{"product_id":"2-channel-smoke-sensor-55047","title":"2-Channel Smoke Sensor SD-110","description":"\u003cp\u003eSD-110 is a microprocessor internal 2-channel smoke detector. \u003cbr\u003e SD-110 is an environment-adaptive smoke detector which displays the concentration on the back light LCD by receiving the serial signals from two sensors and by processing them in the digital mode, and performs the variety of local functions in digital process mode. \u003cbr\u003e Also, it can ensure the effective remote control by stably outputting the analog serial signals to external control unit such as PLC\/DDC.\u003cbr\u003e As one of big advantages of SD-110, it can be suitably applicable for various purposes by processing the sensible signals detected by ionization sensor by microprocessor stably and accurately.\u003cbr\u003e Because the existing smoke detectors have been mostly applied only for a fire alarm, it is general that they don’t ensure an accuracy and safety for a utility of industrial field.\u003cbr\u003e SD-110 is designed to ensure a sensibility and safety simultaneously by controlling the sensible ionization sensor with an industrial detector technology.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e[ Features ] \u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eㆍ Low Concentrated Smoke Detection \u003cbr\u003e It is suitable to a small quantity smoke detection because it is designed for a purpose of supporting the safety function of industrial automation equipment. \u003cbr\u003e ㆍ Ionization sensor : Ionization sensor using the current change when the smoke is combined in the ion created by radial rays can detect very low concentrated smoke. \u003cbr\u003e ㆍ LCD Display with Back-Light \u003cbr\u003e ㆍ Local Alarm \u003cbr\u003e It can set the alarm concentration by microprocessor. When the detection concentration is larger than the alarm concentration, over 80㏈ alarm sound is generated. It informs whether the smoke occurs. \u003cbr\u003e ㆍ User Selection Menu \u003cbr\u003e It is organized suitably for the purpose of use because various artificial intellectuals are provided by microprocessor. It maximizes the effect of detection function because various functions such as alarm concentration setting, detection range setting, and alarm reset setting are properly used. \u003cbr\u003e ㆍ Two–Channel Detection \u003cbr\u003e It can monitor the maximum 2 ionization sensor at the same time and can extend the detection space. \u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e[ Specification ]\u003c\/strong\u003e \u003c\/p\u003e \u003ctable class=\"pem-spec\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd colspan=\"2\"\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003e\u003cstrong\u003eClassification \u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eSD - 110 \u003c\/strong\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eGeneral Type\u003c\/td\u003e \u003ctd\u003e1 or 2 Channel Monitoring\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eProduct Type\u003c\/td\u003e \u003ctd\u003eWall type\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDetection Principle\u003c\/td\u003e \u003ctd\u003eIonizations Smoke Chamber\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDetection Type\u003c\/td\u003e \u003ctd\u003eDiffusion Type\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eResponse Time\u003c\/td\u003e \u003ctd\u003eLess 5 sec.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDetection Range\u003c\/td\u003e \u003ctd\u003e0 ~ 500 Pcs\/L\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eExternal Output\u003c\/td\u003e \u003ctd\u003e4 ~ 20㎃\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePower Source\u003c\/td\u003e \u003ctd\u003eDC 24V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAlarm Type\u003c\/td\u003e \u003ctd\u003eHigh \/ Low 2 Step Alarm – User setting\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAlarm Reset\u003c\/td\u003e \u003ctd\u003eManual or automatic – User selection\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSignal Wire\u003c\/td\u003e \u003ctd\u003eCVVS \u0026amp; CVVSB 1.25sq x 3 Wire - Shield Type\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAvailable Current\u003c\/td\u003e \u003ctd\u003e500㎃. Maximum\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSystem Initialization Time\u003c\/td\u003e \u003ctd\u003eLess 50 sec.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eExternal Structure\u003c\/td\u003e \u003ctd\u003eMonitoring Unit - Metal, Sensor Unit - Aluminum\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTemperature\/Humidity\u003c\/td\u003e \u003ctd\u003e-20℃~ 50℃ \/ 0 ~ 95% RH (Non-Condensing)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eProcess\u003c\/td\u003e \u003ctd\u003eDigital Process\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\u003ch3\u003eCatalogues\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/premiumemart.com\/cdn\/shop\/files\/pem-f-66e0ffe252be14cf.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSD-110  Spec\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"GASDNA","offers":[{"title":"Default Title","offer_id":58446033846612,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1098\/4649\/5572\/files\/gasdna_55047_ynpqvi.jpg?v=1795189865","url":"https:\/\/premiumemart.com\/products\/2-channel-smoke-sensor-55047","provider":"Premium Emart","version":"1.0","type":"link"}