Air Circuit Breakers
Characteristics
Compact & Modular design
|
High breaking capacity
- HITACHI ACB provides high breaking capacity up to 100kA
Safety and Convenience
- OCR terminals are located in front
- Modulized mechanical part and accessories
- for easy maintenance and inspection Improved draw-out rail for easy draw-out
- Minimized arc space
- Molded frame
high functional digital type trip relay
- Easy inspection by LCD
-Load current value
-Setting values of each trip characteristics
-Fault current(Max) value
-Tripping time - Self-diagnosis function
-noEr : No error
-Err-1 : NoMTD coil
-Err-2 : Program error
-Err-4 : Configuration resister error
-Err-8 : Watch dog error - Self-test function
-It is available to check whether OCR is operated normally or not by applying external power - Pre-alarm function
- Contact output of the each tripping cause and LED indication
- OCR alarm contact (AL,2a)
Variety of accessories
Optional accessories
- Interlock device
-MI (Mechanical Interlock) - Key interlock, ON-Lock (K2)
- Key lock (K1)
- ON/OFF button lock (B)
- Door Frame (DF)
- Door Interlock (DI)
- UVT, UVT controller : Standard (1NO 1NC)
| TYPE | Operating time | Rated voltage | |
|---|---|---|---|
| Instantaneous type | under 0.2sec | AC | 110, 220, 380, 460V |
| DC | 24, 48, 110, 125V | ||
| Delay type | over 0.5sec | AC | 110, 220, 380, 460V |
| DC | 24, 48, 110, 125V | ||
| over 3sec | AC | 110, 220, 380, 460V | |
| DC | — | ||
- Cell switch (4C,8C)
- Shorting "b" contact (SBC, 5b max, Shorting b contact)
- Safety shutter lock (STL)
- Miss insertion prevent device (MIP)
- Condenser tripping device (CTD)
- OCR tester (OT)
Standard attachment of draw-out type
- pad lock
- Position indicator (connected, test, disconnected)
- Counter (5-digit)
- Lifting hook
- Insulating barrier
- OCR alarm contact (AL,2a)
Ratings
400A — 1600A
| TYPE | AK-06***C | AK-08***C | AK-10***C | AK-13***C | AK-16***C | |||||
|---|---|---|---|---|---|---|---|---|---|---|
| Rated current (In max) | (A) | 630, 400 | 800 | 1000 | 1250 | 1600 | ||||
| Rated operating voltage (Ue) | (V) | 690 | 690 | 690 | 690 | 690 | ||||
| Rated insulation voltage (Ui) | (V) | 1000 | 1000 | 1000 | 1000 | 1000 | ||||
| Frequency *2 | (Hz) | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | ||||
| Number of poles | (P) | 3, 4 | 3, 4 | 3, 4 | 3, 4 | 3, 4 | ||||
| Setting current (In) | (A) | OCR-II | For industry | In max.×1.0-0.9-0.8-0.7-0.6-0.5-0.4(7 Steps) | ||||||
| OCR-III *3 | For industry | In max.×1.0-0.9-0.8-0.7-0.6-0.5-0.4-0.3-0.2 (9 Steps) | ||||||||
| For generator protection | In max.×1.0-0.9-0.8-0.7-0.6-0.5-0.4-0.3-0.2 (9 Steps) | |||||||||
| Rated current of neutral pole | (A) | 630 | 800 | 1000 | 1250 | 1600 | ||||
| Rated breaking capacity(Sym) (Icu) | (kA) | IEC60947-2 AC | 690V | 50 | 50 | 50 | 50 | 50 | ||
| 600V | 50 | 50 | 50 | 50 | 50 | |||||
| 500V Under | 65 | 65 | 65 | 65 | 65 | |||||
| Rated service breaking capacity (Ics) | (kA) | …%×Icu | 100% | 100% | 100% | 100% | 100% | |||
| Rated making capacity(peak) (Icm) | (kA) | IEC60947-2 AC | 690V | 105 | 105 | 105 | 105 | 105 | ||
| 600V | 105 | 105 | 105 | 105 | 105 | |||||
| 500V Under | 143 | 143 | 143 | 143 | 143 | |||||
| Rated short-time capacity (Icw) | (kA) | 1 sec | 65 | 65 | 65 | 65 | 65 | |||
| 2 sec | 40 | 40 | 40 | 40 | 40 | |||||
| 3 sec | 30 | 30 | 30 | 30 | 30 | |||||
| operating time (t) | (ms) | Maximum total breaking time | 40 | 40 | 40 | 40 | 40 | |||
| Closing time | 80 | 80 | 80 | 80 | 80 | |||||
| Life cycle | (time) | Mechanical | Without maintenance | 12000 | 12000 | 12000 | 12000 | 12000 | ||
| With maintenance | 20000 | 20000 | 20000 | 20000 | 20000 | |||||
| Electrical | Without maintenance | 3000 | 3000 | 3000 | 3000 | 3000 | ||||
| With maintenance | 5000 | 5000 | 5000 | 5000 | 5000 | |||||
| Weight (3P/4P) | (kg) | Draw-out type | Main body (with cradle) | Motor charging type | 66/80 | 67/81 | 67/81 | 67/81 | 67/81 | |
| Manual charging type | 63/77 | 64/78 | 64/78 | 64/78 | 64/78 | |||||
| Cradle only | 26/30 | 26/30 | 26/30 | 26/30 | 26/30 | |||||
| Fixed type | Motor charging type | 43/53 | 44/54 | 44/54 | 44/54 | 44/54 | ||||
| Manual charging type | 40/50 | 41/51 | 41/51 | 41/51 | 41/51 | |||||
| Bus-bar | Connection type | Horizontal type *4 | Standard | Standard | Standard | Standard | Standard | |||
| Vertical type | Option | Option | Option | Option | Option | |||||
| Closing type | Motor charging type | Standard | Standard | Standard | Standard | Standard | ||||
| Manual charging type | Option | Option | Option | Option | Option | |||||
| External dimension | Draw-out type | (mm) | H : 435, D : 479 | W (3P/4P) | 350/435 | 350/435 | 350/435 | 350/435 | 350/435 | |
| Fixed type | (mm) | H : 410, D : 375 | W (3P/4P) | 345/430 | 345/430 | 345/430 | 345/430 | 345/430 | ||
2000A — 5000A
| TYPE | AK-20***C | AK-25***C | AK-32***C | AK-40***C | AK-50***C | |||||
|---|---|---|---|---|---|---|---|---|---|---|
| Rated current (In max) | (A) | 2000 | 2500 | 3200(3150) *1 | 4000 | 5000 | ||||
| Rated operating voltage (Ue) | (V) | 690 | 690 | 690 | 690 | 690 | ||||
| Rated insulation voltage (Ui) | (V) | 1000 | 1000 | 1000 | 1000 | 1000 | ||||
| Frequency *2 | (Hz) | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | ||||
| Number of poles | (P) | 3, 4 | 3, 4 | 3, 4 | 3, 4 | 3, 4 | ||||
| Setting current (In) | (A) | OCR-II | For industry | In max.×1.0-0.9-0.8-0.7-0.6-0.5-0.4(7 Steps) | ||||||
| OCR-III *3 | For industry | In max.×1.0-0.9-0.8-0.7-0.6-0.5-0.4-0.3-0.2(9 Steps) | ||||||||
| For generator protection | In max.×1.0-0.9-0.8-0.7-0.6-0.5-0.4-0.3-0.2(9 Steps) | |||||||||
| Rated current of neutral pole | (A) | 2000 | 2500 | 3200 | 2500 | 2500 | ||||
| Rated breaking capacity(Sym) (Icu) | (kA) | IEC60947-2 AC | 690V | 50 | 50 | 50 | 50 | 50 | ||
| 600V | 65 | 65 | 65 | 85 | 85 | |||||
| 500V Under | 85 | 85 | 85 | 100 | 100 | |||||
| Rated service breaking capacity (Ics) | (kA) | …%×Icu | 100% | 100% | 100% | 100% | 100% | |||
| Rated making capacity(peak) (Icm) | (kA) | IEC60947-2 AC | 690V | 105 | 105 | 105 | 105 | 105 | ||
| 600V | 143 | 143 | 143 | 187 | 187 | |||||
| 500V Under | 187 | 187 | 187 | 220 | 220 | |||||
| Rated short-time capacity (Icw) | (kA) | 1 sec | 65 | 65 | 65 | 85 | 85 | |||
| 2 sec | 60 | 60 | 60 | 65 | 65 | |||||
| 3 sec | 60 | 60 | 60 | 65 | 65 | |||||
| operating time (t) | (ms) | Maximum total breaking time | 40 | 40 | 40 | 40 | 40 | |||
| Closing time | 80 | 80 | 80 | 80 | 80 | |||||
| Life cycle | (time) | Mechanical | Without maintenance | 10000 | 10000 | 10000 | 10000 | 10000 | ||
| With maintenance | 20000 | 20000 | 20000 | 20000 | 20000 | |||||
| Electrical | Without maintenance | 3000 | 3000 | 3000 | 3000 | 3000 | ||||
| With maintenance | 5000 | 5000 | 5000 | 5000 | 5000 | |||||
| Weight (3P/4P) | (kg) | Draw-out type | Main body (with cradle) | Motor charging type | 95/116 | 96/117 | 98/119 | 244/267 | 244/267 | |
| Manual charging type | 92/113 | 93/114 | 95/116 | 240/263 | 240/263 | |||||
| Cradle only | 35/43 | 35/43 | 36/44 | 125/140 | 125/140 | |||||
| Fixed type | Motor charging type | 63/75 | 64/76 | 66/78 | 119/127 | 119/127 | ||||
| Manual charging type | 60/72 | 61/73 | 63/75 | 115/123 | 115/123 | |||||
| Bus-bar | Connection type | Horizontal type *5 | Standard | Standard | Standard | Standard offer in the fixed type | ||||
| Vertical type | Option | Option | Option | Standard offer in the draw-out type | ||||||
| Closing type | Motor charging type | Standard | Standard | Standard | Standard | Standard | ||||
| Manual charging type | Option | Option | Option | Option | Option | |||||
| External dimension | Draw-out type | (mm) | H : 435, D : 479 | W (3P/4P) | 485/615 | 485/615 | 485/615 | 960/1090 | 960/1090 | |
| Fixed type | (mm) | H : 410, D : 375 | W (3P/4P) | 480/610 | 480/610 | 480/610 | 870/1000 | 870/1000 | ||
Note
*1 Rated current of IEC standard
*2 Trip relay is divided into 50Hz and 60Hz. Please be careful when you order it.
*3 The generator protection relay is only available in OCR-III.
*4 For mainbody, only horizontal type is available. For cradle, vertical type is optional. In case of vertical type use of the horizontal type, the user needs to apply the vertical adapter, The vertical type is standard for 4000/500AF.
*5 For 4000/5000AF, height is 455mm
Charging method
Manual charging type
The closing coil is charged by manual charging handle. For closing, first charge the spring by using the charging handle, and then press the close button(I, ON) for closing, the open button(O, OFF) for opening
|
Motor charging type
The closing spring is charged by a motor ON charging method or OFF charging method is available selectively.
-OFF charging method : When the breaker is opened, the closing spring is charged automatically. It can change to ON charging method by removing b(A×b) contact like beside circuit diagram
-ON charging method : The closing spring is charged automatically when the breaker is closed.It can change to OFF charging method by using b(A×b) contact. There is a contact to indicate the charging completion(TS+, TS-). Since the contact signal of charging completion switch is connected to the external terminal, It is easy to construct a circuit(ex.Automatic closing circuit) by using that contact
- Manual charging is also available
- With the breaker closed(I, ON), only manual charging is possible(motor charging cannot be performed)
- With the open button(O, OFF) pressed, closing cannot be performed(electrical and mechanical lock)
- When OFF Lock device is in use, closing cannot be worked.(electrical and mechanical lock)
- Opening should follow at least one second after completion of charging
- Pumping prevent circuit is included with the closing coil(electrical lock)
- Please note that pumping prevent circuit can be reset when the voltage of input signal drops
| Voltage | Reset voltage |
| AC | Rated voltage 85% under |
| DC | Rated voltage 85% under |
Motor charging circuit
Note
*1 Since charging completion contact (TS+, TS-) terminal is for contact output power should not be allowed.
*2 Charging completion contact capacity is equal to that high of capacity of auxiliary contact in page 27.
Motor ratings
| Rated voltage | Inrush current peak value(A) | Steady current(A) | Power consumption(W) | Charging time(sec) | |
| AC/DC 50/60Hz | 110 | 7 | 3.5 | 385 | 5 Under |
| 220 | 7 | 3.5 | 770 | ||
| DC | 125 | 7 | 3.5 | 437 | |
| 24 | 30 | 11 | 264 | ||
| 48 | 30 | 5.5 | 264 | ||
Note
*The range of operating voltage : 85-110%
Auxiliary devices
1:Pad lock(PL)
To fix a ACB into a position (Dis-connected, Test, Connected)
* Standard offer in the draw-out type
2:Position Indicator
To indicate the position (Dis-connected, Test, Connected)of a ACB
* Standard offer in the draw-out type
3:Closing Coil(CC)
- To close the breaker by remote control
- The coil only operates when the power is supplied continuously over 100ms
- Power should be supplied separately from the moer charging power.
- Electric pumping prevent circuit is built in it.
| Rated voltage(V) | Operational voltage (V) | Inrush current peak value(A) | Steady current(A) | Closing time(sec) | |
| AC/DC 50/60Hz | 110 | 94-121 | 2 | 1 | 0.08 Under |
| 220 | 187-242 | 3 | 1.3 | ||
| DC | 125 | 106-138 | 2.3 | 1 | |
| 24 | 21-26V | 30 | 3.5 | ||
| 48 | 41-53V | 30 | 7 | ||
Note
*1 Closing time is from coil excitation to contact closing
*2 Steady current is the value at maximum rated voltage
*3 Please be careful that the pumping prevention circuit is reset when its voltage is under 85% of the rated voltage
*4 The extent of operation voltage is 85-110% of the rated voltage
4:Shunt coil(SHT)
- To open the breaker by remote control
- Use an auxiliary contact(INO) to prevent coil burnig
- When the control power is 'OFF' at the ACB is 'ON' state, the ACB remains 'ON'
| Rated voltage(V) | Operational voltage (V) | Inrush current peak value(A) | Steady current(A) | Closing time(sec) | |
|---|---|---|---|---|---|
| AC/DC 50/60Hz | 110 | 77-121 | 2 | 1 | 0.04 Under |
| 220 | 154-242 | 3 | 1.3 | ||
| DC | 125 | 88-138 | 2.3 | 1 | |
| 24 | 21-26V | 30 | 3.5 | ||
| 48 | 41-53V | 30 | 7 | ||
Note
* The extent of operation voltage is 70-110% of the rated voltage.
5:OCR Alarm contact
OCR alarm contact is fundamentally installed in only ACB with trip relay.
When the ACB is tripped by the OCR operation, electrical signal flows through the OCR alarm contact for remote supervisory(INO).
Contact type
| TYPE | OCR-II | OCR-III |
|---|---|---|
| Operational type | Momentary operation type (Under 15ms) | Magnetic maintenance type |
| Formation of contact | 2NO | 2NO |
Operating condition of contact
| Condition of circuit breaker | Cause of trip | Condition of "a" contact |
|---|---|---|
| TRIP | Long-time delay trip, Short-time delay trip, Instantaneous-time delay trip, Ground fault trip | ON |
| Trip button, Shunt trip coil (SHT), Undervoltage trip (UVT) | OFF | |
| ON | OFF | |
| OFF | OFF |
Pumping prevent circuit
Trip coil circuit
Contact capacity
| TYPE | Capacity | |
|---|---|---|
| Ratings | AC | 250V 5A |
| DC | 30V 5A | |
| Rated current | 5A | |
| Maximum contact voltage | AC | 380V |
| DC | 125V | |
| Maximum contact current | 5A | |
| Minimum applicable load | DC | 5V 10mA |
Detailed specification sheets are shown in the product images.
Air Circuit Breakers
Air Circuit Breakers: overview and buying guide
The Air Circuit Breakers is made by HITACHI INDUSTRIAL EQUIPMENT SYSTEMS and listed in our electronic range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.
Frequently asked questions
How much does the Air Circuit Breakers cost?
Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.
Can you ship the Air Circuit Breakers to my country?
Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.
Is this a genuine HITACHI INDUSTRIAL EQUIPMENT SYSTEMS product?
We purchase directly from HITACHI INDUSTRIAL EQUIPMENT SYSTEMS or its authorised channels and confirm the model and specifications with the manufacturer before ordering.
What is the minimum order quantity?
For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.
Characteristics
Compact & Modular design
|
High breaking capacity
- HITACHI ACB provides high breaking capacity up to 100kA
Safety and Convenience
- OCR terminals are located in front
- Modulized mechanical part and accessories
- for easy maintenance and inspection Improved draw-out rail for easy draw-out
- Minimized arc space
- Molded frame
high functional digital type trip relay
- Easy inspection by LCD
-Load current value
-Setting values of each trip characteristics
-Fault current(Max) value
-Tripping time - Self-diagnosis function
-noEr : No error
-Err-1 : NoMTD coil
-Err-2 : Program error
-Err-4 : Configuration resister error
-Err-8 : Watch dog error - Self-test function
-It is available to check whether OCR is operated normally or not by applying external power - Pre-alarm function
- Contact output of the each tripping cause and LED indication
- OCR alarm contact (AL,2a)
Variety of accessories
Optional accessories
- Interlock device
-MI (Mechanical Interlock) - Key interlock, ON-Lock (K2)
- Key lock (K1)
- ON/OFF button lock (B)
- Door Frame (DF)
- Door Interlock (DI)
- UVT, UVT controller : Standard (1NO 1NC)
| TYPE | Operating time | Rated voltage | |
|---|---|---|---|
| Instantaneous type | under 0.2sec | AC | 110, 220, 380, 460V |
| DC | 24, 48, 110, 125V | ||
| Delay type | over 0.5sec | AC | 110, 220, 380, 460V |
| DC | 24, 48, 110, 125V | ||
| over 3sec | AC | 110, 220, 380, 460V | |
| DC | — | ||
- Cell switch (4C,8C)
- Shorting "b" contact (SBC, 5b max, Shorting b contact)
- Safety shutter lock (STL)
- Miss insertion prevent device (MIP)
- Condenser tripping device (CTD)
- OCR tester (OT)
Standard attachment of draw-out type
- pad lock
- Position indicator (connected, test, disconnected)
- Counter (5-digit)
- Lifting hook
- Insulating barrier
- OCR alarm contact (AL,2a)
Ratings
400A — 1600A
| TYPE | AK-06***C | AK-08***C | AK-10***C | AK-13***C | AK-16***C | |||||
|---|---|---|---|---|---|---|---|---|---|---|
| Rated current (In max) | (A) | 630, 400 | 800 | 1000 | 1250 | 1600 | ||||
| Rated operating voltage (Ue) | (V) | 690 | 690 | 690 | 690 | 690 | ||||
| Rated insulation voltage (Ui) | (V) | 1000 | 1000 | 1000 | 1000 | 1000 | ||||
| Frequency *2 | (Hz) | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | ||||
| Number of poles | (P) | 3, 4 | 3, 4 | 3, 4 | 3, 4 | 3, 4 | ||||
| Setting current (In) | (A) | OCR-II | For industry | In max.×1.0-0.9-0.8-0.7-0.6-0.5-0.4(7 Steps) | ||||||
| OCR-III *3 | For industry | In max.×1.0-0.9-0.8-0.7-0.6-0.5-0.4-0.3-0.2 (9 Steps) | ||||||||
| For generator protection | In max.×1.0-0.9-0.8-0.7-0.6-0.5-0.4-0.3-0.2 (9 Steps) | |||||||||
| Rated current of neutral pole | (A) | 630 | 800 | 1000 | 1250 | 1600 | ||||
| Rated breaking capacity(Sym) (Icu) | (kA) | IEC60947-2 AC | 690V | 50 | 50 | 50 | 50 | 50 | ||
| 600V | 50 | 50 | 50 | 50 | 50 | |||||
| 500V Under | 65 | 65 | 65 | 65 | 65 | |||||
| Rated service breaking capacity (Ics) | (kA) | …%×Icu | 100% | 100% | 100% | 100% | 100% | |||
| Rated making capacity(peak) (Icm) | (kA) | IEC60947-2 AC | 690V | 105 | 105 | 105 | 105 | 105 | ||
| 600V | 105 | 105 | 105 | 105 | 105 | |||||
| 500V Under | 143 | 143 | 143 | 143 | 143 | |||||
| Rated short-time capacity (Icw) | (kA) | 1 sec | 65 | 65 | 65 | 65 | 65 | |||
| 2 sec | 40 | 40 | 40 | 40 | 40 | |||||
| 3 sec | 30 | 30 | 30 | 30 | 30 | |||||
| operating time (t) | (ms) | Maximum total breaking time | 40 | 40 | 40 | 40 | 40 | |||
| Closing time | 80 | 80 | 80 | 80 | 80 | |||||
| Life cycle | (time) | Mechanical | Without maintenance | 12000 | 12000 | 12000 | 12000 | 12000 | ||
| With maintenance | 20000 | 20000 | 20000 | 20000 | 20000 | |||||
| Electrical | Without maintenance | 3000 | 3000 | 3000 | 3000 | 3000 | ||||
| With maintenance | 5000 | 5000 | 5000 | 5000 | 5000 | |||||
| Weight (3P/4P) | (kg) | Draw-out type | Main body (with cradle) | Motor charging type | 66/80 | 67/81 | 67/81 | 67/81 | 67/81 | |
| Manual charging type | 63/77 | 64/78 | 64/78 | 64/78 | 64/78 | |||||
| Cradle only | 26/30 | 26/30 | 26/30 | 26/30 | 26/30 | |||||
| Fixed type | Motor charging type | 43/53 | 44/54 | 44/54 | 44/54 | 44/54 | ||||
| Manual charging type | 40/50 | 41/51 | 41/51 | 41/51 | 41/51 | |||||
| Bus-bar | Connection type | Horizontal type *4 | Standard | Standard | Standard | Standard | Standard | |||
| Vertical type | Option | Option | Option | Option | Option | |||||
| Closing type | Motor charging type | Standard | Standard | Standard | Standard | Standard | ||||
| Manual charging type | Option | Option | Option | Option | Option | |||||
| External dimension | Draw-out type | (mm) | H : 435, D : 479 | W (3P/4P) | 350/435 | 350/435 | 350/435 | 350/435 | 350/435 | |
| Fixed type | (mm) | H : 410, D : 375 | W (3P/4P) | 345/430 | 345/430 | 345/430 | 345/430 | 345/430 | ||
2000A — 5000A
| TYPE | AK-20***C | AK-25***C | AK-32***C | AK-40***C | AK-50***C | |||||
|---|---|---|---|---|---|---|---|---|---|---|
| Rated current (In max) | (A) | 2000 | 2500 | 3200(3150) *1 | 4000 | 5000 | ||||
| Rated operating voltage (Ue) | (V) | 690 | 690 | 690 | 690 | 690 | ||||
| Rated insulation voltage (Ui) | (V) | 1000 | 1000 | 1000 | 1000 | 1000 | ||||
| Frequency *2 | (Hz) | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | ||||
| Number of poles | (P) | 3, 4 | 3, 4 | 3, 4 | 3, 4 | 3, 4 | ||||
| Setting current (In) | (A) | OCR-II | For industry | In max.×1.0-0.9-0.8-0.7-0.6-0.5-0.4(7 Steps) | ||||||
| OCR-III *3 | For industry | In max.×1.0-0.9-0.8-0.7-0.6-0.5-0.4-0.3-0.2(9 Steps) | ||||||||
| For generator protection | In max.×1.0-0.9-0.8-0.7-0.6-0.5-0.4-0.3-0.2(9 Steps) | |||||||||
| Rated current of neutral pole | (A) | 2000 | 2500 | 3200 | 2500 | 2500 | ||||
| Rated breaking capacity(Sym) (Icu) | (kA) | IEC60947-2 AC | 690V | 50 | 50 | 50 | 50 | 50 | ||
| 600V | 65 | 65 | 65 | 85 | 85 | |||||
| 500V Under | 85 | 85 | 85 | 100 | 100 | |||||
| Rated service breaking capacity (Ics) | (kA) | …%×Icu | 100% | 100% | 100% | 100% | 100% | |||
| Rated making capacity(peak) (Icm) | (kA) | IEC60947-2 AC | 690V | 105 | 105 | 105 | 105 | 105 | ||
| 600V | 143 | 143 | 143 | 187 | 187 | |||||
| 500V Under | 187 | 187 | 187 | 220 | 220 | |||||
| Rated short-time capacity (Icw) | (kA) | 1 sec | 65 | 65 | 65 | 85 | 85 | |||
| 2 sec | 60 | 60 | 60 | 65 | 65 | |||||
| 3 sec | 60 | 60 | 60 | 65 | 65 | |||||
| operating time (t) | (ms) | Maximum total breaking time | 40 | 40 | 40 | 40 | 40 | |||
| Closing time | 80 | 80 | 80 | 80 | 80 | |||||
| Life cycle | (time) | Mechanical | Without maintenance | 10000 | 10000 | 10000 | 10000 | 10000 | ||
| With maintenance | 20000 | 20000 | 20000 | 20000 | 20000 | |||||
| Electrical | Without maintenance | 3000 | 3000 | 3000 | 3000 | 3000 | ||||
| With maintenance | 5000 | 5000 | 5000 | 5000 | 5000 | |||||
| Weight (3P/4P) | (kg) | Draw-out type | Main body (with cradle) | Motor charging type | 95/116 | 96/117 | 98/119 | 244/267 | 244/267 | |
| Manual charging type | 92/113 | 93/114 | 95/116 | 240/263 | 240/263 | |||||
| Cradle only | 35/43 | 35/43 | 36/44 | 125/140 | 125/140 | |||||
| Fixed type | Motor charging type | 63/75 | 64/76 | 66/78 | 119/127 | 119/127 | ||||
| Manual charging type | 60/72 | 61/73 | 63/75 | 115/123 | 115/123 | |||||
| Bus-bar | Connection type | Horizontal type *5 | Standard | Standard | Standard | Standard offer in the fixed type | ||||
| Vertical type | Option | Option | Option | Standard offer in the draw-out type | ||||||
| Closing type | Motor charging type | Standard | Standard | Standard | Standard | Standard | ||||
| Manual charging type | Option | Option | Option | Option | Option | |||||
| External dimension | Draw-out type | (mm) | H : 435, D : 479 | W (3P/4P) | 485/615 | 485/615 | 485/615 | 960/1090 | 960/1090 | |
| Fixed type | (mm) | H : 410, D : 375 | W (3P/4P) | 480/610 | 480/610 | 480/610 | 870/1000 | 870/1000 | ||
Note
*1 Rated current of IEC standard
*2 Trip relay is divided into 50Hz and 60Hz. Please be careful when you order it.
*3 The generator protection relay is only available in OCR-III.
*4 For mainbody, only horizontal type is available. For cradle, vertical type is optional. In case of vertical type use of the horizontal type, the user needs to apply the vertical adapter, The vertical type is standard for 4000/500AF.
*5 For 4000/5000AF, height is 455mm
Charging method
Manual charging type
The closing coil is charged by manual charging handle. For closing, first charge the spring by using the charging handle, and then press the close button(I, ON) for closing, the open button(O, OFF) for opening
|
Motor charging type
The closing spring is charged by a motor ON charging method or OFF charging method is available selectively.
-OFF charging method : When the breaker is opened, the closing spring is charged automatically. It can change to ON charging method by removing b(A×b) contact like beside circuit diagram
-ON charging method : The closing spring is charged automatically when the breaker is closed.It can change to OFF charging method by using b(A×b) contact. There is a contact to indicate the charging completion(TS+, TS-). Since the contact signal of charging completion switch is connected to the external terminal, It is easy to construct a circuit(ex.Automatic closing circuit) by using that contact
- Manual charging is also available
- With the breaker closed(I, ON), only manual charging is possible(motor charging cannot be performed)
- With the open button(O, OFF) pressed, closing cannot be performed(electrical and mechanical lock)
- When OFF Lock device is in use, closing cannot be worked.(electrical and mechanical lock)
- Opening should follow at least one second after completion of charging
- Pumping prevent circuit is included with the closing coil(electrical lock)
- Please note that pumping prevent circuit can be reset when the voltage of input signal drops
| Voltage | Reset voltage |
| AC | Rated voltage 85% under |
| DC | Rated voltage 85% under |
Motor charging circuit
Note
*1 Since charging completion contact (TS+, TS-) terminal is for contact output power should not be allowed.
*2 Charging completion contact capacity is equal to that high of capacity of auxiliary contact in page 27.
Motor ratings
| Rated voltage | Inrush current peak value(A) | Steady current(A) | Power consumption(W) | Charging time(sec) | |
| AC/DC 50/60Hz | 110 | 7 | 3.5 | 385 | 5 Under |
| 220 | 7 | 3.5 | 770 | ||
| DC | 125 | 7 | 3.5 | 437 | |
| 24 | 30 | 11 | 264 | ||
| 48 | 30 | 5.5 | 264 | ||
Note
*The range of operating voltage : 85-110%
Auxiliary devices
1:Pad lock(PL)
To fix a ACB into a position (Dis-connected, Test, Connected)
* Standard offer in the draw-out type
2:Position Indicator
To indicate the position (Dis-connected, Test, Connected)of a ACB
* Standard offer in the draw-out type
3:Closing Coil(CC)
- To close the breaker by remote control
- The coil only operates when the power is supplied continuously over 100ms
- Power should be supplied separately from the moer charging power.
- Electric pumping prevent circuit is built in it.
| Rated voltage(V) | Operational voltage (V) | Inrush current peak value(A) | Steady current(A) | Closing time(sec) | |
| AC/DC 50/60Hz | 110 | 94-121 | 2 | 1 | 0.08 Under |
| 220 | 187-242 | 3 | 1.3 | ||
| DC | 125 | 106-138 | 2.3 | 1 | |
| 24 | 21-26V | 30 | 3.5 | ||
| 48 | 41-53V | 30 | 7 | ||
Note
*1 Closing time is from coil excitation to contact closing
*2 Steady current is the value at maximum rated voltage
*3 Please be careful that the pumping prevention circuit is reset when its voltage is under 85% of the rated voltage
*4 The extent of operation voltage is 85-110% of the rated voltage
4:Shunt coil(SHT)
- To open the breaker by remote control
- Use an auxiliary contact(INO) to prevent coil burnig
- When the control power is 'OFF' at the ACB is 'ON' state, the ACB remains 'ON'
| Rated voltage(V) | Operational voltage (V) | Inrush current peak value(A) | Steady current(A) | Closing time(sec) | |
|---|---|---|---|---|---|
| AC/DC 50/60Hz | 110 | 77-121 | 2 | 1 | 0.04 Under |
| 220 | 154-242 | 3 | 1.3 | ||
| DC | 125 | 88-138 | 2.3 | 1 | |
| 24 | 21-26V | 30 | 3.5 | ||
| 48 | 41-53V | 30 | 7 | ||
Note
* The extent of operation voltage is 70-110% of the rated voltage.
5:OCR Alarm contact
OCR alarm contact is fundamentally installed in only ACB with trip relay.
When the ACB is tripped by the OCR operation, electrical signal flows through the OCR alarm contact for remote supervisory(INO).
Contact type
| TYPE | OCR-II | OCR-III |
|---|---|---|
| Operational type | Momentary operation type (Under 15ms) | Magnetic maintenance type |
| Formation of contact | 2NO | 2NO |
Operating condition of contact
| Condition of circuit breaker | Cause of trip | Condition of "a" contact |
|---|---|---|
| TRIP | Long-time delay trip, Short-time delay trip, Instantaneous-time delay trip, Ground fault trip | ON |
| Trip button, Shunt trip coil (SHT), Undervoltage trip (UVT) | OFF | |
| ON | OFF | |
| OFF | OFF |
Pumping prevent circuit
Trip coil circuit
Contact capacity
| TYPE | Capacity | |
|---|---|---|
| Ratings | AC | 250V 5A |
| DC | 30V 5A | |
| Rated current | 5A | |
| Maximum contact voltage | AC | 380V |
| DC | 125V | |
| Maximum contact current | 5A | |
| Minimum applicable load | DC | 5V 10mA |
Detailed specification sheets are shown in the product images.