Air-source Heat Pump DHB-15
Air-source Heat Pump DHB-15
Air-source Heat Pump DHB-15
Air-source Heat Pump DHB-15
Air-source Heat Pump DHB-15
Air-source Heat Pump DHB-15
Air-source Heat Pump DHB-15
Air-source Heat Pump DHB-15
New
Air-source Heat Pump DHB-15
Air-source Heat Pump DHB-15
Air-source Heat Pump DHB-15
Air-source Heat Pump DHB-15
Air-source Heat Pump DHB-15
Air-source Heat Pump DHB-15
Air-source Heat Pump DHB-15
Air-source Heat Pump DHB-15

Air-source Heat Pump DHB-15

HEAT PUMP

High-efficiency system capable of air conditioning and heating with one piece of equipment by releasing indoor heat into the atmosphere without a separate cooling tower and it is heated using the heat absorbed from the atmosphere when heating.

Produce stable high-temperature water by binary cycle method, Extending system life by built-in safety devices, Saving money on fuel cost

CHARACTERISTIC

- It operates to normal without auxiliary heat source in cold weather, 20 degrees below zero

- The heat pump life is expended sharply with built-un perfect safety devices

- It is composed of special material(inside) and paint(outside) not to rust

- By applying anti-vibration device and noise control device, it can be use it conveniently

-It can be check and control all operation conditions with monitor at counter, main room or convenient place

BINARY CYCLE

Existing Binary Heat pump

The refrigeration standard cycle plays a refrigeration role by repeating and circulating with 4 processes, [compression process → condensation process → expansion process → evaporation process] In case of use it in 4seasons, it’s occurred big problem on evapration process because of calorie deficiency for outdoor air in winter season. Namely, In cold winter season, the refrigerant inhales to compressor in not to evaporate completely because of calorie deficiency.

Binary Heat Pump(Patent Cycle)

The binary cycle method is using 2 kinds refrigerant which has good absorbing capacity of heat energy R410A and excellent production abliity of high temperature water R-134a.

FLOW DIAGRAM

STANDARD SPECIFICATION

Item DHB-15 DHB-20 DHB-30 DHS-20 DHS-10 DH-05HG
Performance Type Binary-Cycle Fam-house facilities Geothermal-Cylce
Heating capacity(Kcal/h) 60,000 77,000 110,000 60,000 30,000 19,800
Heat Storage tank temp.(℃) 70-75 70-75 70-75 55-60 55-60 55-60
Water outlet temp.(℃) 75-80 75-80 75-80 60-65 60-65 60-65
Hot water Flow rate (kg/min) 165 220 330 200 100 58
Cold capacity(Kcal/h) 42,000 56,000 70,000 56,000 28,000 21,500
Compressor Type Scroll
Heating Power Consumption(Kw/h) 30 40 55 20 10 6.3
Cooling Power Consumption(Kw/h) 15 20 25 20 10 5.7
Fan motor Standard(Φ x Kw x P x EA) 700 x 0.75 x 6 x 2 600 x 0.4 x 6 x 3 750 x 0.75 x 8 x 3 600 x 0.4 x 6 x 3 600 x 0.4 x 6 x 2 X
CMM 400 500 750 500 300 X
Water pipe In / Out 40A 50A 65A 50A 32A 25A
Dimension L x W x H (mm) 2,070 x 1,000 x
1,775
2,630 x 900 x
1,775
3,230 x 1,100 x
2,055
2,630 x 900 x
1,775
1,770 x 900 x
1,720
605 x 780 x
875
Refrigerant R134A/R410a R134A/R410a R134A/R410a R-407c R-407c R-410a
Control of refrigerant
(expansion valve type)
Electronic
Main Power 3PH 4-wire 380V 60Hz
For safety Negative-phase detection, Over current relay, High & Low pressure switch,
Protection of compressor overheat, Freeze protection, Flow switch

※Period

1. Heating Capacity can be changed depend on area in winter season.

2. Power consumption on heting & cooling is maximum power consumption.

3. Geothermy heating capacity : load / heat source inlet Temp. 40℃/5℃, Cooling capacity : load / heat source inlet Temp. 12℃/25℃

PURPOSE OF USE

Bathing Facilities/Accommodation Facilities

  • Steam baths
  • Saunas
  • Steam rooms
  • Swimming pool
  • Hotels
  • Motels
  • Dormitories
  • Training centers
  • Nursing homes
  • Pension
  • Condo
  • Studio apartment


Agricultural Facilities/Religious Facilities

  • Vinyl greenhouse
  • Floricultural pot
  • Raising seedlings
  • Pig farming, Fish farm
  • Churches
  • Cathedrals
  • Temples
  • Prayer house

For Public Facilities

  • Hospitals
  • Schools
  • Shops
  • Factories
  • Office building

Detailed specification sheets are shown in the product images.

Error product group when enable variant picker

Availability: In stock
Categories: HVAC
Air-source Heat Pump DHB-15

Air-source Heat Pump DHB-15

$0.00

Air-source Heat Pump DHB-15: overview and buying guide

The Air-source Heat Pump DHB-15 (model DHB-15) is made by DAEHO COOLER and listed in our hvac range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.

Frequently asked questions

How much does the Air-source Heat Pump DHB-15 cost?

Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.

Can you ship the Air-source Heat Pump DHB-15 to my country?

Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.

Is this a genuine DAEHO COOLER product?

We purchase directly from DAEHO COOLER or its authorised channels and confirm the model and specifications with the manufacturer before ordering.

What is the minimum order quantity?

For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.

HEAT PUMP

High-efficiency system capable of air conditioning and heating with one piece of equipment by releasing indoor heat into the atmosphere without a separate cooling tower and it is heated using the heat absorbed from the atmosphere when heating.

Produce stable high-temperature water by binary cycle method, Extending system life by built-in safety devices, Saving money on fuel cost

CHARACTERISTIC

- It operates to normal without auxiliary heat source in cold weather, 20 degrees below zero

- The heat pump life is expended sharply with built-un perfect safety devices

- It is composed of special material(inside) and paint(outside) not to rust

- By applying anti-vibration device and noise control device, it can be use it conveniently

-It can be check and control all operation conditions with monitor at counter, main room or convenient place

BINARY CYCLE

Existing Binary Heat pump

The refrigeration standard cycle plays a refrigeration role by repeating and circulating with 4 processes, [compression process → condensation process → expansion process → evaporation process] In case of use it in 4seasons, it’s occurred big problem on evapration process because of calorie deficiency for outdoor air in winter season. Namely, In cold winter season, the refrigerant inhales to compressor in not to evaporate completely because of calorie deficiency.

Binary Heat Pump(Patent Cycle)

The binary cycle method is using 2 kinds refrigerant which has good absorbing capacity of heat energy R410A and excellent production abliity of high temperature water R-134a.

FLOW DIAGRAM

STANDARD SPECIFICATION

Item DHB-15 DHB-20 DHB-30 DHS-20 DHS-10 DH-05HG
Performance Type Binary-Cycle Fam-house facilities Geothermal-Cylce
Heating capacity(Kcal/h) 60,000 77,000 110,000 60,000 30,000 19,800
Heat Storage tank temp.(℃) 70-75 70-75 70-75 55-60 55-60 55-60
Water outlet temp.(℃) 75-80 75-80 75-80 60-65 60-65 60-65
Hot water Flow rate (kg/min) 165 220 330 200 100 58
Cold capacity(Kcal/h) 42,000 56,000 70,000 56,000 28,000 21,500
Compressor Type Scroll
Heating Power Consumption(Kw/h) 30 40 55 20 10 6.3
Cooling Power Consumption(Kw/h) 15 20 25 20 10 5.7
Fan motor Standard(Φ x Kw x P x EA) 700 x 0.75 x 6 x 2 600 x 0.4 x 6 x 3 750 x 0.75 x 8 x 3 600 x 0.4 x 6 x 3 600 x 0.4 x 6 x 2 X
CMM 400 500 750 500 300 X
Water pipe In / Out 40A 50A 65A 50A 32A 25A
Dimension L x W x H (mm) 2,070 x 1,000 x
1,775
2,630 x 900 x
1,775
3,230 x 1,100 x
2,055
2,630 x 900 x
1,775
1,770 x 900 x
1,720
605 x 780 x
875
Refrigerant R134A/R410a R134A/R410a R134A/R410a R-407c R-407c R-410a
Control of refrigerant
(expansion valve type)
Electronic
Main Power 3PH 4-wire 380V 60Hz
For safety Negative-phase detection, Over current relay, High & Low pressure switch,
Protection of compressor overheat, Freeze protection, Flow switch

※Period

1. Heating Capacity can be changed depend on area in winter season.

2. Power consumption on heting & cooling is maximum power consumption.

3. Geothermy heating capacity : load / heat source inlet Temp. 40℃/5℃, Cooling capacity : load / heat source inlet Temp. 12℃/25℃

PURPOSE OF USE

Bathing Facilities/Accommodation Facilities

  • Steam baths
  • Saunas
  • Steam rooms
  • Swimming pool
  • Hotels
  • Motels
  • Dormitories
  • Training centers
  • Nursing homes
  • Pension
  • Condo
  • Studio apartment


Agricultural Facilities/Religious Facilities

  • Vinyl greenhouse
  • Floricultural pot
  • Raising seedlings
  • Pig farming, Fish farm
  • Churches
  • Cathedrals
  • Temples
  • Prayer house

For Public Facilities

  • Hospitals
  • Schools
  • Shops
  • Factories
  • Office building

Detailed specification sheets are shown in the product images.