Digital Display Flow Meter RW3
Digital Display Flow Meter RW3
New
Digital Display Flow Meter RW3
Digital Display Flow Meter RW3

Digital Display Flow Meter RW3

The New digital display flow meter is a 2 wire loop powered 4-20mA DC indicator that displays a flow rate and total. On-screen engineering units are easily configured. Password protection and 16 bit A/D resolution. A New built in wet/wet differential pressure sensor is protected by an isolated stainless steel diaphragm and provides a 4-20mA DC signal to the display. The enclosure is IP67 / NEMA 4X rated which further enhances this models capability. Available in threaded or flanged connection and bronze or stainless steel construction.

Specification

Standard Specifications :

Accuracy : ± 3% F.S.

Repeatability : ± 1% F.S.

Pressure Max. : 180 psig (12.6 kg/㎠)

Pressure Min. : 10 psig (0.67 kg/㎠)

Temp. Max. : 212ºF (100ºC)

Temp. Min. : -30ºF (-34ºC) 


IP67 / NEMA 4X Rated Enclosure 

Electrical Rating :

Power Input : 100mA, 24Vdc power supply 20-30Vdc (Not Included)
                       Input loop powered from 4-20mA signal. Voltage drop max. 2.6V 

Display:

Rate Display :  High intensity reflective numeric and alpha numeric LCD, UV resistant  User definable,

                      8 times/sec - 30 secs. 

                      Password Protection
                      7 and 11 digit various symbols and measuring units 

Environmental :

Operating Temperature : -30ºF (-34ºC) to 212ºF (100ºC)

Humidity : 0-90% Noncondensing 


Accuracy : 0.5% F.S. (Non-linearity, Repeatability and Hysteresis

Stability : 0.5%F.S./year 

Signal Inputs : Full Scale Range: 4 to 20 mA DC
                         Loop Voltage Drop: 2.6 Volts Max. at 20mA
                         Update Time: 4 times/sec.
                         Span: 0.001/999,999 with available decimal position
                         16 Bit resolution, error < 0.01mA/+- 0.05% F.S.
                         Low cutoff supplied to inhibit indications at low flow rates

Signal Ouput : The pulse output transmitting accumulated total
                        Type : one passive transistor output (NPN)
                        Max. 500Hz pulse length user definable between 1 msec up to 10 sec. 

Calibration & Operation : Input Scaling : Via front keypad
                                         Decimal Point : Via front keypad
                                         Reset Input : Via front keypad
                                         Keypad : 3 tactile feedback keys

Ordering Information

Step 1 - Select a Product Category (i.e. Flowmenters, Flow Transmitters, etc.) and Product
            (i.e. Liquid, Gas, etc.)
Step 2 - Select the item # which defines the (a) body size, (b) connection type and (c) material of
            construction and press the "Request Information" button to continue to Step 3.
        A) Body Size - Pipe size at the meter inlet.            
        B) Connection Type (Series) --                 
            7 - Threaded units with FNPT connection Standard. FBSP threads Bronze and Monel only.
            8 - Wafer units standard 150 # and 300 # class flanges (or international equivalent).
        C) Material -                   
   1 = Bronze          2 = Monel            3 = Stainless Steel    
Step 3 - Select (d) flow direction, (e) flow range, (f) Options (Required Fidlds*). Complete the information
            section name, address, phone, email, etc. and submit for request for quote or for additional product
            information.
        D) Flow Direction - Select L, R, VUL, VUR, VDL, VDR.        
        E) Flow Range (full scale) - Select from available flow rate list specific to each item #.
        F) Options (if required) - Select from table of options specific to each item #.
Note : Not all options can be combined, consult the factory for details.
         Example : See complete model number below.

Product Category - Flow Meters for Liquids and Gases (Gas) 

Detailed specification sheets are shown in the product images.

Catalogues

Error product group when enable variant picker

Availability: In stock
Digital Display Flow Meter RW3

Digital Display Flow Meter RW3

$0.00

Digital Display Flow Meter RW3: overview and buying guide

The Digital Display Flow Meter RW3 (model RW3) is made by M&C ENGINEERING and listed in our test · measurement range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.

Frequently asked questions

How much does the Digital Display Flow Meter RW3 cost?

Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.

Can you ship the Digital Display Flow Meter RW3 to my country?

Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.

Is this a genuine M&C ENGINEERING product?

We purchase directly from M&C ENGINEERING or its authorised channels and confirm the model and specifications with the manufacturer before ordering.

What is the minimum order quantity?

For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.

The New digital display flow meter is a 2 wire loop powered 4-20mA DC indicator that displays a flow rate and total. On-screen engineering units are easily configured. Password protection and 16 bit A/D resolution. A New built in wet/wet differential pressure sensor is protected by an isolated stainless steel diaphragm and provides a 4-20mA DC signal to the display. The enclosure is IP67 / NEMA 4X rated which further enhances this models capability. Available in threaded or flanged connection and bronze or stainless steel construction.

Specification

Standard Specifications :

Accuracy : ± 3% F.S.

Repeatability : ± 1% F.S.

Pressure Max. : 180 psig (12.6 kg/㎠)

Pressure Min. : 10 psig (0.67 kg/㎠)

Temp. Max. : 212ºF (100ºC)

Temp. Min. : -30ºF (-34ºC) 


IP67 / NEMA 4X Rated Enclosure 

Electrical Rating :

Power Input : 100mA, 24Vdc power supply 20-30Vdc (Not Included)
                       Input loop powered from 4-20mA signal. Voltage drop max. 2.6V 

Display:

Rate Display :  High intensity reflective numeric and alpha numeric LCD, UV resistant  User definable,

                      8 times/sec - 30 secs. 

                      Password Protection
                      7 and 11 digit various symbols and measuring units 

Environmental :

Operating Temperature : -30ºF (-34ºC) to 212ºF (100ºC)

Humidity : 0-90% Noncondensing 


Accuracy : 0.5% F.S. (Non-linearity, Repeatability and Hysteresis

Stability : 0.5%F.S./year 

Signal Inputs : Full Scale Range: 4 to 20 mA DC
                         Loop Voltage Drop: 2.6 Volts Max. at 20mA
                         Update Time: 4 times/sec.
                         Span: 0.001/999,999 with available decimal position
                         16 Bit resolution, error < 0.01mA/+- 0.05% F.S.
                         Low cutoff supplied to inhibit indications at low flow rates

Signal Ouput : The pulse output transmitting accumulated total
                        Type : one passive transistor output (NPN)
                        Max. 500Hz pulse length user definable between 1 msec up to 10 sec. 

Calibration & Operation : Input Scaling : Via front keypad
                                         Decimal Point : Via front keypad
                                         Reset Input : Via front keypad
                                         Keypad : 3 tactile feedback keys

Ordering Information

Step 1 - Select a Product Category (i.e. Flowmenters, Flow Transmitters, etc.) and Product
            (i.e. Liquid, Gas, etc.)
Step 2 - Select the item # which defines the (a) body size, (b) connection type and (c) material of
            construction and press the "Request Information" button to continue to Step 3.
        A) Body Size - Pipe size at the meter inlet.            
        B) Connection Type (Series) --                 
            7 - Threaded units with FNPT connection Standard. FBSP threads Bronze and Monel only.
            8 - Wafer units standard 150 # and 300 # class flanges (or international equivalent).
        C) Material -                   
   1 = Bronze          2 = Monel            3 = Stainless Steel    
Step 3 - Select (d) flow direction, (e) flow range, (f) Options (Required Fidlds*). Complete the information
            section name, address, phone, email, etc. and submit for request for quote or for additional product
            information.
        D) Flow Direction - Select L, R, VUL, VUR, VDL, VDR.        
        E) Flow Range (full scale) - Select from available flow rate list specific to each item #.
        F) Options (if required) - Select from table of options specific to each item #.
Note : Not all options can be combined, consult the factory for details.
         Example : See complete model number below.

Product Category - Flow Meters for Liquids and Gases (Gas) 

Detailed specification sheets are shown in the product images.

Catalogues