 24V ( Dry Contact ) | ||
| Digital - RS485 Modbus | ||
| Alarm - High/Low Value Selection(2 channel) | ||
| Cable length | None | 10m provided as standard |
| Option | HART communication | |