Air Source Heat Pump IACH-16B
* Product Overview
A system that utilizes the external air for the heat pump to provide heating and hot water
* Features
① A simple system without the need for a device for waste heat collection
② As this system can store hot water in the thermal storage tank, it can be used not only for cooling but also for heating in winter.
③ Unlike an ice thermal storage system, this system is environment-friendly without using a separate low-temperature solution (brine).
④ As this system is simple, it is easy to automatically control and operate it.
* Application
Building cooling / heating or hot water
(all places needing hot water and heating)
* Specification of Air Source Heat Pump (IAVH- 16B, IACK-16C series)
| Model | IACH-16B-10 | IACH-16B-13 | IACH-16B-21 | IACH-16B-28 | IACHK-16C-39 | |||
| Capacity | Heating | KW | 36.16 | 45.7 | 71.44 | 96.74 | 137.21 | |
| Kcal/h | 31,100 | 39,300 | 62,300 | 83,200 | 118,000 | |||
| USRT | 10.28 | 13 | 20.6 | 27.51 | 39.02 | |||
| Cooling | KW | 34.77 | 42.21 | 69.65 | 88.37 | 122.09 | ||
| Kcal/h | 29,900 | 36,300 | 59,900 | 76,000 | 105,000 | |||
| USRT | 9.89 | 12 | 19.81 | 25.13 | 34.72 | |||
| Power Supply | Heat/Cool | KW | 13.5/12.9 | 17.0/16.2 | 25.3/24.8 | 37.4/36.2 | 60.0/55.0 | |
| Power Supply | 3Phase x 380V x 60Hz | |||||||
| Dimension | Length | mm | 2,040 | 2,380 | 2,334 | 3,480 | 2,680 | |
| Height | 1,270 | 1,370 | 1,600 | 2,000 | 2,290 | |||
| Depth | 710 | 730 | 1,110 | 1,110 | 2,030 | |||
| Compressor | Type | Scroll type | Screw | |||||
| Quantity | 1 | 2 | 1 | |||||
| Operation Method | Direct-on-line | Y- | ||||||
| Volume Control | % | 0~100% | ||||||
| Refrigeration Ton | RT | 4.12 | 4.92 | 8.24 | 12.35 | 17.35 | ||
| Refrigerant | Type | R-22 | R-407C | |||||
| Control Method | Thermostatic expansion valve | |||||||
| Condenser & Evaporator | Type | Brazed Plate type | ||||||
| Heating Circulation Volume | LPM | 104 | 131 | 208 | 277 | 393 | ||
| Cooling Circulation Volume | 100 | 121 | 200 | 253 | 350 | |||
| Piping(IN/OUT) | A | 25 | 25 | 40 | 50 | 65 | ||
| Outdoor unit | Type | Finned Copper Tube Type | ||||||
| Thermal Storage Area | m2 | 108.5 | 128.2 | 186.5 | 330.3 | 522.6 | ||
| Fan & Motor | Air Volume | m3/min | 190 | 240 | 510 | 680 | 1,080 | |
| Size | Ø | 450x3 | 500x3 | 630x3 | 630x4 | 700x6 | ||
| Control | Temperature Control | 4 way proportional control valve | ||||||
| Operation Control | PCB | |||||||
| Defrosting | Hot Gas | Reverse Cycle | ||||||
| Weight | kg | 400 | 550 | 700 | 800 | 1200 | ||
| Conditions for the products | heating | Outdoor (DB7°C); Temp of water supply to be 40°C; Temp of output water to be 45°C; | ||||||
| cooling | Outdoor (DB25°C); Temp of water supply to be 12°C; Temp of output water to be 70°C; | |||||||
■ The above specification may vary depending on the site and temperature conditions.
■ The above specification may change without prior notice for further improvement.
Air Source Heat Pump IACH-16B
Air Source Heat Pump IACH-16B: overview and buying guide
The Air Source Heat Pump IACH-16B (model IACH-16B) is made by IL-JIN E-PLUS and listed in our hydraulic · fluid range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.
Frequently asked questions
How much does the Air Source Heat Pump IACH-16B cost?
Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.
Can you ship the Air Source Heat Pump IACH-16B to my country?
Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.
Is this a genuine IL-JIN E-PLUS product?
We purchase directly from IL-JIN E-PLUS or its authorised channels and confirm the model and specifications with the manufacturer before ordering.
What is the minimum order quantity?
For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.
* Product Overview
A system that utilizes the external air for the heat pump to provide heating and hot water
* Features
① A simple system without the need for a device for waste heat collection
② As this system can store hot water in the thermal storage tank, it can be used not only for cooling but also for heating in winter.
③ Unlike an ice thermal storage system, this system is environment-friendly without using a separate low-temperature solution (brine).
④ As this system is simple, it is easy to automatically control and operate it.
* Application
Building cooling / heating or hot water
(all places needing hot water and heating)
* Specification of Air Source Heat Pump (IAVH- 16B, IACK-16C series)
| Model | IACH-16B-10 | IACH-16B-13 | IACH-16B-21 | IACH-16B-28 | IACHK-16C-39 | |||
| Capacity | Heating | KW | 36.16 | 45.7 | 71.44 | 96.74 | 137.21 | |
| Kcal/h | 31,100 | 39,300 | 62,300 | 83,200 | 118,000 | |||
| USRT | 10.28 | 13 | 20.6 | 27.51 | 39.02 | |||
| Cooling | KW | 34.77 | 42.21 | 69.65 | 88.37 | 122.09 | ||
| Kcal/h | 29,900 | 36,300 | 59,900 | 76,000 | 105,000 | |||
| USRT | 9.89 | 12 | 19.81 | 25.13 | 34.72 | |||
| Power Supply | Heat/Cool | KW | 13.5/12.9 | 17.0/16.2 | 25.3/24.8 | 37.4/36.2 | 60.0/55.0 | |
| Power Supply | 3Phase x 380V x 60Hz | |||||||
| Dimension | Length | mm | 2,040 | 2,380 | 2,334 | 3,480 | 2,680 | |
| Height | 1,270 | 1,370 | 1,600 | 2,000 | 2,290 | |||
| Depth | 710 | 730 | 1,110 | 1,110 | 2,030 | |||
| Compressor | Type | Scroll type | Screw | |||||
| Quantity | 1 | 2 | 1 | |||||
| Operation Method | Direct-on-line | Y- | ||||||
| Volume Control | % | 0~100% | ||||||
| Refrigeration Ton | RT | 4.12 | 4.92 | 8.24 | 12.35 | 17.35 | ||
| Refrigerant | Type | R-22 | R-407C | |||||
| Control Method | Thermostatic expansion valve | |||||||
| Condenser & Evaporator | Type | Brazed Plate type | ||||||
| Heating Circulation Volume | LPM | 104 | 131 | 208 | 277 | 393 | ||
| Cooling Circulation Volume | 100 | 121 | 200 | 253 | 350 | |||
| Piping(IN/OUT) | A | 25 | 25 | 40 | 50 | 65 | ||
| Outdoor unit | Type | Finned Copper Tube Type | ||||||
| Thermal Storage Area | m2 | 108.5 | 128.2 | 186.5 | 330.3 | 522.6 | ||
| Fan & Motor | Air Volume | m3/min | 190 | 240 | 510 | 680 | 1,080 | |
| Size | Ø | 450x3 | 500x3 | 630x3 | 630x4 | 700x6 | ||
| Control | Temperature Control | 4 way proportional control valve | ||||||
| Operation Control | PCB | |||||||
| Defrosting | Hot Gas | Reverse Cycle | ||||||
| Weight | kg | 400 | 550 | 700 | 800 | 1200 | ||
| Conditions for the products | heating | Outdoor (DB7°C); Temp of water supply to be 40°C; Temp of output water to be 45°C; | ||||||
| cooling | Outdoor (DB25°C); Temp of water supply to be 12°C; Temp of output water to be 70°C; | |||||||
■ The above specification may vary depending on the site and temperature conditions.
■ The above specification may change without prior notice for further improvement.