Dry Vacuum Pump PROVAC(KDPH)-Series
Features
· Dry type of operation without oil and water
· SIMPLE stage / simple DESIGN
· No use of oil and water
· Fast discharge of process gas and shorter gas pass time in casing
· High volume efficiency with use of the screw type of rotor
Advantages to the Users
· Clean and pure without hunting in performance
· Low utility cost with the reduction of power
· Various coating applicable to prevent from toxic, corrosive and condensate gases.
· Very low discharge temperature
· Increase of capacity and vacuum level
· Small installation space with compact design
· Easy to install with C-Flange and can reduce noise and vibration easily. No need to align the shaft.
Application
· Chemistry & Petrochemical - Solvent recovery, evaporation, drying, molecular distillation, dehydration, Degassing, Defoaming, Deodorization, Esterification, polymerization, Forming, plasticizer, surfactant
· Food - lyophilization, packing
· Electric & electronic - Thin film deposition, ETCHER, ION IMPLANTATION, Encapsulation
· SPECIALTY CHEMICAL MANUFACTURING
· Producing pharmaceuticals
· Etc.
Specification
| Specification / Model No. | PROVAC 130 | PROVAC 250 |
PROVAC 350 |
PROVAC 450 |
PROVAC 850 |
PROVAC 1500 |
PROVAC 3000 |
|
| Nominal Displacement (M/Hr) 50Hz/60Hz | 120 (100) m/hr | 155/187 | 267/320 | 358/430 | 625/750 | 1300/1500 | 2250/2700 | |
| Ultimate Pressure (50/60Hz) | 1.3x10-2/ 6.6x10-3kPa(0.1/0.05Torr) |
6.6x10-3/ 2.7x10-3kPa(0.05/0.02Torr) |
4.0x10-3/ 2.7x10-3kPa(0.03/0.02Torr) |
4.0x10-3/ 2.7x10-3kPa(0.03/0.02Torr) |
4.0x10-3/ 1.3x10-3kPa(0.03/0.01Torr) |
1.3x10-2/ 6.6x10-3kPa(0.1/0.05Torr) |
1.3x10-2/ 6.6x10-3kPa(0.1/0.05Torr) |
|
| Power Kw (50Hz/60Hz) | 2.2/3.7 | 3.7/5.0 | 7.5/10.0 | 11.0/15.0 | 15.0/20.0 | 37.0/50.0 | 55.0/75.0 | |
| Rotation (RPM) 50Hz/60Hz | 2900/3500 | 2900/3500 | 2900/3500 | 2900/3500 | 2900/3500 | 1450/1750 | 1450/1750 | |
| Port size | Suction (A) | 40 | 40 | 40 | 65 | 100 | 125 | 150 |
| Discharge (A) | 40 | 40 | 50 | 50 | 65 | 80 | 100 | |
| Min. Cooling Water (l/min) | 3 | 5 | 8 | 11 | 20 | 36 | 48 | |
| Weight (Kg, Bare Shaft) | 150Kg | 220Kg | 300Kg | 400Kg | 600Kg | 1350Kg | 1650Kg | |
* Specifications are subject to change without notice to improve product quality.
Performance Curve
PROVAC 130
* The above performance curves are subject to change according to the actual conditions of process.
PROVAC 250
* The above performance curves are subject to change according to the actual conditions of process.
PROVAC 350
* The above performance curves are subject to change according to the actual conditions of process.
PROVAC 450
* The above performance curves are subject to change according to the actual conditions of process.
PROVAC 850
* The above performance curves are subject to change according to the actual conditions of process.
PROVAC 1500
* The above performance curves are subject to change according to the actual conditions of process.
PROVAC 3000
* The above performance curves are subject to change according to the actual conditions of process.
Dimension
| SIZE PUMP MODEL | A | B | C | D | E | F | G | H | J | Port Size(A) | |
| SUC | DIS | ||||||||||
| PROVAC P250 | 744 | 228 | 1100 | 243 | 422 | 835 | 766 | 40 | 40 | ||
| PROVAC P350 | 860 | 262 | 1240 | 263 | 484 | 846 | 767 | 50 | 40 | ||
| PROVAC P450 | 960 | 280 | 1496 | 277 | 501 | 941 | 873 | 65 | 50 | ||
| PROVAC P850 | 1054 | 322 | 1676 | 297 | 652 | 1021 | 989 | 100 | 65 | ||
| PROVAC P1500 | 586 | 586 | 586 | 2080 | 455 | 806 | 760 | 1250 | 1415 | 100 | 65 |
| PROVAC P3000 | 664 | 683 | 680 | 2565 | 515 | 780 | 1044 | 1465 | 1505 | 150 | 100 |
Detailed specification sheets are shown in the product images.
Catalogues
Dry Vacuum Pump PROVAC(KDPH)-Series
Dry Vacuum Pump PROVAC(KDPH)-Series: overview and buying guide
The Dry Vacuum Pump PROVAC(KDPH)-Series (model PROVAC(KDPH)-Series) is made by KOWEL PRECISION and listed in our hydraulic · fluid range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.
Frequently asked questions
How much does the Dry Vacuum Pump PROVAC(KDPH)-Series cost?
Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.
Can you ship the Dry Vacuum Pump PROVAC(KDPH)-Series to my country?
Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.
Is this a genuine KOWEL PRECISION product?
We purchase directly from KOWEL PRECISION or its authorised channels and confirm the model and specifications with the manufacturer before ordering.
What is the minimum order quantity?
For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.
Features
· Dry type of operation without oil and water
· SIMPLE stage / simple DESIGN
· No use of oil and water
· Fast discharge of process gas and shorter gas pass time in casing
· High volume efficiency with use of the screw type of rotor
Advantages to the Users
· Clean and pure without hunting in performance
· Low utility cost with the reduction of power
· Various coating applicable to prevent from toxic, corrosive and condensate gases.
· Very low discharge temperature
· Increase of capacity and vacuum level
· Small installation space with compact design
· Easy to install with C-Flange and can reduce noise and vibration easily. No need to align the shaft.
Application
· Chemistry & Petrochemical - Solvent recovery, evaporation, drying, molecular distillation, dehydration, Degassing, Defoaming, Deodorization, Esterification, polymerization, Forming, plasticizer, surfactant
· Food - lyophilization, packing
· Electric & electronic - Thin film deposition, ETCHER, ION IMPLANTATION, Encapsulation
· SPECIALTY CHEMICAL MANUFACTURING
· Producing pharmaceuticals
· Etc.
Specification
| Specification / Model No. | PROVAC 130 | PROVAC 250 |
PROVAC 350 |
PROVAC 450 |
PROVAC 850 |
PROVAC 1500 |
PROVAC 3000 |
|
| Nominal Displacement (M/Hr) 50Hz/60Hz | 120 (100) m/hr | 155/187 | 267/320 | 358/430 | 625/750 | 1300/1500 | 2250/2700 | |
| Ultimate Pressure (50/60Hz) | 1.3x10-2/ 6.6x10-3kPa(0.1/0.05Torr) |
6.6x10-3/ 2.7x10-3kPa(0.05/0.02Torr) |
4.0x10-3/ 2.7x10-3kPa(0.03/0.02Torr) |
4.0x10-3/ 2.7x10-3kPa(0.03/0.02Torr) |
4.0x10-3/ 1.3x10-3kPa(0.03/0.01Torr) |
1.3x10-2/ 6.6x10-3kPa(0.1/0.05Torr) |
1.3x10-2/ 6.6x10-3kPa(0.1/0.05Torr) |
|
| Power Kw (50Hz/60Hz) | 2.2/3.7 | 3.7/5.0 | 7.5/10.0 | 11.0/15.0 | 15.0/20.0 | 37.0/50.0 | 55.0/75.0 | |
| Rotation (RPM) 50Hz/60Hz | 2900/3500 | 2900/3500 | 2900/3500 | 2900/3500 | 2900/3500 | 1450/1750 | 1450/1750 | |
| Port size | Suction (A) | 40 | 40 | 40 | 65 | 100 | 125 | 150 |
| Discharge (A) | 40 | 40 | 50 | 50 | 65 | 80 | 100 | |
| Min. Cooling Water (l/min) | 3 | 5 | 8 | 11 | 20 | 36 | 48 | |
| Weight (Kg, Bare Shaft) | 150Kg | 220Kg | 300Kg | 400Kg | 600Kg | 1350Kg | 1650Kg | |
* Specifications are subject to change without notice to improve product quality.
Performance Curve
PROVAC 130
* The above performance curves are subject to change according to the actual conditions of process.
PROVAC 250
* The above performance curves are subject to change according to the actual conditions of process.
PROVAC 350
* The above performance curves are subject to change according to the actual conditions of process.
PROVAC 450
* The above performance curves are subject to change according to the actual conditions of process.
PROVAC 850
* The above performance curves are subject to change according to the actual conditions of process.
PROVAC 1500
* The above performance curves are subject to change according to the actual conditions of process.
PROVAC 3000
* The above performance curves are subject to change according to the actual conditions of process.
Dimension
| SIZE PUMP MODEL | A | B | C | D | E | F | G | H | J | Port Size(A) | |
| SUC | DIS | ||||||||||
| PROVAC P250 | 744 | 228 | 1100 | 243 | 422 | 835 | 766 | 40 | 40 | ||
| PROVAC P350 | 860 | 262 | 1240 | 263 | 484 | 846 | 767 | 50 | 40 | ||
| PROVAC P450 | 960 | 280 | 1496 | 277 | 501 | 941 | 873 | 65 | 50 | ||
| PROVAC P850 | 1054 | 322 | 1676 | 297 | 652 | 1021 | 989 | 100 | 65 | ||
| PROVAC P1500 | 586 | 586 | 586 | 2080 | 455 | 806 | 760 | 1250 | 1415 | 100 | 65 |
| PROVAC P3000 | 664 | 683 | 680 | 2565 | 515 | 780 | 1044 | 1465 | 1505 | 150 | 100 |
Detailed specification sheets are shown in the product images.









