{"product_id":"capacitance-type-level-switch-131493","title":"Capacitance Type Level Switch SCAP Series","description":"\u003ch3\u003eCapacitance Type Level Switch\u003c\/h3\u003e\u003ctable class=\"pem-spec\"\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ctable class=\"pem-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\"\u003e\u003cp\u003eFormat and Model\u003c\/p\u003e\u003c\/th\u003e\n\u003cth colspan=\"1\" rowspan=\"1\"\u003e\u003cp\u003eSCAP\u003c\/p\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\"\u003e\u003cp\u003eOperating principle\u003c\/p\u003e\u003c\/th\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003cp\u003eUtilizing the principle that capacitance is generated between conductors, the capacitance C changes due to the difference in relative permittivity (εr) between when an air layer exists between the sensor probe and a conductor, such as a tank, and when a measuring medium is present.\u003cbr\u003eA capacitive level switch detects this change in capacitance value, and a signal is transmitted to output a contact, allowing the level (liquid level) to be controlled.\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\"\u003e\u003cp\u003erange\u003c\/p\u003e\u003c\/th\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003cp\u003eㆍ250~4000 mm(Max)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\"\u003e\u003cp\u003etemperature\u003c\/p\u003e\u003c\/th\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003cp\u003eㆍ -20~230 ℃(Max)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\"\u003e\u003cp\u003eenter\u003c\/p\u003e\u003c\/th\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003cp\u003eㆍATM~10kgf\/㎠(Max)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\"\u003e\u003cp\u003echaracteristic\u003c\/p\u003e\u003c\/th\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003cp\u003eㆍ Precise setting (calibration) is possible without filling the sample.\u003cbr\u003eㆍ H\/L Alarm (Fail-safe) setting is available\u003cbr\u003e. Capable of measuring minute capacitance values ​​(detecting changes as small as 1pF)\u003cbr\u003e. Probe length can be adjusted on-site (SCAP-4).\u003cbr\u003eㆍ Used for measuring various liquids, powders, granules, solids, interfaces between two different liquids, steel, coal, food, pharmaceuticals, petrochemicals, chemicals, and precipitates in liquids.\u003cbr\u003eㆍ The probe has a simple structure, making installation and maintenance easy and ensuring a long lifespan.\u003cbr\u003eㆍ Various probes are available for different applications, enabling level measurement under special conditions such as high temperature, low temperature, high pressure, vacuum, and corrosive substances.\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\"\u003e\u003cp\u003eoutput of power\u003c\/p\u003e\u003c\/th\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003cp\u003eㆍDPDT (5A, 250V AC, 5A 30V DC)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\"\u003e\u003cp\u003ePower specifications\u003c\/p\u003e\u003c\/th\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003cp\u003eㆍ110V\/220V AC ±10% 50\/60Hz\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\"\u003e\u003cp\u003eapply\u003c\/p\u003e\u003c\/th\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003cp\u003eㆍApplicable measurement media: Liquids, powders, lumps\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\"\u003e\u003cp\u003enote\u003c\/p\u003e\u003c\/th\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003cp\u003ePlease refer to the catalog for details and specifications.\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cem\u003eDetailed specification sheets are shown in the product images.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eCatalogues\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/premiumemart.com\/cdn\/shop\/files\/pem-f-a2d055d253bfdfcf.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCatalog-Seojin instech-Capacitance auto level switch (SCAP)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/premiumemart.com\/cdn\/shop\/files\/pem-f-5b63e8fb9dc2e201\" target=\"_blank\" rel=\"noopener\"\u003eDrawing-Seojin instech-Capacitance auto level switch (SCAP)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/premiumemart.com\/cdn\/shop\/files\/pem-f-2e887f78ccff428a.pdf\" target=\"_blank\" rel=\"noopener\"\u003e메뉴얼-서진인스텍-Capacitance auto level switch (SCAP)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/premiumemart.com\/cdn\/shop\/files\/pem-f-aa10551df599f85d.pdf\" target=\"_blank\" rel=\"noopener\"\u003eManual-Seojin instech-Capacitance auto level switch (SCAP)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SEOJIN INSTECH","offers":[{"title":"Default Title","offer_id":58446591689044,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1098\/4649\/5572\/files\/085610a8-81bf-4b16-92a1-2909e266f5b3.png?v=1795191283","url":"https:\/\/premiumemart.com\/products\/capacitance-type-level-switch-131493","provider":"Premium Emart","version":"1.0","type":"link"}