Compact VUV CCD Spectrometer VU90
Overview
Most Compact Vacuum UV Back-Illuminated CCD Spectrometer (VUV-FUV)
Horiba has developed a compact size Vacuum Ultraviolet (VUV) Spectrometer with a dedicated CCD Camera Syncerity-VUV, all manufactured in its NJ facility. This unique system features a special CCD sensor with high sensitivity in the far-UV wavelength range with capability to measure from 115 nm with a resolution better than 0.5 nm under vacuum or high purity nitrogen. The system’s internal optical cavity can be black coated for ultimate suppression of stray light.
For OEM VUV Industrial Applications
ㆍ VUV Emission & Fluorescence
ㆍ VUV Transmission & Reflectance
ㆍ GCVUV: Alternative to Conventional Gas Chromatography
ㆍ Examples :
- Metrology
- Photolithography
- Petrology
- Environmental Monitoring
- Flavors & Fragrances
- Food & Beverage Safety
Features
ㆍ First portable and most affordable VUV spectrometer
ㆍ Smallest VUV system footprint on the market
ㆍ Ultra high throughput combined with unmatched low stray light performance
ㆍ High resolution of 0.5 nm Selectable resolution and throughput
ㆍ Deep-cooled CCD with high quantum efficiency
ㆍ Extendable wavelength coverage from Far UV to UV-VIS-NIR
CCD Quantum Efficiency
UV hardened sensor provides increased lifetime, however no warranty is provided on any sensor exposed to VUV
Stray Light Comparison
Stray light comparison between uncoated and coated cavity (Super Black) measured by far field illumination using tungsten lamp – zero order
Spectrum of Deuterium
Spectrum of Deuterium lamp shows enhanced sensitivity starting from 113 nm with 22 µm slit (0.45 nm resolution)
VUV System Slit Interchangeability Test
VUV system slit interchangeability test with 40 µm pinhole and 22 µm slit
OEM Spectrometer Selection Guide
Specifications
| General Spectrometer Specifications | |
|---|---|
| Spectral Coverage | 115 - 230 nm Full coverage on CCD: 115 - 320 nm (No order sorting filter available) |
| Spectral Resolution | 0.5 nm with 22 μm pinhole, 0.75 nm with 40 μm pinhole |
| Spectral Dipersion | 12 nm/mm; 0.17 nm/pixel |
| Focal Length | 90 mm |
| VUV Optics | MgF2 coated grating and mirror |
| Vacuum or Nitrogen Purged Mode | ~ 10-6 Torr with turbomolecular pump. Helium leak test performed at factory. N2 high purity nitrogen constant purge required |
| Options | Selection of different heights of VUV CCDs Kinematic mounts to interchange Pinholes (or Slits) Bare metal finish is standard: Super black coating reduces stray light |
| F/# | ~ F/10 |
| Software | LabVIEW Acquisition sortware for initial evaluation (DLLs provided for software integration) |
| Vacuum Camera Specifications (Syncerity® VUV 2048 pixel BI Sensor)* | ||
|---|---|---|
| Quantum efficiency at 20°C (see plots below) | Standard | Special |
| CCD Sensor Format | 2048 x 70 | Optional increased heights available |
| CCD Pixel Size | 14 x14 μm | |
| CCD Height | 1 mm | |
| CCD QE | 3 options - refer to graphs below | |
| Camera Window | 2 options - no window for lowest VUV response or MgF2 window | |
| Deep Thermoelectric Cooling | -45°C under vacuum (10-6 mbar) with +25°C ambient or -25°C under N2 purging | |
| Single Pixel Well Capacity | 50,000 e¯/pixel (minimum); 60,000 e¯/pixel (typical) | |
| Serial Register Full Well Capacity | 250,000 e¯/pixel (minimum); 500,000 e¯/pixel (typical output register saturation) | |
| Scan Rates | 45 kHz and 500 kHz | |
| Readout Noise (at 45 kHz and at –45°C) | 10 e¯ (typical) to 14 e¯ (maximum) | |
| Readout Noise (at 500 kHz and at –45°C) | 20 e¯ (typical) to 25 e¯ (maximum) | |
| Maximum Spectral Rate | 20 Hz at 45 kHz scan rate; 189 Hz at 500 kHz scan rate | |
| Digitization | 16-bit ADC | |
| Dynamic Range (typical for single pixel) | 55,500:1 | |
| Non-linearity (measured on each camera) | <0.15% (typical) at 45 kHz (0.4% maximum) | |
| <0.20% (typical) at 500 kHz (1% maximum) | ||
| Dark Current at –45°C Note: Pixel size = 14 μm | 0.1 e¯ /pixel/s (typical) | |
| Software-adjustable Gains | 2, 4, and 10 e¯ /count at –45°C | |
| Environmental Conditions | Operating temperature 15°C to 40°C ambient | |
| Relative humidity <70% (non-condensing) | ||
| Storage temperature -25°C to 45°C | ||
| Power Requirements AC/DC Power Supply (provided) | 90-264 VAC, 47–63 Hz | |
*Specifications, form factor, and spectrometer cover subject to change without notice. No LabVIEW™ license is needed to run our acquisition software.
CCD Quantum Efficiency
UV hardened sensor provides increased lifetime, however no warranty is provided on any sensor exposed to VUV
Mechanical Drawings
Detailed specification sheets are shown in the product images.
Catalogues
Compact VUV CCD Spectrometer VU90
Compact VUV CCD Spectrometer VU90: overview and buying guide
The Compact VUV CCD Spectrometer VU90 (model VU90) is made by HORIBA and listed in our test · measurement range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.
Frequently asked questions
How much does the Compact VUV CCD Spectrometer VU90 cost?
Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.
Can you ship the Compact VUV CCD Spectrometer VU90 to my country?
Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.
Is this a genuine HORIBA product?
We purchase directly from HORIBA or its authorised channels and confirm the model and specifications with the manufacturer before ordering.
What is the minimum order quantity?
For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.
Overview
Most Compact Vacuum UV Back-Illuminated CCD Spectrometer (VUV-FUV)
Horiba has developed a compact size Vacuum Ultraviolet (VUV) Spectrometer with a dedicated CCD Camera Syncerity-VUV, all manufactured in its NJ facility. This unique system features a special CCD sensor with high sensitivity in the far-UV wavelength range with capability to measure from 115 nm with a resolution better than 0.5 nm under vacuum or high purity nitrogen. The system’s internal optical cavity can be black coated for ultimate suppression of stray light.
For OEM VUV Industrial Applications
ㆍ VUV Emission & Fluorescence
ㆍ VUV Transmission & Reflectance
ㆍ GCVUV: Alternative to Conventional Gas Chromatography
ㆍ Examples :
- Metrology
- Photolithography
- Petrology
- Environmental Monitoring
- Flavors & Fragrances
- Food & Beverage Safety
Features
ㆍ First portable and most affordable VUV spectrometer
ㆍ Smallest VUV system footprint on the market
ㆍ Ultra high throughput combined with unmatched low stray light performance
ㆍ High resolution of 0.5 nm Selectable resolution and throughput
ㆍ Deep-cooled CCD with high quantum efficiency
ㆍ Extendable wavelength coverage from Far UV to UV-VIS-NIR
CCD Quantum Efficiency
UV hardened sensor provides increased lifetime, however no warranty is provided on any sensor exposed to VUV
Stray Light Comparison
Stray light comparison between uncoated and coated cavity (Super Black) measured by far field illumination using tungsten lamp – zero order
Spectrum of Deuterium
Spectrum of Deuterium lamp shows enhanced sensitivity starting from 113 nm with 22 µm slit (0.45 nm resolution)
VUV System Slit Interchangeability Test
VUV system slit interchangeability test with 40 µm pinhole and 22 µm slit
OEM Spectrometer Selection Guide
Specifications
| General Spectrometer Specifications | |
|---|---|
| Spectral Coverage | 115 - 230 nm Full coverage on CCD: 115 - 320 nm (No order sorting filter available) |
| Spectral Resolution | 0.5 nm with 22 μm pinhole, 0.75 nm with 40 μm pinhole |
| Spectral Dipersion | 12 nm/mm; 0.17 nm/pixel |
| Focal Length | 90 mm |
| VUV Optics | MgF2 coated grating and mirror |
| Vacuum or Nitrogen Purged Mode | ~ 10-6 Torr with turbomolecular pump. Helium leak test performed at factory. N2 high purity nitrogen constant purge required |
| Options | Selection of different heights of VUV CCDs Kinematic mounts to interchange Pinholes (or Slits) Bare metal finish is standard: Super black coating reduces stray light |
| F/# | ~ F/10 |
| Software | LabVIEW Acquisition sortware for initial evaluation (DLLs provided for software integration) |
| Vacuum Camera Specifications (Syncerity® VUV 2048 pixel BI Sensor)* | ||
|---|---|---|
| Quantum efficiency at 20°C (see plots below) | Standard | Special |
| CCD Sensor Format | 2048 x 70 | Optional increased heights available |
| CCD Pixel Size | 14 x14 μm | |
| CCD Height | 1 mm | |
| CCD QE | 3 options - refer to graphs below | |
| Camera Window | 2 options - no window for lowest VUV response or MgF2 window | |
| Deep Thermoelectric Cooling | -45°C under vacuum (10-6 mbar) with +25°C ambient or -25°C under N2 purging | |
| Single Pixel Well Capacity | 50,000 e¯/pixel (minimum); 60,000 e¯/pixel (typical) | |
| Serial Register Full Well Capacity | 250,000 e¯/pixel (minimum); 500,000 e¯/pixel (typical output register saturation) | |
| Scan Rates | 45 kHz and 500 kHz | |
| Readout Noise (at 45 kHz and at –45°C) | 10 e¯ (typical) to 14 e¯ (maximum) | |
| Readout Noise (at 500 kHz and at –45°C) | 20 e¯ (typical) to 25 e¯ (maximum) | |
| Maximum Spectral Rate | 20 Hz at 45 kHz scan rate; 189 Hz at 500 kHz scan rate | |
| Digitization | 16-bit ADC | |
| Dynamic Range (typical for single pixel) | 55,500:1 | |
| Non-linearity (measured on each camera) | <0.15% (typical) at 45 kHz (0.4% maximum) | |
| <0.20% (typical) at 500 kHz (1% maximum) | ||
| Dark Current at –45°C Note: Pixel size = 14 μm | 0.1 e¯ /pixel/s (typical) | |
| Software-adjustable Gains | 2, 4, and 10 e¯ /count at –45°C | |
| Environmental Conditions | Operating temperature 15°C to 40°C ambient | |
| Relative humidity <70% (non-condensing) | ||
| Storage temperature -25°C to 45°C | ||
| Power Requirements AC/DC Power Supply (provided) | 90-264 VAC, 47–63 Hz | |
*Specifications, form factor, and spectrometer cover subject to change without notice. No LabVIEW™ license is needed to run our acquisition software.
CCD Quantum Efficiency
UV hardened sensor provides increased lifetime, however no warranty is provided on any sensor exposed to VUV
Mechanical Drawings
Detailed specification sheets are shown in the product images.