Overview

The New Digital Totalizing Flowmeter consists of a base pipe with an orifice plate, a 3-way valve, a differential pressure sensor, and a flow transmitter. This flowmeter can be installed directly into the line without the need for separate pressure tapping pipes, resulting in low installation costs. It displays both current and cumulative readings on-site and offers various functions such as 4–20 mA and pulse outputs, making it convenient to use. With a built-in Smart Transmitter, it is a field-installable flowmeter with a wide range of settings.

Features

  • The 3-Way Orifice Valve features an integrated flow indicator and totalizer, making installation simple and reducing construction costs.

  • The on-site display and totalizer model allows you to view instantaneous flow and total flow once power is connected.

  • Equipped with a microprocessor, it allows you to program operating conditions to suit your specific application.

  • It can be installed in any orientation, whether horizontal or vertical.

  • Explosion-proof model available (optional)

  • With the use of connectors, it can be used with fluids under high-temperature and high-pressure conditions.

  • Explosion-proof type: Exd IIB T6

Selection of Type

Structural diagram

Flow range

SIZE

Water(m³/h)

AIR(Nm³/h) 760mmHg(A)20℃

Flow rate (Min~Max)

Flow rate (Min~Max)

⅜B

10A

0.1~0.5

0.08~4

½B

15A

0.2~1.0

2~10

¾B

20A

0.5~2.5

5~25

1B

25A

1.0~5.0

10~50

1¼B

32A

2~10

12~60

1½B

40A

3~15

20~100

2B

50A

5~25

40~200

2½B

65A

7~35

60~300

3B

80A

10~50

80~400

4B

100A

16~80

160~800

5B

125A

25~125

250~1250

6B

150A

30~200

350~1700

8B

200A

60~320

600~2800

10B

250A

90~480

900~5000

12B

300A

160~820

1600~7800

14B

350A

200~1000

2000~9500

16B

400A

300~1500

3000~14500

18B

450A

400~2000

4000~19000

20B

500A

500~2500

5000~24000

  • The pressure and temperature of the gas are 1 atm, 20°C.

  • For pressure PKgf/cm2, multiply this table by P+1.

  • The table above is the standard flow rate, and please discuss the other flow range with the headquarters.

  • Please refer to page 11 for Length.

Standard specification

category

specification

Applied fluid

Liquid, Gas, Steam

Flow range

1:7 (standard), 1:5 (steam and special specifications)

highest operating pressure

20 kgf/cm2G (but for steam, 10 kgf/cm2G)

Fluid temperature

-20 to 120°C (optional up to 230°C)

ambient temperature

-10~50℃

detection unit

measured differential pressure

Low-pressure type : 0~500mmH2 O

Medium-pressure type : 0~4,000mmH2 O

High-pressure type : 0~16,000mmH2 O

an on-site indicator

instantaneous flow

4Digit

integrated flow rate

10Digit (999999999 count)

an output signal

current output

4-20mAC (maximum load resistance 600Ω)

Pulse Output
(RS485 Communication Output (Optional)

Insulated Open Collector Pulse (NPN method)
Rated output: Max DC50V / 50mA
Maximum frequency: 5Hz or less

Accuracy

For liquids: ±2.0 F.S
For gas: ±2.0 F.S

Power

Input voltage

AC 110/220V, 50/60Hz

Power consumption

4VA(Max)

indication structure

IP65 / Exd ⅡIBT6

Line connection

1/2 PT

Weight

5.25Kg

Materials Used

Part Name

Material

Material

Material

Base Socket

SUS304

SUS316

PVC

Orifice Plate

SUS304

SUS316

PVC

Indicator

Aluminum Casting (ADC 12)

Differential Pressure Sensor

Diaphragm

SUS316L

Other Wetted Parts

SUS316L

O-RING

VITON

Filling Fluid

Silicone Oil

Pressure Transmission Section

Body

SCS314

Components

SUS316

O-RING

TEFLON

Standard Specifications

Installation Precautions

1. The straight pipe sections for digital differential area flow meters are as follows.

Valve and T-fitting (D)

Valve (D)

Upstream

10(6)

14

downstream

3

3

2. Installation Location

  • Avoid locations subject to vibration or direct sunlight.

  • For PVC, ensure that the surface temperature does not exceed 50°C.

3. When opening the neutral valve for zero adjustment, be sure to open the STOP valve first before opening the valve.

4. When using fluids under high-temperature or high-pressure conditions, be sure to use a connector pipe.

5. During operation, keep the neutral valve of the three-way valve closed, and fully open the valves on the High and Low sides.

How to Operate a 3-Way Valve

Keep valves 1 and 3 fully open at all times. / Keep the neutral valve (No. 2) closed at all times.

Detailed specification sheets are shown in the product images.

Catalogues

Error product group when enable variant picker

Availability: In stock
Digital Totalizing Flowmeter ADG

Digital Totalizing Flowmeter ADG

$0.00

Digital Totalizing Flowmeter ADG: overview and buying guide

The Digital Totalizing Flowmeter ADG (model ADG) is made by AUTOFLOW and listed in our chemical range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.

Frequently asked questions

How much does the Digital Totalizing Flowmeter ADG cost?

Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.

Can you ship the Digital Totalizing Flowmeter ADG to my country?

Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.

Is this a genuine AUTOFLOW product?

We purchase directly from AUTOFLOW or its authorised channels and confirm the model and specifications with the manufacturer before ordering.

What is the minimum order quantity?

For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.

Orifice Type Flowmeter

Overview

The New Digital Totalizing Flowmeter consists of a base pipe with an orifice plate, a 3-way valve, a differential pressure sensor, and a flow transmitter. This flowmeter can be installed directly into the line without the need for separate pressure tapping pipes, resulting in low installation costs. It displays both current and cumulative readings on-site and offers various functions such as 4–20 mA and pulse outputs, making it convenient to use. With a built-in Smart Transmitter, it is a field-installable flowmeter with a wide range of settings.

Features

  • The 3-Way Orifice Valve features an integrated flow indicator and totalizer, making installation simple and reducing construction costs.

  • The on-site display and totalizer model allows you to view instantaneous flow and total flow once power is connected.

  • Equipped with a microprocessor, it allows you to program operating conditions to suit your specific application.

  • It can be installed in any orientation, whether horizontal or vertical.

  • Explosion-proof model available (optional)

  • With the use of connectors, it can be used with fluids under high-temperature and high-pressure conditions.

  • Explosion-proof type: Exd IIB T6

Selection of Type

Structural diagram

Flow range

SIZE

Water(m³/h)

AIR(Nm³/h) 760mmHg(A)20℃

Flow rate (Min~Max)

Flow rate (Min~Max)

⅜B

10A

0.1~0.5

0.08~4

½B

15A

0.2~1.0

2~10

¾B

20A

0.5~2.5

5~25

1B

25A

1.0~5.0

10~50

1¼B

32A

2~10

12~60

1½B

40A

3~15

20~100

2B

50A

5~25

40~200

2½B

65A

7~35

60~300

3B

80A

10~50

80~400

4B

100A

16~80

160~800

5B

125A

25~125

250~1250

6B

150A

30~200

350~1700

8B

200A

60~320

600~2800

10B

250A

90~480

900~5000

12B

300A

160~820

1600~7800

14B

350A

200~1000

2000~9500

16B

400A

300~1500

3000~14500

18B

450A

400~2000

4000~19000

20B

500A

500~2500

5000~24000

  • The pressure and temperature of the gas are 1 atm, 20°C.

  • For pressure PKgf/cm2, multiply this table by P+1.

  • The table above is the standard flow rate, and please discuss the other flow range with the headquarters.

  • Please refer to page 11 for Length.

Standard specification

category

specification

Applied fluid

Liquid, Gas, Steam

Flow range

1:7 (standard), 1:5 (steam and special specifications)

highest operating pressure

20 kgf/cm2G (but for steam, 10 kgf/cm2G)

Fluid temperature

-20 to 120°C (optional up to 230°C)

ambient temperature

-10~50℃

detection unit

measured differential pressure

Low-pressure type : 0~500mmH2 O

Medium-pressure type : 0~4,000mmH2 O

High-pressure type : 0~16,000mmH2 O

an on-site indicator

instantaneous flow

4Digit

integrated flow rate

10Digit (999999999 count)

an output signal

current output

4-20mAC (maximum load resistance 600Ω)

Pulse Output
(RS485 Communication Output (Optional)

Insulated Open Collector Pulse (NPN method)
Rated output: Max DC50V / 50mA
Maximum frequency: 5Hz or less

Accuracy

For liquids: ±2.0 F.S
For gas: ±2.0 F.S

Power

Input voltage

AC 110/220V, 50/60Hz

Power consumption

4VA(Max)

indication structure

IP65 / Exd ⅡIBT6

Line connection

1/2 PT

Weight

5.25Kg

Materials Used

Part Name

Material

Material

Material

Base Socket

SUS304

SUS316

PVC

Orifice Plate

SUS304

SUS316

PVC

Indicator

Aluminum Casting (ADC 12)

Differential Pressure Sensor

Diaphragm

SUS316L

Other Wetted Parts

SUS316L

O-RING

VITON

Filling Fluid

Silicone Oil

Pressure Transmission Section

Body

SCS314

Components

SUS316

O-RING

TEFLON

Standard Specifications

Installation Precautions

1. The straight pipe sections for digital differential area flow meters are as follows.

Valve and T-fitting (D)

Valve (D)

Upstream

10(6)

14

downstream

3

3

2. Installation Location

  • Avoid locations subject to vibration or direct sunlight.

  • For PVC, ensure that the surface temperature does not exceed 50°C.

3. When opening the neutral valve for zero adjustment, be sure to open the STOP valve first before opening the valve.

4. When using fluids under high-temperature or high-pressure conditions, be sure to use a connector pipe.

5. During operation, keep the neutral valve of the three-way valve closed, and fully open the valves on the High and Low sides.

How to Operate a 3-Way Valve

Keep valves 1 and 3 fully open at all times. / Keep the neutral valve (No. 2) closed at all times.

Detailed specification sheets are shown in the product images.