After Cooler HYA-Series
Product
● The heat transfer coefficient and durability is nice because the adhesion between cooper tube and fin is good
● IP54 class axial fan is applied
● Upon request for customer-engineered products
· Various control devices and electrical contact are available
· Various electrical
Specification
GSA - Englishpressure0.3 kgf/cm2
Max working pressure
14.0 kgf/cm2Ambient temperature2℃ ~ 40℃
Max ambient temperature80℃
Air-cooled
| Model HYA - | Applicable compressor [HP] | Flow rate [Nm³/min] | Connection | Fan motor | Dimension [mm] | Weight [kg] | ||
| Diameter [mm] | Width | Leight | Height | |||||
| 20A | 7.5 | 1.0 | 25A | 230 x 1 | 230 | 500 | 590 | 15 |
| 25A | 25.0 | 3.2 | 25A | 230 x 1 | 230 | 500 | 590 | 16 |
| 40A | 35.0 | 5.1 | 25A | 300 x 1 | 300 | 600 | 700 | 23 |
| 50A | 50.0 | 7.8 | 40A | 250 x 2 | 370 | 900 | 710 | 40 |
| 80A | 75.0 | 12.7 | 50A | 300 x 2 | 370 | 1,030 | 810 | 46 |
| 100A | 130.0 | 17.5 | 50A | 350 x 2 | 400 | 1,160 | 825 | 55 |
| 150A | 170.0 | 28.0 | 80A | 450 x 2 | 460 | 1,690 | 1,095 | 180 |
| 200A | 200.0 | 41.0 | 100A | 500 x 2 | 425 | 1,780 | 1,245 | 210 |
| 300A | 300.0 | 52.0 | 100A | 550 x 2 | 480 | 1,880 | 1,360 | 230 |
| 400A | 400.0 | 65.0 | 125A | 450 x 4 | 470 | 1,830 | 1,615 | 300 |
| 500A | 500.0 | 75.0 | 150A | 500 x 4 | 475 | 1,975 | 1,685 | 350 |
| 600A | 600.0 | 95.0 | 150A | 550 x 4 | 530 | 2,075 | 1,840 | 370 |
Water-cooled
| Model HYA - | 냉각수량 /min | Flow rate [Nm³/min] | 전열면적 m² | Dimension [mm] | Weight [kg] | ||
| A | B | C | |||||
| 100w | 55 | 18 | 2.1 | 1,280 | 1,080 | 155 | 112 |
| 200w | 105 | 30 | 3.1 | 1,450 | 1,230 | 155 | 121 |
| 300w | 155 | 36 | 5.1 | 1,780 | 1,580 | 168 | 163 |
| 400w | 210 | 42 | 5.9 | 1,900 | 1,700 | 180 | 233 |
| 500w | 270 | 60 | 6.3 | 2,000 | 1,750 | 180 | 253 |
| 600w | 320 | 90 | 11.7 | 2,100 | 1,850 | 210 | 410 |
NOTE
1. Max inlet temperature is 80℃.
2. Bigger capacity can be supplied upon request.
3, The specification can be changed without notice to improve the products.
Catalogues
After Cooler HYA-Series
After Cooler HYA-Series: overview and buying guide
The After Cooler HYA-Series (model HYA-Series) is made by GSA and listed in our hvac range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.
Frequently asked questions
How much does the After Cooler HYA-Series cost?
Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.
Can you ship the After Cooler HYA-Series to my country?
Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.
Is this a genuine GSA product?
We purchase directly from GSA or its authorised channels and confirm the model and specifications with the manufacturer before ordering.
What is the minimum order quantity?
For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.
Product
● The heat transfer coefficient and durability is nice because the adhesion between cooper tube and fin is good
● IP54 class axial fan is applied
● Upon request for customer-engineered products
· Various control devices and electrical contact are available
· Various electrical
Specification
GSA - Englishpressure0.3 kgf/cm2
Max working pressure
14.0 kgf/cm2Ambient temperature2℃ ~ 40℃
Max ambient temperature80℃
Air-cooled
| Model HYA - | Applicable compressor [HP] | Flow rate [Nm³/min] | Connection | Fan motor | Dimension [mm] | Weight [kg] | ||
| Diameter [mm] | Width | Leight | Height | |||||
| 20A | 7.5 | 1.0 | 25A | 230 x 1 | 230 | 500 | 590 | 15 |
| 25A | 25.0 | 3.2 | 25A | 230 x 1 | 230 | 500 | 590 | 16 |
| 40A | 35.0 | 5.1 | 25A | 300 x 1 | 300 | 600 | 700 | 23 |
| 50A | 50.0 | 7.8 | 40A | 250 x 2 | 370 | 900 | 710 | 40 |
| 80A | 75.0 | 12.7 | 50A | 300 x 2 | 370 | 1,030 | 810 | 46 |
| 100A | 130.0 | 17.5 | 50A | 350 x 2 | 400 | 1,160 | 825 | 55 |
| 150A | 170.0 | 28.0 | 80A | 450 x 2 | 460 | 1,690 | 1,095 | 180 |
| 200A | 200.0 | 41.0 | 100A | 500 x 2 | 425 | 1,780 | 1,245 | 210 |
| 300A | 300.0 | 52.0 | 100A | 550 x 2 | 480 | 1,880 | 1,360 | 230 |
| 400A | 400.0 | 65.0 | 125A | 450 x 4 | 470 | 1,830 | 1,615 | 300 |
| 500A | 500.0 | 75.0 | 150A | 500 x 4 | 475 | 1,975 | 1,685 | 350 |
| 600A | 600.0 | 95.0 | 150A | 550 x 4 | 530 | 2,075 | 1,840 | 370 |
Water-cooled
| Model HYA - | 냉각수량 /min | Flow rate [Nm³/min] | 전열면적 m² | Dimension [mm] | Weight [kg] | ||
| A | B | C | |||||
| 100w | 55 | 18 | 2.1 | 1,280 | 1,080 | 155 | 112 |
| 200w | 105 | 30 | 3.1 | 1,450 | 1,230 | 155 | 121 |
| 300w | 155 | 36 | 5.1 | 1,780 | 1,580 | 168 | 163 |
| 400w | 210 | 42 | 5.9 | 1,900 | 1,700 | 180 | 233 |
| 500w | 270 | 60 | 6.3 | 2,000 | 1,750 | 180 | 253 |
| 600w | 320 | 90 | 11.7 | 2,100 | 1,850 | 210 | 410 |
NOTE
1. Max inlet temperature is 80℃.
2. Bigger capacity can be supplied upon request.