Cold Silver Galvanizing YECOA YL-501K
Packaging Unit : Aerosol 420㎖/Can, 20cans/Box
Product Information
YECOA YL-501K is a silver anti-rust coating agent (hot-dip galvanizing repair agent)
ㆍKorea Register Type Approved Product
ㆍExcellent durability and heat resistance (heat resistance 500℃)
ㆍExcellent durability with zinc plating that has excellent heat resistance and chemical resistance in the coated area
ㆍHigh adhesion special binder plating agent for ships, vehicles, bridges, power generation, construction, etc.
ㆍExcellent anti-rust performance, especially in harsh environments with high salt content or prone to corrosion, or on already corroded metal surfaces.
Applications
1. Rust prevention for steel materials and structures
2. Repair and substitute for zinc plating, repair and finish coating for damaged plated parts
3. Bridges, steel towers, steel, automobiles, railway vehicles, gas pipelines, pipes, etc.
How to Use
1. Arrange the parts to be used in the working order.
2. Please separate general parts attached to the equipment in advance.
3. To remove foreign substances from the coating surface, spray YL-116 cleaner with a compressor air to improve the performance of the coating surface.
4. Spray the YL-501K product evenly from about 20cm away from the surface to be coated.
5. Coat other necessary parts in the same way.
6. Depending on the work situation, wipe and finish with a cloth, brush, etc.
7. Please be sure to familiarize yourself with and use the Material Safety Data Sheet (MSDS) prepared in accordance with Article 41 of the Industrial Safety and Health Act and Ministry of Employment and Labor Notice No. 2013-37 (Standards for preparing/providing Material Safety Data Sheets).
Precautions
1. Do not use for purposes other than intended.
2. Keep out of reach of children.
3. If the contents come into contact with eyes or skin, wash with clean water and consult a doctor if there are any abnormalities.
4. Do not spray directly on food or face, and do not inhale or ingest.
5. As it is a flammable product using high-pressure gas, it is dangerous, so please observe the following precautions.
① Do not use towards flames, and do not use near open flames such as stoves or furnaces.
② Do not use indoors where open flames are being used.
③ Do not store in places with temperatures above 40℃.
④ After use in a confined indoor space, be sure to ventilate.
⑤ Dispose of after use to ensure no residual gas, and never dispose of in fire.
⑥ Do not store in a confined space.
⑦ Spray performance may be poor at temperatures below 5℃.
Cold Silver Galvanizing YECOA YL-501K
Cold Silver Galvanizing YECOA YL-501K: overview and buying guide
The Cold Silver Galvanizing YECOA YL-501K (model YECOA YL-501K) is made by YOUNG IL TOTAL AEROSOL and listed in our chemical range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.
Frequently asked questions
How much does the Cold Silver Galvanizing YECOA YL-501K cost?
Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.
Can you ship the Cold Silver Galvanizing YECOA YL-501K to my country?
Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.
Is this a genuine YOUNG IL TOTAL AEROSOL product?
We purchase directly from YOUNG IL TOTAL AEROSOL or its authorised channels and confirm the model and specifications with the manufacturer before ordering.
What is the minimum order quantity?
For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.
Packaging Unit : Aerosol 420㎖/Can, 20cans/Box
Product Information
YECOA YL-501K is a silver anti-rust coating agent (hot-dip galvanizing repair agent)
ㆍKorea Register Type Approved Product
ㆍExcellent durability and heat resistance (heat resistance 500℃)
ㆍExcellent durability with zinc plating that has excellent heat resistance and chemical resistance in the coated area
ㆍHigh adhesion special binder plating agent for ships, vehicles, bridges, power generation, construction, etc.
ㆍExcellent anti-rust performance, especially in harsh environments with high salt content or prone to corrosion, or on already corroded metal surfaces.
Applications
1. Rust prevention for steel materials and structures
2. Repair and substitute for zinc plating, repair and finish coating for damaged plated parts
3. Bridges, steel towers, steel, automobiles, railway vehicles, gas pipelines, pipes, etc.
How to Use
1. Arrange the parts to be used in the working order.
2. Please separate general parts attached to the equipment in advance.
3. To remove foreign substances from the coating surface, spray YL-116 cleaner with a compressor air to improve the performance of the coating surface.
4. Spray the YL-501K product evenly from about 20cm away from the surface to be coated.
5. Coat other necessary parts in the same way.
6. Depending on the work situation, wipe and finish with a cloth, brush, etc.
7. Please be sure to familiarize yourself with and use the Material Safety Data Sheet (MSDS) prepared in accordance with Article 41 of the Industrial Safety and Health Act and Ministry of Employment and Labor Notice No. 2013-37 (Standards for preparing/providing Material Safety Data Sheets).
Precautions
1. Do not use for purposes other than intended.
2. Keep out of reach of children.
3. If the contents come into contact with eyes or skin, wash with clean water and consult a doctor if there are any abnormalities.
4. Do not spray directly on food or face, and do not inhale or ingest.
5. As it is a flammable product using high-pressure gas, it is dangerous, so please observe the following precautions.
① Do not use towards flames, and do not use near open flames such as stoves or furnaces.
② Do not use indoors where open flames are being used.
③ Do not store in places with temperatures above 40℃.
④ After use in a confined indoor space, be sure to ventilate.
⑤ Dispose of after use to ensure no residual gas, and never dispose of in fire.
⑥ Do not store in a confined space.
⑦ Spray performance may be poor at temperatures below 5℃.
