{"product_id":"air-insulated-auto-sectionalizing-switches-49998","title":"Air Insulated Auto Sectionalizing Switches","description":"\u003ch3\u003eCombination AISS\u003c\/h3\u003e\u003cp\u003eThe self-contained Combination AISS combines a newly developed AISS which adopts a CT base insulator patented by Kyungdong Electric, with a current limiting fuse in order to provide user convenience. It is highly efficient for creating package panels.\u003c\/p\u003e\u003cp\u003e■ \u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003ctable class=\"pem-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRated voltage\u003c\/th\u003e\n\u003ctd\u003e25.8㎸\u003c\/td\u003e\n\u003cth\u003eRated breaking current\u003c\/th\u003e\n\u003ctd\u003e900A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated frequency\u003c\/th\u003e\n\u003ctd\u003e60㎐\u003c\/td\u003e\n\u003cth\u003eRated closing current\u003c\/th\u003e\n\u003ctd\u003e15㎄ Asym\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated current\u003c\/th\u003e\n\u003ctd\u003e200A\u003c\/td\u003e\n\u003cth\u003ePower frequency withstand voltage\u003c\/th\u003e\n\u003ctd\u003e50㎸\/ 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth rowspan=\"3\"\u003eRated short time current\u003c\/th\u003e\n\u003ctd\u003e15㎄ Instantaneous Asym\u003c\/td\u003e\n\u003cth\u003eImpulse withstand voltage\u003c\/th\u003e\n\u003ctd\u003e125㎸(1.2X50㎲)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10㎄ 1 second Sym\u003c\/td\u003e\n\u003cth\u003eInrush current restraint time\u003c\/th\u003e\n\u003ctd\u003e0.5, 1.0 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3.5㎄ 10 second Sym\u003c\/td\u003e\n\u003cth\u003eRated control voltage\u003c\/th\u003e\n\u003ctd\u003eDC24V(AC220V Charing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth rowspan=\"2\"\u003eMinimum operation current\u003c\/th\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10, 20, 30, 50, 70, 100, 140, 200A, BLOCK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5, 10, 15, 25, 35, 50, 70, 100A, BY-PASS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLA rating\u003c\/th\u003e\n\u003ctd\u003e18㎸ 2.5\/5㎄\u003c\/td\u003e\n\u003cth\u003eCurrent limiting fuse rating\u003c\/th\u003e\n\u003ctd\u003e24㎸ 5~200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight (excluding fuse)\u003c\/th\u003e\n\u003ctd\u003e76㎏\u003c\/td\u003e\n\u003cth\u003eApplied standards\u003c\/th\u003e\n\u003ctd\u003eKEMC 1126(2007. 8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e■ \u003cstrong\u003eProduct Attributes\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe built-in current transformer base insulator is a product with a simple structure and light weight, in which a current limiting fuse is attached to an AISS that uses a base insulator newly developed by our company. It is a Combination AISS for package switchgears (Patent 10-0875518).\u003c\/p\u003e\u003cp\u003eThe distance between phases is 320㎜, large enough to install a high-capacity fuse.\u003c\/p\u003e\u003cp\u003eIt adopts a polymer base insulator and is light weight.\u003c\/p\u003e\u003cp\u003eProduction orders are also taken for products equipped with porcelain LA (Dimensions are identical to that of polymer LA type.).\u003c\/p\u003e\u003cp\u003e■ \u003cstrong\u003eOperation Functions\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eOvercurrent Protection\u003c\/p\u003e\u003cp\u003eOvercurrent is blocked according to a VI characteristic curve that is maintained for 3 seconds at 1.5 times the minimum operating current correction value.\u003c\/p\u003e\u003cp\u003eCharging Trip\u003c\/p\u003e\u003cp\u003eMomentary operation of the backup protection device enables an automatic trip while the fault current is removed (Does not open when AISS is in normal operation.). This function separates the fault current automatically by opening the AISS.\u003c\/p\u003e\u003cp\u003eInrush Current Restraint\u003c\/p\u003e\u003cp\u003ePrevents malfunction by restraining the inrush current from the transformer or motor.\u003c\/p\u003e\u003cp\u003eOvercurrent Lock\u003c\/p\u003e\u003cp\u003eThe switch locks when abnormal rating lock current (800A) occurs. This function automatically separates the fault section by opening the AISS after blocking the backup protection device.\u003c\/p\u003e\u003ch3\u003eAISS\u003c\/h3\u003e\u003cp\u003eKyungdong Electric's Air-Insulated Auto-Sectionalizing Switch is the first indoor type switch developed in Korea with its brand name registered as AISS. It cooperates with the backup protective device and blocks the fault section automatically. It is installed on the customer’s faucet penetration point in which the load capacity of the substation CB or recloser is below 4,000kVA (special load 2,000kVA) on a 22.9kV-y distribution line.\u003c\/p\u003e\u003cp\u003e■ \u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003ctable class=\"pem-spec\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecifications\u003c\/th\u003e\n\u003ctd\u003e25.8㎸\u003c\/td\u003e\n\u003cth\u003eRated breaking current\u003c\/th\u003e\n\u003ctd\u003e900A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated frequency\u003c\/th\u003e\n\u003ctd\u003e60㎐\u003c\/td\u003e\n\u003cth\u003eRated closing current\u003c\/th\u003e\n\u003ctd\u003e15㎄ Asym\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated current\u003c\/th\u003e\n\u003ctd\u003e200A\u003c\/td\u003e\n\u003cth\u003ePower frequency withstand voltage\u003c\/th\u003e\n\u003ctd\u003e60㎸\/ 1min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth rowspan=\"3\"\u003eRated short time current\u003c\/th\u003e\n\u003ctd\u003e15㎄ Instantaneous Asym\u003c\/td\u003e\n\u003cth\u003eImpulse withstand voltage\u003c\/th\u003e\n\u003ctd\u003e150㎸(1.2X50㎲)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10㎄ 1 second Sym\u003c\/td\u003e\n\u003cth\u003eInrush current restraint time\u003c\/th\u003e\n\u003ctd\u003e0.5, 1.0 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3.5㎄ 10 second Sym\u003c\/td\u003e\n\u003cth\u003eRated control voltage\u003c\/th\u003e\n\u003ctd\u003eDC24V(AC220V Charing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth rowspan=\"2\"\u003eMinimum operation current\u003c\/th\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10, 20, 30, 50, 70, 100, 140, 200A, BLOCK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5, 10, 15, 25, 35, 50, 70, 100A, BY-PASS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e■ \u003cstrong\u003eProduct Attributes\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eBase insulator with a built-in current transformer\u003c\/p\u003e\u003cp\u003eThis compact, light-weight base insulator newly developed by Kyungdong dramatically reduces the size and weight of the AISS. It is small enough to install in a space for general LBS (Patent Application No. 10-2008-0046262).\u003c\/p\u003e\u003cp\u003eManual operating mechanism\u003c\/p\u003e\u003cp\u003eThis product offers convenient manual operation at any place by simply fixing the cable without requiring a separate operating mechanism.\u003c\/p\u003e\u003cp\u003eControl box\u003c\/p\u003e\u003cp\u003eThis product is designed so that it can be directly attached to the switchboard door, offering convenient management and control of the AISS operating status. Its push-type button correction tap allows the user to easily correct and check the current (Utility Model Registration No. 0182617).\u003c\/p\u003e\u003cp\u003eOperating function\u003c\/p\u003e\u003cp\u003eOperating function\u003c\/p\u003e\u003cp\u003e■ \u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cem\u003eDetailed specification sheets are shown in the product images.\u003c\/em\u003e\u003c\/p\u003e","brand":"Kyungdong Electric","offers":[{"title":"Default Title","offer_id":58447141634388,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1098\/4649\/5572\/files\/kyungdong-electric-co-ltd_49998_ippxsf.jpg?v=1795192537","url":"https:\/\/premiumemart.com\/products\/air-insulated-auto-sectionalizing-switches-49998","provider":"Premium Emart","version":"1.0","type":"link"}