Coriolis Mass Flowmeter
Coriolis Mass Flowmeter
Principle Description
Mass Flowmeter based on the Coriolis principle can directly measure the process fluid mass flow rate, density and temperature. When acceleration is applied to the rotating mass that is made up of the fluid flowing through the tubes in the sensor, gyroscopic deflections of the flow sensing tubes occur. These gyroscopic deflections are converted into signals that are related to the mass flow through the flow sensor.The signals are fed directly to the converter. The fluid density is also measured by sensing changes in the frequency of oscillation of the flow tubes, The Platinum Resistance Temperature Detector is located in the sensor. The other parameters of the process fluid can be obtained on the basis of the mass rate, density and temperature.
The Safety barrier board provides an intrinsical sale interface for flow meter use in hazardous areas. The converter interface board provides excitation to the flow sensor and signal conditioning of flow sensor outputs prior to digital processing. The processor board provides digital signal processing of the signals from the flow sensor interfaces and calculates mass flow, volumetric flow, density, and temperature. The processor board controls the LCD display and monitors the keypad, and also monitors or controls the other 10 signals that pass through the I/O part.
The processor board outputs a frequency that is proportional to the flow rate : 0 to 10 kHz, 24VDC square wave signal. The processor board outputs a 4 to 20mA signal that is proportional to the value of the selected variable. The processor board can also make communication according to the agreement by the serial interface.
Specifications
Materials |
Flow Tube, SS316L ; Housing, SS304 |
|---|---|
Meter Sizes |
DN3-DN200 |
Fluid Temperture |
-50℃~200℃ |
Pressure Rating |
4.0MPA, 10.0MPA, 16.0MPA, 25.0MPA, 42.0MPA, others on request |
Ambient Temperature |
Primary : -40℃~65℃ ; Converter : -15℃~55℃ |
Accuracy |
0.15%, 0.2%, 0.5% |
Flow Ranges Ratio |
1 : 20 |
Process Connections |
Flanges, Screw thread |
Supply Power |
AC 85~265V or DC 18~36V |
Power |
≤10W |
Output Signal |
4~20mA |
Frequency Output |
0~10KHz |
Communications |
RS485, Modbus |
Protection Class |
IP67 |
Explosions Proof Design |
Exd[ib]ⅡCT4 |
Measuring Ranges, Flow
Meter Size(mm) |
Ranges (kg/min) |
Zero drift (kg/min) |
|---|---|---|
|
3 6 10 |
0~3 0~15 0~30 |
0.0011 0.004 0.006 |
|
20 25 32 |
0~70 0~200 0~360 |
0.014 0.04 0.07 |
|
40 50 80 |
0~500 0~1200 0~3000 |
0.10 0.24 0.52 |
|
100 150 200 |
0~5000 0~11000 0~18000 |
0.71 1.21 1.9 |
Dimensions
Sensor :
PRESSURE Rating |
Diameter |
A |
B |
C |
D |
Process Connections |
Weight kg |
|---|---|---|---|---|---|---|---|
4MPa |
3 |
190 |
180 |
50 |
M14×1.5 |
3 |
|
6 |
222 |
165 |
50 |
M22×1.5 |
3.7 |
||
10 |
305 |
200 |
60 |
M22×1.5 |
5.5 |
||
15 |
326 |
370 |
300 |
84 |
Flange Connection Flange standards : JB/T82 1-94 |
14 |
|
25 |
446 |
440 |
385 |
104 |
21 |
||
32 |
460 |
490 |
420 |
94 |
28 |
||
40 |
566 |
562 |
444 |
124 |
36 |
||
50 |
646 |
760 |
525 |
144 |
60 |
||
80 |
776 |
943 |
592 |
206 |
116 |
||
100 |
864 |
1350 |
748 |
276 |
175 |
||
150 |
1092 |
1830 |
1100 |
412 |
360 |
||
200 |
1320 |
2136 |
1214 |
530 |
520 |
||
25MPa |
10 |
305 |
200 |
60 |
M22×1.5 |
6 |
|
16MPa |
25 |
480 |
440 |
385 |
104 |
Flange Connection Flange standards : JB/T82 1-94 |
22 |
10MPa |
40 |
610 |
562 |
444 |
124 |
37 |
※ Please contact our Sales Department for detailed specifications.
Detailed specification sheets are shown in the product images.
Coriolis Mass Flowmeter
Coriolis Mass Flowmeter: overview and buying guide
The Coriolis Mass Flowmeter is made by AUTOFLOW and listed in our chemical range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.
Frequently asked questions
How much does the Coriolis Mass Flowmeter cost?
Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.
Can you ship the Coriolis Mass Flowmeter to my country?
Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.
Is this a genuine AUTOFLOW product?
We purchase directly from AUTOFLOW or its authorised channels and confirm the model and specifications with the manufacturer before ordering.
What is the minimum order quantity?
For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.
Coriolis Mass Flowmeter
Principle Description
Mass Flowmeter based on the Coriolis principle can directly measure the process fluid mass flow rate, density and temperature. When acceleration is applied to the rotating mass that is made up of the fluid flowing through the tubes in the sensor, gyroscopic deflections of the flow sensing tubes occur. These gyroscopic deflections are converted into signals that are related to the mass flow through the flow sensor.The signals are fed directly to the converter. The fluid density is also measured by sensing changes in the frequency of oscillation of the flow tubes, The Platinum Resistance Temperature Detector is located in the sensor. The other parameters of the process fluid can be obtained on the basis of the mass rate, density and temperature.
The Safety barrier board provides an intrinsical sale interface for flow meter use in hazardous areas. The converter interface board provides excitation to the flow sensor and signal conditioning of flow sensor outputs prior to digital processing. The processor board provides digital signal processing of the signals from the flow sensor interfaces and calculates mass flow, volumetric flow, density, and temperature. The processor board controls the LCD display and monitors the keypad, and also monitors or controls the other 10 signals that pass through the I/O part.
The processor board outputs a frequency that is proportional to the flow rate : 0 to 10 kHz, 24VDC square wave signal. The processor board outputs a 4 to 20mA signal that is proportional to the value of the selected variable. The processor board can also make communication according to the agreement by the serial interface.
Specifications
Materials |
Flow Tube, SS316L ; Housing, SS304 |
|---|---|
Meter Sizes |
DN3-DN200 |
Fluid Temperture |
-50℃~200℃ |
Pressure Rating |
4.0MPA, 10.0MPA, 16.0MPA, 25.0MPA, 42.0MPA, others on request |
Ambient Temperature |
Primary : -40℃~65℃ ; Converter : -15℃~55℃ |
Accuracy |
0.15%, 0.2%, 0.5% |
Flow Ranges Ratio |
1 : 20 |
Process Connections |
Flanges, Screw thread |
Supply Power |
AC 85~265V or DC 18~36V |
Power |
≤10W |
Output Signal |
4~20mA |
Frequency Output |
0~10KHz |
Communications |
RS485, Modbus |
Protection Class |
IP67 |
Explosions Proof Design |
Exd[ib]ⅡCT4 |
Measuring Ranges, Flow
Meter Size(mm) |
Ranges (kg/min) |
Zero drift (kg/min) |
|---|---|---|
|
3 6 10 |
0~3 0~15 0~30 |
0.0011 0.004 0.006 |
|
20 25 32 |
0~70 0~200 0~360 |
0.014 0.04 0.07 |
|
40 50 80 |
0~500 0~1200 0~3000 |
0.10 0.24 0.52 |
|
100 150 200 |
0~5000 0~11000 0~18000 |
0.71 1.21 1.9 |
Dimensions
Sensor :
PRESSURE Rating |
Diameter |
A |
B |
C |
D |
Process Connections |
Weight kg |
|---|---|---|---|---|---|---|---|
4MPa |
3 |
190 |
180 |
50 |
M14×1.5 |
3 |
|
6 |
222 |
165 |
50 |
M22×1.5 |
3.7 |
||
10 |
305 |
200 |
60 |
M22×1.5 |
5.5 |
||
15 |
326 |
370 |
300 |
84 |
Flange Connection Flange standards : JB/T82 1-94 |
14 |
|
25 |
446 |
440 |
385 |
104 |
21 |
||
32 |
460 |
490 |
420 |
94 |
28 |
||
40 |
566 |
562 |
444 |
124 |
36 |
||
50 |
646 |
760 |
525 |
144 |
60 |
||
80 |
776 |
943 |
592 |
206 |
116 |
||
100 |
864 |
1350 |
748 |
276 |
175 |
||
150 |
1092 |
1830 |
1100 |
412 |
360 |
||
200 |
1320 |
2136 |
1214 |
530 |
520 |
||
25MPa |
10 |
305 |
200 |
60 |
M22×1.5 |
6 |
|
16MPa |
25 |
480 |
440 |
385 |
104 |
Flange Connection Flange standards : JB/T82 1-94 |
22 |
10MPa |
40 |
610 |
562 |
444 |
124 |
37 |
※ Please contact our Sales Department for detailed specifications.