BP-2 (Progressive cavity pump controller)
BP-2 (Progressive cavity pump controller)
Main functions and benefits
The BP-2 Progressive Cavity Pump Controller is a high-performance BPP-Series controller designed to regulate the motor connected to the rotor, controlling motor speed up to 120 rpm. It supports both shot and suckback functions, ensuring accurate, repeatable, and precise fluid dispensing. With its real-time mode, the BP-2 offers ON/OFF control or time-setting control, providing versatile operation for a variety of precision fluid applications.
Key Features
Precise Motor Control for Fluid Dispensing: Regulates motor speed up to 120 rpm, ensuring consistent and accurate fluid flow for high-precision applications. Supports both shot and suckback functions for controlled fluid release and cut-off.
Real-Time Mode for Fluid Accuracy: Offers ON/OFF control or time-setting control for enhanced flexibility and precision in dispensing small amounts of fluid.
Smooth Fluid Dispensing: Minimizes tube wear and eliminates pulsation, delivering consistent and reliable fluid flow without disruptions, ensuring high dispensing accuracy in every cycle.
Advanced Liquid Control for Precision Dispensing: Equipped with liquid suction, forward/reverse rotation, and automatic timer functions, the BP-2 provides comprehensive control over the fluid dispensing process, enhancing precision.
Compatible with Low-Viscosity Fluids: Perfect for dispensing low-viscosity products such as instant adhesives, inks, and other materials that require high-precision fluid control.
Direct Fluid Dispensing from Original Container: Fluids are directly sucked and dispensed from the original fluid container without the need for compressor air, simplifying the process and ensuring clean dispensing with minimal waste.
Adjustable Discharge Amount for Accuracy: Fine-tune the dispensing volume using a manual or automatic timer function for precise fluid quantity control in various precision dispensing applications.
Product specifications
Model |
RS485(Male), D-SUB 9 pin |
|---|---|
Input/Output Signal |
Shot, Channel No, User Optional / End Signal, Error Signal |
Air IN-Port |
6Ø Air Hose |
Air OUT-Port |
Auto Coupler |
Pressure Regulator |
0~7kgf/㎠ |
Pressure Regulator |
Time / Real |
Display |
4.3" TFT LCD, Touch Panel |
Motor |
DC Servo Motor |
External Control |
Input 8 CH, Output 8 CH |
Channel Memory |
Internal: 200 CH, External: 16 CH |
Consumption Rating |
AC 80~220C(Pre Volt), 50/60Hz |
Operating Temperature |
10~40°C |
Optional System |
Dispensing Pressure Check (for 2 Parts only) |
Dimension & Weight |
220(W) x 224(D) x 120(H)mm / 1.8kg |
Product drawing
No. |
Designation |
Function / Description |
|---|---|---|
① |
TOUCH-LCD |
Screen for displaying the current status and setting menus |
② |
REDGULATOR |
Device for adjusting air pressure |
③ |
SHOT BUTTON |
Button to start/stop dispensing |
④ |
PUMP1 |
Connector for connecting to the main pump |
PUMP2 |
※ When using a single-component material, this connector must be used. |
|
⑤ |
Debug |
Connector for connecting to the curing agent pump |
⑥ |
RS-485 |
※ Connector to be plugged in when using a two-component system |
⑦ |
I/O |
Used for software updates (not available to general users) |
⑧ |
AIR OUT |
Used to connect to a host device. Controlled by the host device using the MODBUS protocol. |
⑨ |
AIR IN: |
Connector for input/output |
⑩ |
SHOT |
Air exhaust port |
⑪ |
P_SEN1 |
Air inlet |
P_SEN2 |
Connector used for external signal control |
|
⑫ |
AC POWER |
Connector for supplying power to the controller |
Detailed specification sheets are shown in the product images.
BP-2 (Progressive cavity pump controller)
BP-2 (Progressive cavity pump controller): overview and buying guide
The BP-2 (Progressive cavity pump controller) (model BP-2) is made by BANSEOK PRECISION and listed in our electronic range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.
Frequently asked questions
How much does the BP-2 (Progressive cavity pump controller) cost?
Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.
Can you ship the BP-2 (Progressive cavity pump controller) to my country?
Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.
Is this a genuine BANSEOK PRECISION product?
We purchase directly from BANSEOK PRECISION or its authorised channels and confirm the model and specifications with the manufacturer before ordering.
What is the minimum order quantity?
For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.
BP-2 (Progressive cavity pump controller)
Main functions and benefits
The BP-2 Progressive Cavity Pump Controller is a high-performance BPP-Series controller designed to regulate the motor connected to the rotor, controlling motor speed up to 120 rpm. It supports both shot and suckback functions, ensuring accurate, repeatable, and precise fluid dispensing. With its real-time mode, the BP-2 offers ON/OFF control or time-setting control, providing versatile operation for a variety of precision fluid applications.
Key Features
Precise Motor Control for Fluid Dispensing: Regulates motor speed up to 120 rpm, ensuring consistent and accurate fluid flow for high-precision applications. Supports both shot and suckback functions for controlled fluid release and cut-off.
Real-Time Mode for Fluid Accuracy: Offers ON/OFF control or time-setting control for enhanced flexibility and precision in dispensing small amounts of fluid.
Smooth Fluid Dispensing: Minimizes tube wear and eliminates pulsation, delivering consistent and reliable fluid flow without disruptions, ensuring high dispensing accuracy in every cycle.
Advanced Liquid Control for Precision Dispensing: Equipped with liquid suction, forward/reverse rotation, and automatic timer functions, the BP-2 provides comprehensive control over the fluid dispensing process, enhancing precision.
Compatible with Low-Viscosity Fluids: Perfect for dispensing low-viscosity products such as instant adhesives, inks, and other materials that require high-precision fluid control.
Direct Fluid Dispensing from Original Container: Fluids are directly sucked and dispensed from the original fluid container without the need for compressor air, simplifying the process and ensuring clean dispensing with minimal waste.
Adjustable Discharge Amount for Accuracy: Fine-tune the dispensing volume using a manual or automatic timer function for precise fluid quantity control in various precision dispensing applications.
Product specifications
Model |
RS485(Male), D-SUB 9 pin |
|---|---|
Input/Output Signal |
Shot, Channel No, User Optional / End Signal, Error Signal |
Air IN-Port |
6Ø Air Hose |
Air OUT-Port |
Auto Coupler |
Pressure Regulator |
0~7kgf/㎠ |
Pressure Regulator |
Time / Real |
Display |
4.3" TFT LCD, Touch Panel |
Motor |
DC Servo Motor |
External Control |
Input 8 CH, Output 8 CH |
Channel Memory |
Internal: 200 CH, External: 16 CH |
Consumption Rating |
AC 80~220C(Pre Volt), 50/60Hz |
Operating Temperature |
10~40°C |
Optional System |
Dispensing Pressure Check (for 2 Parts only) |
Dimension & Weight |
220(W) x 224(D) x 120(H)mm / 1.8kg |
Product drawing
No. |
Designation |
Function / Description |
|---|---|---|
① |
TOUCH-LCD |
Screen for displaying the current status and setting menus |
② |
REDGULATOR |
Device for adjusting air pressure |
③ |
SHOT BUTTON |
Button to start/stop dispensing |
④ |
PUMP1 |
Connector for connecting to the main pump |
PUMP2 |
※ When using a single-component material, this connector must be used. |
|
⑤ |
Debug |
Connector for connecting to the curing agent pump |
⑥ |
RS-485 |
※ Connector to be plugged in when using a two-component system |
⑦ |
I/O |
Used for software updates (not available to general users) |
⑧ |
AIR OUT |
Used to connect to a host device. Controlled by the host device using the MODBUS protocol. |
⑨ |
AIR IN: |
Connector for input/output |
⑩ |
SHOT |
Air exhaust port |
⑪ |
P_SEN1 |
Air inlet |
P_SEN2 |
Connector used for external signal control |
|
⑫ |
AC POWER |
Connector for supplying power to the controller |
Detailed specification sheets are shown in the product images.