Condensing Boiler SCB
· Economic:
① Official certificate/certification of high effectiveness (Low calorific power standard 101%)
② Epoch-making fuel cost curtailment (exhaust gas waste heat temperature 65°C or so)
③ Advancement in quality and productivity by the rich stock of steam.
④ Life-time existence with strong durability by the special combustion structure.
· Convenience:
① Automatic controlled system that all functions are achieved perfectly by single-touch
② Easy manage and repair by the manual control system
③ High safety by the double or triple safety control system
④ Great convenience to check the status of equipment by built in type of additional equipment which related to automation./automated equipment
· Place to use:
Product that should use certainly in large size industry that use from gas(LNG).
Dye works / Dumpling factory / General Food factory / Heating and hot-water supply / Sauna / Chemical Plant / Non-rigid type food factory / Other large size industry
| Division / Type | SCB-100 | SCB-150 | SCB-200 | SCB-250 | SCB-300 | SCB-400 | SCB-500 | SCB-600 | SCB-700 | SCB-800 | SCB-1000 | ||
| Proper form of Evaporation | kg/h | 1,000 | 1,500 | 2,000 | 2,500 | 3,000 | 4,000 | 5,000 | 6,000 | 7,000 | 8,000 | 10,000 | |
| Max. Working Pressure | kg/㎠ | 10{1.0MPa} | |||||||||||
| Efficiency | % | More than 99% | |||||||||||
| Electric Tranmission Area | ㎡ | 15 | 25.2 | 30.3 | 37 | 44.4 | 58 | 74 | 88 | 99 | 114 | 143 | |
| Weight | Ton | 4.0 | 4.8 | 5.1 | 5.8 | 6.5 | 7.2 | 8.6 | 10.6 | 13.3 | 14.5 | 17.4 | |
| Titration | ℓ | 1,650 | 1,920 | 2,200 | 2,800 | 3,082 | 4,600 | 5,800 | 6,950 | 9,100 | 13,300 | 14,700 | |
| Fuel Consumption | LNG | N㎥ | 63.9 | 95.8 | 127.8 | 159.7 | 191.7 | 255.8 | 319.4 | 383.3 | 447.2 | 511.1 | 638.9 |
| LPG(Propane) | N㎥ | 28.3 | 42.4 | 56.5 | 70.7 | 84.8 | 113 | 141.3 | 169.6 | 197.8 | 226.1 | 282.6 | |
| Capacitance of Electric | kW | 5.9 | 7.7 | 9.7 | 14 | 14 | 18.7 | 18.7 | 19 | 24.5 | 27.5 | 37.5 | |
| Joint Valve | Main Steam Valve | A | 50 | 65 | 80 | 80 | 80 | 100 | 125 | 125 | 150 | 150 | 200 |
| Progression Valve | 25 | 25 | 40 | 40 | 40 | 40 | 40 | 40 | 50 | 50 | 50 | ||
| Drainage Valve | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 50 | 50 | 50 | ||
| Safety Valve | 25 | 32 | 40 | 40 | 40 | 25,40 | 40×2 | 40×2 | 40,50 | 50×2 | 50×2 | ||
| Fuel Gas | 25 | 40 | 40 | 50 | 50 | 50 | 50 | 65 | 65 | 80 | 80 | ||
| Chimney | ømm | 300 | 350 | 400 | 500 | 550 | 600 | 650 | 700 | 750 | 800 | 900 | |
| Minimum Dimension | Width | mm | 1,670 | 1,720 | 1,800 | 1,890 | 2,050 | 2,290 | 2,380 | 2,634 | 2,702 | 2,862 | 3,346 |
| Length | 3,160 | 3,550 | 3,770 | 3,800 | 4,100 | 4,500 | 4,810 | 5,162 | 5,467 | 5,772 | 6,076 | ||
| Height | 2,120 | 2,280 | 2,510 | 2,590 | 2,700 | 2,980 | 3,120 | 3,632 | 3,700 | 3,860 | 4,344 | ||
| Maximum Dimension | Width | mm | 2,180 | 2,200 | 2,290 | 2,460 | 2,550 | 2,660 | 2,758 | 3,012 | 3,080 | 3,240 | 3,724 |
| Length | 3,880 | 4,030 | 4,128 | 4,280 | 4,380 | 4,480 | 4,940 | 5,692 | 5,897 | 6,402 | 6,706 | ||
| Height | 2,690 | 2,870 | 3,000 | 3,020 | 3,070 | 3,096 | 3,178 | 3,432 | 3,950 | 4,010 | 4,144 | ||
※ Low calorific power fuel
① LNG:41.45 MJ/N㎥{9,900kcal/N㎥}, ② LPG{Propane}:93.7 MJ/N㎥{22,380kcal/N㎥}
※ The specification list are subject to change without prior notice to improve the performance and technology development.
Detailed specification sheets are shown in the product images.
Condensing Boiler SCB
Condensing Boiler SCB: overview and buying guide
The Condensing Boiler SCB (model SCB) is made by Samho Boiler and listed in our hvac range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.
Frequently asked questions
How much does the Condensing Boiler SCB cost?
Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.
Can you ship the Condensing Boiler SCB to my country?
Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.
Is this a genuine Samho Boiler product?
We purchase directly from Samho Boiler or its authorised channels and confirm the model and specifications with the manufacturer before ordering.
What is the minimum order quantity?
For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.
· Economic:
① Official certificate/certification of high effectiveness (Low calorific power standard 101%)
② Epoch-making fuel cost curtailment (exhaust gas waste heat temperature 65°C or so)
③ Advancement in quality and productivity by the rich stock of steam.
④ Life-time existence with strong durability by the special combustion structure.
· Convenience:
① Automatic controlled system that all functions are achieved perfectly by single-touch
② Easy manage and repair by the manual control system
③ High safety by the double or triple safety control system
④ Great convenience to check the status of equipment by built in type of additional equipment which related to automation./automated equipment
· Place to use:
Product that should use certainly in large size industry that use from gas(LNG).
Dye works / Dumpling factory / General Food factory / Heating and hot-water supply / Sauna / Chemical Plant / Non-rigid type food factory / Other large size industry
| Division / Type | SCB-100 | SCB-150 | SCB-200 | SCB-250 | SCB-300 | SCB-400 | SCB-500 | SCB-600 | SCB-700 | SCB-800 | SCB-1000 | ||
| Proper form of Evaporation | kg/h | 1,000 | 1,500 | 2,000 | 2,500 | 3,000 | 4,000 | 5,000 | 6,000 | 7,000 | 8,000 | 10,000 | |
| Max. Working Pressure | kg/㎠ | 10{1.0MPa} | |||||||||||
| Efficiency | % | More than 99% | |||||||||||
| Electric Tranmission Area | ㎡ | 15 | 25.2 | 30.3 | 37 | 44.4 | 58 | 74 | 88 | 99 | 114 | 143 | |
| Weight | Ton | 4.0 | 4.8 | 5.1 | 5.8 | 6.5 | 7.2 | 8.6 | 10.6 | 13.3 | 14.5 | 17.4 | |
| Titration | ℓ | 1,650 | 1,920 | 2,200 | 2,800 | 3,082 | 4,600 | 5,800 | 6,950 | 9,100 | 13,300 | 14,700 | |
| Fuel Consumption | LNG | N㎥ | 63.9 | 95.8 | 127.8 | 159.7 | 191.7 | 255.8 | 319.4 | 383.3 | 447.2 | 511.1 | 638.9 |
| LPG(Propane) | N㎥ | 28.3 | 42.4 | 56.5 | 70.7 | 84.8 | 113 | 141.3 | 169.6 | 197.8 | 226.1 | 282.6 | |
| Capacitance of Electric | kW | 5.9 | 7.7 | 9.7 | 14 | 14 | 18.7 | 18.7 | 19 | 24.5 | 27.5 | 37.5 | |
| Joint Valve | Main Steam Valve | A | 50 | 65 | 80 | 80 | 80 | 100 | 125 | 125 | 150 | 150 | 200 |
| Progression Valve | 25 | 25 | 40 | 40 | 40 | 40 | 40 | 40 | 50 | 50 | 50 | ||
| Drainage Valve | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 50 | 50 | 50 | ||
| Safety Valve | 25 | 32 | 40 | 40 | 40 | 25,40 | 40×2 | 40×2 | 40,50 | 50×2 | 50×2 | ||
| Fuel Gas | 25 | 40 | 40 | 50 | 50 | 50 | 50 | 65 | 65 | 80 | 80 | ||
| Chimney | ømm | 300 | 350 | 400 | 500 | 550 | 600 | 650 | 700 | 750 | 800 | 900 | |
| Minimum Dimension | Width | mm | 1,670 | 1,720 | 1,800 | 1,890 | 2,050 | 2,290 | 2,380 | 2,634 | 2,702 | 2,862 | 3,346 |
| Length | 3,160 | 3,550 | 3,770 | 3,800 | 4,100 | 4,500 | 4,810 | 5,162 | 5,467 | 5,772 | 6,076 | ||
| Height | 2,120 | 2,280 | 2,510 | 2,590 | 2,700 | 2,980 | 3,120 | 3,632 | 3,700 | 3,860 | 4,344 | ||
| Maximum Dimension | Width | mm | 2,180 | 2,200 | 2,290 | 2,460 | 2,550 | 2,660 | 2,758 | 3,012 | 3,080 | 3,240 | 3,724 |
| Length | 3,880 | 4,030 | 4,128 | 4,280 | 4,380 | 4,480 | 4,940 | 5,692 | 5,897 | 6,402 | 6,706 | ||
| Height | 2,690 | 2,870 | 3,000 | 3,020 | 3,070 | 3,096 | 3,178 | 3,432 | 3,950 | 4,010 | 4,144 | ||
※ Low calorific power fuel
① LNG:41.45 MJ/N㎥{9,900kcal/N㎥}, ② LPG{Propane}:93.7 MJ/N㎥{22,380kcal/N㎥}
※ The specification list are subject to change without prior notice to improve the performance and technology development.
Detailed specification sheets are shown in the product images.