Hydraulic and Fluid – illustrative image, not the exact model
New

Air Source Heat Pump IACH-16B

* Product Overview

A system that utilizes the external air for the heat pump to provide heating and hot water

* Features

① A simple system without the need for a device for waste heat collection
② As this system can store hot water in the thermal storage tank, it can be used not only for cooling but also for heating in winter.
③ Unlike an ice thermal storage system, this system is environment-friendly without using a separate low-temperature solution (brine).
④ As this system is simple, it is easy to automatically control and operate it.

* Application

Building cooling / heating or hot water
(all places needing hot water and heating)

* Specification of Air Source Heat Pump (IAVH- 16B, IACK-16C series)

Model IACH-16B-10 IACH-16B-13 IACH-16B-21 IACH-16B-28 IACHK-16C-39
Capacity Heating KW 36.16 45.7 71.44 96.74 137.21
Kcal/h 31,100 39,300 62,300 83,200 118,000
USRT 10.28 13 20.6 27.51 39.02
Cooling KW 34.77 42.21 69.65 88.37 122.09
Kcal/h 29,900 36,300 59,900 76,000 105,000
USRT 9.89 12 19.81 25.13 34.72
Power Supply Heat/Cool KW 13.5/12.9 17.0/16.2 25.3/24.8 37.4/36.2 60.0/55.0
Power Supply 3Phase x 380V x 60Hz
Dimension Length mm 2,040 2,380 2,334 3,480 2,680
Height 1,270 1,370 1,600 2,000 2,290
Depth 710 730 1,110 1,110 2,030
Compressor Type Scroll type Screw
Quantity 1 2 1
Operation Method Direct-on-line Y-
Volume Control % 0~100%
Refrigeration Ton RT 4.12 4.92 8.24 12.35 17.35
Refrigerant Type R-22 R-407C
Control Method Thermostatic expansion valve
Condenser & Evaporator Type Brazed Plate type
Heating
Circulation
Volume
LPM 104 131 208 277 393
Cooling
Circulation
Volume
100 121 200 253 350
Piping(IN/OUT) A 25 25 40 50 65
Outdoor unit Type Finned Copper Tube Type
Thermal Storage Area m2 108.5 128.2 186.5 330.3 522.6
Fan & Motor Air
Volume
m3/min 190 240 510 680 1,080
Size Ø 450x3 500x3 630x3 630x4 700x6
Control Temperature Control 4 way proportional control valve
Operation Control PCB
Defrosting Hot Gas Reverse Cycle
Weight kg 400 550 700 800 1200
Conditions for the products heating Outdoor (DB7°C); Temp of water supply to be 40°C; Temp of output water to be 45°C;
cooling Outdoor (DB25°C); Temp of water supply to be 12°C; Temp of output water to be 70°C;

■ The above specification may vary depending on the site and temperature conditions.
■ The above specification may change without prior notice for further improvement.

Error product group when enable variant picker

Availability: In stock
Hydraulic and Fluid – illustrative image, not the exact model

Air Source Heat Pump IACH-16B

$0.00

Air Source Heat Pump IACH-16B: overview and buying guide

The Air Source Heat Pump IACH-16B (model IACH-16B) is made by IL-JIN E-PLUS and listed in our hydraulic · fluid range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.

Frequently asked questions

How much does the Air Source Heat Pump IACH-16B cost?

Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.

Can you ship the Air Source Heat Pump IACH-16B to my country?

Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.

Is this a genuine IL-JIN E-PLUS product?

We purchase directly from IL-JIN E-PLUS or its authorised channels and confirm the model and specifications with the manufacturer before ordering.

What is the minimum order quantity?

For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.

* Product Overview

A system that utilizes the external air for the heat pump to provide heating and hot water

* Features

① A simple system without the need for a device for waste heat collection
② As this system can store hot water in the thermal storage tank, it can be used not only for cooling but also for heating in winter.
③ Unlike an ice thermal storage system, this system is environment-friendly without using a separate low-temperature solution (brine).
④ As this system is simple, it is easy to automatically control and operate it.

* Application

Building cooling / heating or hot water
(all places needing hot water and heating)

* Specification of Air Source Heat Pump (IAVH- 16B, IACK-16C series)

Model IACH-16B-10 IACH-16B-13 IACH-16B-21 IACH-16B-28 IACHK-16C-39
Capacity Heating KW 36.16 45.7 71.44 96.74 137.21
Kcal/h 31,100 39,300 62,300 83,200 118,000
USRT 10.28 13 20.6 27.51 39.02
Cooling KW 34.77 42.21 69.65 88.37 122.09
Kcal/h 29,900 36,300 59,900 76,000 105,000
USRT 9.89 12 19.81 25.13 34.72
Power Supply Heat/Cool KW 13.5/12.9 17.0/16.2 25.3/24.8 37.4/36.2 60.0/55.0
Power Supply 3Phase x 380V x 60Hz
Dimension Length mm 2,040 2,380 2,334 3,480 2,680
Height 1,270 1,370 1,600 2,000 2,290
Depth 710 730 1,110 1,110 2,030
Compressor Type Scroll type Screw
Quantity 1 2 1
Operation Method Direct-on-line Y-
Volume Control % 0~100%
Refrigeration Ton RT 4.12 4.92 8.24 12.35 17.35
Refrigerant Type R-22 R-407C
Control Method Thermostatic expansion valve
Condenser & Evaporator Type Brazed Plate type
Heating
Circulation
Volume
LPM 104 131 208 277 393
Cooling
Circulation
Volume
100 121 200 253 350
Piping(IN/OUT) A 25 25 40 50 65
Outdoor unit Type Finned Copper Tube Type
Thermal Storage Area m2 108.5 128.2 186.5 330.3 522.6
Fan & Motor Air
Volume
m3/min 190 240 510 680 1,080
Size Ø 450x3 500x3 630x3 630x4 700x6
Control Temperature Control 4 way proportional control valve
Operation Control PCB
Defrosting Hot Gas Reverse Cycle
Weight kg 400 550 700 800 1200
Conditions for the products heating Outdoor (DB7°C); Temp of water supply to be 40°C; Temp of output water to be 45°C;
cooling Outdoor (DB25°C); Temp of water supply to be 12°C; Temp of output water to be 70°C;

■ The above specification may vary depending on the site and temperature conditions.
■ The above specification may change without prior notice for further improvement.