Coriolis – Alia ACF6000 Series
ACF6000 Series uses the Coriolis effect as a technique for liquid mass flow measurement. The ACF6000 can measure most of the liquids; the infrared light sensor makes it easy for you to set parameters & change the display data. The Double-C tube & Double-D Tube make it possible for the meter to be used in most liquid applications.
Features
- Can be programmed by infrared light sensor without opening cover
- High turndown ratio of flow rate
- It comes any flanges such as ANSI, DIN, JIS... etc
- Excellent for high pressure application
- Simple for installation, commission and maintenance
- Self-diagnostic capabilities, cable faults, pipe vibration
- High accuracy of +/-0.2% of reading (or +/-0.1% of reading)
- With forward / reverse flow rate measurement function
Specification
| Sensor Type: | Display: |
| C tube (10-40mm) / U tube (50-150mm) | 2 lines LCD with illumination |
| Size: | Flow Rate Unit |
| 10mm ~ 200 mm (3/8" ~ 8") | g/s, Kg/min, kg/Hr, T/Hr, 6 Digit |
| Flow Range: | Density Unit |
| 0 - 1000 Kg/Hr ~ 0 - 1106000 Kg/Hr | Kg/m3, g/cc, 6 Digit |
| Accuracy: | Totalizer Unit |
| +/-0.2% +/-ZS of reading (Standard) | g, Kg, Ton, L, M3, 7 Digits |
| +/-0.1% +/-ZS of reading (Optional) | Temperature |
| Repeatability: | oC, oF, 4 Digits |
| +/-0.03% +/-ZS of reading | Keypad: |
| Density Range: | Infrared light Sensor, |
| 200 - 2300 Kg/M3 (0.2 - 2.3 g/cm3) | can be programmed without |
| Accuracy | Opening the cover |
| +/-0.002 g/cm3 | Turndown Ratio: |
| Temperature Range: | 20 : 1 |
| -40 oC ~ +125 oC (Standard) | Damping: |
| -40 oC ~ +250 oC (Optional, Separate Only) | 0.01 To 1.0 Seconds |
| Material: | Low Flow Cutoff: |
| Wetted Parts | 0.0% ~ 9.0% |
| Stainless Steel 316L | Communication: |
| Flange | RS485 (Modbus Protocol) (Standard) |
| Stainless Steel 316L | Hart Signal (Optional) |
| Sensor Housing | Current Output: |
| Stainless Steel 304 | 4-20 mA (Isolated) |
| Junction Box | Load |
| Aluminum Alloy (Epoxy Paint) | Max. 750 |
| Process Connection: | Output Unit |
| Flange | Mass / Volume / Density / Temperature |
| Flange Type: | Pulse (Alarm) Output: |
| JIS 10K / JIS 20K / JIS 40K | Open Collector |
| ANSI 150# / ANSI 300# / ANSI 600# | Rating |
| DIN PN 10 / PN 16 / PN25 / PN 40 | 3-30Vdc, 50mA Max. |
| Protection Class: | Power Supply: |
| IP 67 | 90-260 VAC, 50/60 Hz or 24 VDC +/-10% |
| Explosion Proof Exde (ib) IIC T6 (Optional) | Power Consumption: |
| Installation: | 30 - 40 W (Depend on sensor size) |
| Compact or Separate | Cable Entry: |
| Signal Cable Length: | Sensor to Converter- 3/4" G |
| 10M - 100M | Signal output / Power supply- M20 |
| Ambient Temperature: | |
| -40 oC to +60 oC | |
| Max. Pressure: | |
| 63 Kg/cm2 |
Catalogues
Coriolis – Alia ACF6000 Series
Coriolis – Alia ACF6000 Series: overview and buying guide
The Coriolis – Alia ACF6000 Series (model ACF6000 Series) is made by M&C ENGINEERING and listed in our test · measurement range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.
Frequently asked questions
How much does the Coriolis – Alia ACF6000 Series cost?
Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.
Can you ship the Coriolis – Alia ACF6000 Series to my country?
Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.
Is this a genuine M&C ENGINEERING product?
We purchase directly from M&C ENGINEERING or its authorised channels and confirm the model and specifications with the manufacturer before ordering.
What is the minimum order quantity?
For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.
ACF6000 Series uses the Coriolis effect as a technique for liquid mass flow measurement. The ACF6000 can measure most of the liquids; the infrared light sensor makes it easy for you to set parameters & change the display data. The Double-C tube & Double-D Tube make it possible for the meter to be used in most liquid applications.
Features
- Can be programmed by infrared light sensor without opening cover
- High turndown ratio of flow rate
- It comes any flanges such as ANSI, DIN, JIS... etc
- Excellent for high pressure application
- Simple for installation, commission and maintenance
- Self-diagnostic capabilities, cable faults, pipe vibration
- High accuracy of +/-0.2% of reading (or +/-0.1% of reading)
- With forward / reverse flow rate measurement function
Specification
| Sensor Type: | Display: |
| C tube (10-40mm) / U tube (50-150mm) | 2 lines LCD with illumination |
| Size: | Flow Rate Unit |
| 10mm ~ 200 mm (3/8" ~ 8") | g/s, Kg/min, kg/Hr, T/Hr, 6 Digit |
| Flow Range: | Density Unit |
| 0 - 1000 Kg/Hr ~ 0 - 1106000 Kg/Hr | Kg/m3, g/cc, 6 Digit |
| Accuracy: | Totalizer Unit |
| +/-0.2% +/-ZS of reading (Standard) | g, Kg, Ton, L, M3, 7 Digits |
| +/-0.1% +/-ZS of reading (Optional) | Temperature |
| Repeatability: | oC, oF, 4 Digits |
| +/-0.03% +/-ZS of reading | Keypad: |
| Density Range: | Infrared light Sensor, |
| 200 - 2300 Kg/M3 (0.2 - 2.3 g/cm3) | can be programmed without |
| Accuracy | Opening the cover |
| +/-0.002 g/cm3 | Turndown Ratio: |
| Temperature Range: | 20 : 1 |
| -40 oC ~ +125 oC (Standard) | Damping: |
| -40 oC ~ +250 oC (Optional, Separate Only) | 0.01 To 1.0 Seconds |
| Material: | Low Flow Cutoff: |
| Wetted Parts | 0.0% ~ 9.0% |
| Stainless Steel 316L | Communication: |
| Flange | RS485 (Modbus Protocol) (Standard) |
| Stainless Steel 316L | Hart Signal (Optional) |
| Sensor Housing | Current Output: |
| Stainless Steel 304 | 4-20 mA (Isolated) |
| Junction Box | Load |
| Aluminum Alloy (Epoxy Paint) | Max. 750 |
| Process Connection: | Output Unit |
| Flange | Mass / Volume / Density / Temperature |
| Flange Type: | Pulse (Alarm) Output: |
| JIS 10K / JIS 20K / JIS 40K | Open Collector |
| ANSI 150# / ANSI 300# / ANSI 600# | Rating |
| DIN PN 10 / PN 16 / PN25 / PN 40 | 3-30Vdc, 50mA Max. |
| Protection Class: | Power Supply: |
| IP 67 | 90-260 VAC, 50/60 Hz or 24 VDC +/-10% |
| Explosion Proof Exde (ib) IIC T6 (Optional) | Power Consumption: |
| Installation: | 30 - 40 W (Depend on sensor size) |
| Compact or Separate | Cable Entry: |
| Signal Cable Length: | Sensor to Converter- 3/4" G |
| 10M - 100M | Signal output / Power supply- M20 |
| Ambient Temperature: | |
| -40 oC to +60 oC | |
| Max. Pressure: | |
| 63 Kg/cm2 |