* Product Overview

A system that utilizes the external air for the heat pump to provide heating and hot water

* Features

① Simplified system which does not require a waste heat recovery device
② Facilitating up to 70˚C of the water temperature by applying a new refrigerant (IAW Series)
③ Controllable temperature of the output water and stable system by applying the inverter system
④ Enabled to store hot water in the thermal storage tank thereby offering not only the cooling but also the heating functions in winter (IACH Series)
⑤ Simplified system enabling auto control and easy operation

* Application

① Any sector requiring hot water and heating including Hotel, Motel, Dormitory, Hospital, Restaurant (IAW Series)
② Any sector requiring cooling/heating or hot water/cooling /heating (IACH Series)

* Specification of Air Source Heat Pump (IAW-16A series)

Model IAW-16A-09 IAW-16A-13 IAW-16A-17 IAW-16A-25
Capacity Heating KW 30.29 44.51 60.59 88.7
Kcal/h 26,053 38,275 52,106 76,279
USRT 8.62 12.66 17.23 25.22
Power Consumption KW 12 15 24 36
Power Supply 3Phase x 380V x 60Hz
Dimension Length mm 2,040 2,340 2,340 3,480
Height 1,240 1,340 1,570 2,000
Depth 710 710 1,100 1,030
Compressor Type Scroll type
Quantity 1 2
Operation Method Direct-on-line
Volume Control % 0~100%
Refrigerant Refrigeration Ton RT 4.32 5.6 8.64 12.52
Type R-410A
Control Method Thermostatic expansion valve
Condenser Type Brazed Plate type
Circulation Volume LPM 11 16 22 32
Piping(IN/OUT) A 25 25 40 50
Outdoor unit Type Finned Copper Tube Type
Thermal Storage Area m2 108.5 128.2 186.5 330.3
Fan & Motor Air
Volume
m3/min 190 240 510 680
Size Ø 450x3 500x3 630x3 630x4
Control Temperature Control 4way proportional control valve
Operation Control PCB
Defrosting Hot Gas Reverse Cycle
Weight kg 350 500 650 750
Conditions for the products heating Outdoor (DB7°C); Temp of water supply to be 30°C; Temp of output water
to be 70°C, Δ T=40°C

■ The above specification may vary depending on the site and temperature conditions.
■ The above specification may change without prior notice for further improvement.

Error product group when enable variant picker

Availability: In stock
Hydraulic and Fluid – illustrative image, not the exact model

Air Source Heat Pump IAW(P)-16A Series

$0.00

Air Source Heat Pump IAW(P)-16A Series: overview and buying guide

The Air Source Heat Pump IAW(P)-16A Series (model IAW(P)-16A Series) is made by IL-JIN E-PLUS and listed in our hydraulic · fluid range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.

Frequently asked questions

How much does the Air Source Heat Pump IAW(P)-16A Series cost?

Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.

Can you ship the Air Source Heat Pump IAW(P)-16A Series to my country?

Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.

Is this a genuine IL-JIN E-PLUS product?

We purchase directly from IL-JIN E-PLUS or its authorised channels and confirm the model and specifications with the manufacturer before ordering.

What is the minimum order quantity?

For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.

* Product Overview

A system that utilizes the external air for the heat pump to provide heating and hot water

* Features

① Simplified system which does not require a waste heat recovery device
② Facilitating up to 70˚C of the water temperature by applying a new refrigerant (IAW Series)
③ Controllable temperature of the output water and stable system by applying the inverter system
④ Enabled to store hot water in the thermal storage tank thereby offering not only the cooling but also the heating functions in winter (IACH Series)
⑤ Simplified system enabling auto control and easy operation

* Application

① Any sector requiring hot water and heating including Hotel, Motel, Dormitory, Hospital, Restaurant (IAW Series)
② Any sector requiring cooling/heating or hot water/cooling /heating (IACH Series)

* Specification of Air Source Heat Pump (IAW-16A series)

Model IAW-16A-09 IAW-16A-13 IAW-16A-17 IAW-16A-25
Capacity Heating KW 30.29 44.51 60.59 88.7
Kcal/h 26,053 38,275 52,106 76,279
USRT 8.62 12.66 17.23 25.22
Power Consumption KW 12 15 24 36
Power Supply 3Phase x 380V x 60Hz
Dimension Length mm 2,040 2,340 2,340 3,480
Height 1,240 1,340 1,570 2,000
Depth 710 710 1,100 1,030
Compressor Type Scroll type
Quantity 1 2
Operation Method Direct-on-line
Volume Control % 0~100%
Refrigerant Refrigeration Ton RT 4.32 5.6 8.64 12.52
Type R-410A
Control Method Thermostatic expansion valve
Condenser Type Brazed Plate type
Circulation Volume LPM 11 16 22 32
Piping(IN/OUT) A 25 25 40 50
Outdoor unit Type Finned Copper Tube Type
Thermal Storage Area m2 108.5 128.2 186.5 330.3
Fan & Motor Air
Volume
m3/min 190 240 510 680
Size Ø 450x3 500x3 630x3 630x4
Control Temperature Control 4way proportional control valve
Operation Control PCB
Defrosting Hot Gas Reverse Cycle
Weight kg 350 500 650 750
Conditions for the products heating Outdoor (DB7°C); Temp of water supply to be 30°C; Temp of output water
to be 70°C, Δ T=40°C

■ The above specification may vary depending on the site and temperature conditions.