Air Source Heat Pump IAW(P)-16A Series
* Product Overview
A system that utilizes the external air for the heat pump to provide heating and hot water
* Features
① Simplified system which does not require a waste heat recovery device
② Facilitating up to 70˚C of the water temperature by applying a new refrigerant (IAW Series)
③ Controllable temperature of the output water and stable system by applying the inverter system
④ Enabled to store hot water in the thermal storage tank thereby offering not only the cooling but also the heating functions in winter (IACH Series)
⑤ Simplified system enabling auto control and easy operation
* Application
① Any sector requiring hot water and heating including Hotel, Motel, Dormitory, Hospital, Restaurant (IAW Series)
② Any sector requiring cooling/heating or hot water/cooling /heating (IACH Series)
* Specification of Air Source Heat Pump (IAW-16A series)
| Model | IAW-16A-09 | IAW-16A-13 | IAW-16A-17 | IAW-16A-25 | |||
| Capacity | Heating | KW | 30.29 | 44.51 | 60.59 | 88.7 | |
| Kcal/h | 26,053 | 38,275 | 52,106 | 76,279 | |||
| USRT | 8.62 | 12.66 | 17.23 | 25.22 | |||
| Power Consumption | KW | 12 | 15 | 24 | 36 | ||
| Power Supply | 3Phase x 380V x 60Hz | ||||||
| Dimension | Length | mm | 2,040 | 2,340 | 2,340 | 3,480 | |
| Height | 1,240 | 1,340 | 1,570 | 2,000 | |||
| Depth | 710 | 710 | 1,100 | 1,030 | |||
| Compressor | Type | Scroll type | |||||
| Quantity | 1 | 2 | |||||
| Operation Method | Direct-on-line | ||||||
| Volume Control | % | 0~100% | |||||
| Refrigerant | Refrigeration Ton | RT | 4.32 | 5.6 | 8.64 | 12.52 | |
| Type | R-410A | ||||||
| Control Method | Thermostatic expansion valve | ||||||
| Condenser | Type | Brazed Plate type | |||||
| Circulation Volume | LPM | 11 | 16 | 22 | 32 | ||
| Piping(IN/OUT) | A | 25 | 25 | 40 | 50 | ||
| Outdoor unit | Type | Finned Copper Tube Type | |||||
| Thermal Storage Area | m2 | 108.5 | 128.2 | 186.5 | 330.3 | ||
| Fan & Motor | Air Volume | m3/min | 190 | 240 | 510 | 680 | |
| Size | Ø | 450x3 | 500x3 | 630x3 | 630x4 | ||
| Control | Temperature Control | 4way proportional control valve | |||||
| Operation Control | PCB | ||||||
| Defrosting | Hot Gas | Reverse Cycle | |||||
| Weight | kg | 350 | 500 | 650 | 750 | ||
| Conditions for the products | heating | Outdoor (DB7°C); Temp of water supply to be 30°C; Temp of output water to be 70°C, Δ T=40°C | |||||
■ The above specification may vary depending on the site and temperature conditions.
■ The above specification may change without prior notice for further improvement.
Air Source Heat Pump IAW(P)-16A Series
Air Source Heat Pump IAW(P)-16A Series: overview and buying guide
The Air Source Heat Pump IAW(P)-16A Series (model IAW(P)-16A Series) is made by IL-JIN E-PLUS and listed in our hydraulic · fluid range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.
Frequently asked questions
How much does the Air Source Heat Pump IAW(P)-16A Series cost?
Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.
Can you ship the Air Source Heat Pump IAW(P)-16A Series to my country?
Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.
Is this a genuine IL-JIN E-PLUS product?
We purchase directly from IL-JIN E-PLUS or its authorised channels and confirm the model and specifications with the manufacturer before ordering.
What is the minimum order quantity?
For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.
* Product Overview
A system that utilizes the external air for the heat pump to provide heating and hot water
* Features
① Simplified system which does not require a waste heat recovery device
② Facilitating up to 70˚C of the water temperature by applying a new refrigerant (IAW Series)
③ Controllable temperature of the output water and stable system by applying the inverter system
④ Enabled to store hot water in the thermal storage tank thereby offering not only the cooling but also the heating functions in winter (IACH Series)
⑤ Simplified system enabling auto control and easy operation
* Application
① Any sector requiring hot water and heating including Hotel, Motel, Dormitory, Hospital, Restaurant (IAW Series)
② Any sector requiring cooling/heating or hot water/cooling /heating (IACH Series)
* Specification of Air Source Heat Pump (IAW-16A series)
| Model | IAW-16A-09 | IAW-16A-13 | IAW-16A-17 | IAW-16A-25 | |||
| Capacity | Heating | KW | 30.29 | 44.51 | 60.59 | 88.7 | |
| Kcal/h | 26,053 | 38,275 | 52,106 | 76,279 | |||
| USRT | 8.62 | 12.66 | 17.23 | 25.22 | |||
| Power Consumption | KW | 12 | 15 | 24 | 36 | ||
| Power Supply | 3Phase x 380V x 60Hz | ||||||
| Dimension | Length | mm | 2,040 | 2,340 | 2,340 | 3,480 | |
| Height | 1,240 | 1,340 | 1,570 | 2,000 | |||
| Depth | 710 | 710 | 1,100 | 1,030 | |||
| Compressor | Type | Scroll type | |||||
| Quantity | 1 | 2 | |||||
| Operation Method | Direct-on-line | ||||||
| Volume Control | % | 0~100% | |||||
| Refrigerant | Refrigeration Ton | RT | 4.32 | 5.6 | 8.64 | 12.52 | |
| Type | R-410A | ||||||
| Control Method | Thermostatic expansion valve | ||||||
| Condenser | Type | Brazed Plate type | |||||
| Circulation Volume | LPM | 11 | 16 | 22 | 32 | ||
| Piping(IN/OUT) | A | 25 | 25 | 40 | 50 | ||
| Outdoor unit | Type | Finned Copper Tube Type | |||||
| Thermal Storage Area | m2 | 108.5 | 128.2 | 186.5 | 330.3 | ||
| Fan & Motor | Air Volume | m3/min | 190 | 240 | 510 | 680 | |
| Size | Ø | 450x3 | 500x3 | 630x3 | 630x4 | ||
| Control | Temperature Control | 4way proportional control valve | |||||
| Operation Control | PCB | ||||||
| Defrosting | Hot Gas | Reverse Cycle | |||||
| Weight | kg | 350 | 500 | 650 | 750 | ||
| Conditions for the products | heating | Outdoor (DB7°C); Temp of water supply to be 30°C; Temp of output water to be 70°C, Δ T=40°C | |||||
■ The above specification may vary depending on the site and temperature conditions.
■ The above specification may change without prior notice for further improvement.