{"product_id":"air-source-heat-pump-129621","title":"Air-source Heat Pump DHB-15","description":"\u003cp\u003e\u003cb\u003eHEAT PUMP\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eHigh-efficiency system capable of air conditioning and heating with one piece of equipment by releasing indoor heat into the atmosphere without a separate cooling tower and it is heated using the heat absorbed from the atmosphere when heating.\u003c\/p\u003e\u003cp\u003eProduce stable high-temperature water by binary cycle method, Extending system life by built-in safety devices, Saving money on fuel cost\u003c\/p\u003e\u003cp\u003e\u003cb\u003eCHARACTERISTIC\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e- It operates to normal without auxiliary heat source in cold weather, 20 degrees below zero\u003c\/p\u003e\u003cp\u003e- The heat pump life is expended sharply with built-un perfect safety devices\u003c\/p\u003e\u003cp\u003e- It is composed of special material(inside) and paint(outside) not to rust\u003c\/p\u003e\u003cp\u003e- By applying anti-vibration device and noise control device, it can be use it conveniently\u003c\/p\u003e\u003cp\u003e-It can be check and control all operation conditions with monitor at counter, main room or convenient place\u003c\/p\u003e\u003cp\u003e\u003cb\u003eBINARY CYCLE\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eExisting Binary Heat pump\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eThe refrigeration standard cycle plays a refrigeration role by repeating and circulating with 4 processes, [compression process → condensation process → expansion process → evaporation process] In case of use it in 4seasons, it’s occurred big problem on evapration process because of calorie deficiency for outdoor air in winter season. Namely, In cold winter season, the refrigerant inhales to compressor in not to evaporate completely because of calorie deficiency.\u003c\/p\u003e\u003cp\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eBinary Heat Pump(Patent Cycle)\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003eThe binary cycle method is using 2 kinds refrigerant which has good absorbing capacity of heat energy R410A and excellent production abliity of high temperature water R-134a.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eFLOW DIAGRAM\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSTANDARD SPECIFICATION\u003c\/b\u003e\u003c\/p\u003e\u003ctable class=\"pem-spec\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eItem\u003c\/td\u003e\n\u003cth\u003eDHB-15\u003c\/th\u003e\n\u003cth\u003eDHB-20\u003c\/th\u003e\n\u003cth\u003eDHB-30\u003c\/th\u003e\n\u003cth\u003eDHS-20\u003c\/th\u003e\n\u003cth\u003eDHS-10\u003c\/th\u003e\n\u003cth\u003eDH-05HG\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth rowspan=\"6\"\u003ePerformance\u003c\/th\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd colspan=\"3\"\u003eBinary-Cycle\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFam-house facilities\u003c\/td\u003e\n\u003ctd\u003eGeothermal-Cylce\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeating capacity(Kcal\/h)\u003c\/th\u003e\n\u003ctd\u003e60,000\u003c\/td\u003e\n\u003ctd\u003e77,000\u003c\/td\u003e\n\u003ctd\u003e110,000\u003c\/td\u003e\n\u003ctd\u003e60,000\u003c\/td\u003e\n\u003ctd\u003e30,000\u003c\/td\u003e\n\u003ctd\u003e19,800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat Storage tank temp.(℃)\u003c\/th\u003e\n\u003ctd\u003e70-75\u003c\/td\u003e\n\u003ctd\u003e70-75\u003c\/td\u003e\n\u003ctd\u003e70-75\u003c\/td\u003e\n\u003ctd\u003e55-60\u003c\/td\u003e\n\u003ctd\u003e55-60\u003c\/td\u003e\n\u003ctd\u003e55-60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWater outlet temp.(℃)\u003c\/th\u003e\n\u003ctd\u003e75-80\u003c\/td\u003e\n\u003ctd\u003e75-80\u003c\/td\u003e\n\u003ctd\u003e75-80\u003c\/td\u003e\n\u003ctd\u003e60-65\u003c\/td\u003e\n\u003ctd\u003e60-65\u003c\/td\u003e\n\u003ctd\u003e60-65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHot water Flow rate (kg\/min)\u003c\/th\u003e\n\u003ctd\u003e165\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003ctd\u003e330\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003e58\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCold capacity(Kcal\/h)\u003c\/th\u003e\n\u003ctd\u003e42,000\u003c\/td\u003e\n\u003ctd\u003e56,000\u003c\/td\u003e\n\u003ctd\u003e70,000\u003c\/td\u003e\n\u003ctd\u003e56,000\u003c\/td\u003e\n\u003ctd\u003e28,000\u003c\/td\u003e\n\u003ctd\u003e21,500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth rowspan=\"3\"\u003eCompressor\u003c\/th\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd colspan=\"6\"\u003eScroll\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeating Power Consumption(Kw\/h)\u003c\/th\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e6.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Power Consumption(Kw\/h)\u003c\/th\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e5.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth rowspan=\"2\"\u003eFan motor\u003c\/th\u003e\n\u003cth\u003eStandard(Φ x Kw x P x EA)\u003c\/th\u003e\n\u003ctd\u003e700 x 0.75 x 6 x 2\u003c\/td\u003e\n\u003ctd\u003e600 x 0.4 x 6 x 3\u003c\/td\u003e\n\u003ctd\u003e750 x 0.75 x 8 x 3\u003c\/td\u003e\n\u003ctd\u003e600 x 0.4 x 6 x 3\u003c\/td\u003e\n\u003ctd\u003e600 x 0.4 x 6 x 2\u003c\/td\u003e\n\u003ctd\u003eX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCMM\u003c\/th\u003e\n\u003ctd\u003e400\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e750\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003ctd\u003eX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth rowspan=\"1\"\u003eWater pipe\u003c\/th\u003e\n\u003cth\u003eIn \/ Out\u003c\/th\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003ctd\u003e50A\u003c\/td\u003e\n\u003ctd\u003e65A\u003c\/td\u003e\n\u003ctd\u003e50A\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003e25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth rowspan=\"1\"\u003eDimension\u003c\/th\u003e\n\u003cth\u003eL x W x H (mm)\u003c\/th\u003e\n\u003ctd\u003e2,070 x 1,000 x\u003cbr\u003e1,775\u003c\/td\u003e\n\u003ctd\u003e2,630 x 900 x\u003cbr\u003e1,775\u003c\/td\u003e\n\u003ctd\u003e3,230 x 1,100 x\u003cbr\u003e2,055\u003c\/td\u003e\n\u003ctd\u003e2,630 x 900 x\u003cbr\u003e1,775\u003c\/td\u003e\n\u003ctd\u003e1,770 x 900 x\u003cbr\u003e1,720\u003c\/td\u003e\n\u003ctd\u003e605 x 780 x\u003cbr\u003e875\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eRefrigerant\u003c\/th\u003e\n\u003ctd\u003eR134A\/R410a\u003c\/td\u003e\n\u003ctd\u003eR134A\/R410a\u003c\/td\u003e\n\u003ctd\u003eR134A\/R410a\u003c\/td\u003e\n\u003ctd\u003eR-407c\u003c\/td\u003e\n\u003ctd\u003eR-407c\u003c\/td\u003e\n\u003ctd\u003eR-410a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eControl of refrigerant\u003cbr\u003e(expansion valve type)\u003c\/th\u003e\n\u003ctd colspan=\"6\"\u003eElectronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eMain Power\u003c\/th\u003e\n\u003ctd colspan=\"6\"\u003e3PH 4-wire 380V 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eFor safety\u003c\/th\u003e\n\u003ctd colspan=\"6\"\u003eNegative-phase detection, Over current relay, High \u0026amp; Low pressure switch,\u003cbr\u003eProtection of compressor overheat, Freeze protection, Flow switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cbr\u003e\u003cp\u003e※Period\u003c\/p\u003e\u003cp\u003e1. Heating Capacity can be changed depend on area in winter season.\u003c\/p\u003e\u003cp\u003e2. Power consumption on heting \u0026amp; cooling is maximum power consumption.\u003c\/p\u003e\u003cp\u003e3. Geothermy heating capacity : load \/ heat source inlet Temp. 40℃\/5℃, Cooling capacity : load \/ heat source inlet Temp. 12℃\/25℃\u003c\/p\u003e\u003cp\u003e\u003cb\u003ePURPOSE OF USE\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eBathing Facilities\/Accommodation Facilities\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSteam baths\u003c\/li\u003e\n\u003cli\u003eSaunas\u003c\/li\u003e\n\u003cli\u003eSteam rooms\u003c\/li\u003e\n\u003cli\u003eSwimming pool\u003c\/li\u003e\n\u003cli\u003eHotels\u003c\/li\u003e\n\u003cli\u003eMotels\u003c\/li\u003e\n\u003cli\u003eDormitories\u003c\/li\u003e\n\u003cli\u003eTraining centers\u003c\/li\u003e\n\u003cli\u003eNursing homes\u003c\/li\u003e\n\u003cli\u003ePension\u003c\/li\u003e\n\u003cli\u003eCondo\u003c\/li\u003e\n\u003cli\u003eStudio apartment\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cbr\u003e\u003cb\u003eAgricultural Facilities\/Religious Facilities\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eVinyl greenhouse\u003c\/li\u003e\n\u003cli\u003eFloricultural pot\u003c\/li\u003e\n\u003cli\u003eRaising seedlings\u003c\/li\u003e\n\u003cli\u003ePig farming, Fish farm\u003c\/li\u003e\n\u003cli\u003eChurches\u003c\/li\u003e\n\u003cli\u003eCathedrals\u003c\/li\u003e\n\u003cli\u003eTemples\u003c\/li\u003e\n\u003cli\u003ePrayer house\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eFor Public Facilities\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eHospitals\u003c\/li\u003e\n\u003cli\u003eSchools\u003c\/li\u003e\n\u003cli\u003eShops\u003c\/li\u003e\n\u003cli\u003eFactories\u003c\/li\u003e\n\u003cli\u003eOffice building\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003eDetailed specification sheets are shown in the product images.\u003c\/em\u003e\u003c\/p\u003e","brand":"DAEHO COOLER","offers":[{"title":"Default Title","offer_id":58446353531220,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1098\/4649\/5572\/files\/daeho-cooler_129621_hlpcmk.jpg?v=1795190715","url":"https:\/\/premiumemart.com\/products\/air-source-heat-pump-129621","provider":"Premium Emart","version":"1.0","type":"link"}