Tension Load Cell STL
Tension Load Cell
This large-capacity cylindrical load cell is specifically used for weighing offshore plants, particularly those with steel structures. This digital load cell with a built-in microprocessor offers easy setup of live loads, error messages, and remote control. Sealed in a cylindrical shape, this load cell is corrosion-resistant and durable for the harshest environments requiring high capacity and an IP68 waterproof rating.
[Features]
Real-time load display
Easy operation using remote control
Voltage and communication (RS-422) output proportional to the load [option]
[Function]
Real-time load display using the front monitor
Output (0~5V)
Real-time stain gauge voltage display
Zero point adjustment using remote control
Mode selection function using remote control [strain gage output, actual weight
-
Display
- Actual weight
- Load cell output signal
- Error message
[Specifications]
Supply voltage: VDC7Volts~VDC20Volts
Power consumption: Max. 0.3Watts
Usage temperature: -10 degree C.~70 degree C.
Storage temperature: -20℃ ~ +70℃
Humidity: Under 95%RH
[ Detailed specifications]
MODEL |
STL |
STLX |
STLY |
|
|---|---|---|---|---|
Rated Capacity |
50, 100, 200, 300, 500kg. 1, 2, 3, 5, 10, 25t |
|||
Rated Output |
3.0mV/V±0.1% |
3.0mV/V±0.2% |
||
Nonlinearity |
≤0.02% R.O. |
≤0.05% R.O. |
≤0.1% R.O. |
|
Hysteresis |
≤0.02% R.O. |
≤0.1% R.O. |
||
Repeatability |
≤0.02% R.O. |
≤0.1% R.O. |
||
Creep |
≤0.02%in 20min |
≤0.1%in 20min |
||
Zero Balance |
≤1% R.O. |
|||
Temperature Compensation Range |
-10~70℃ |
|||
Permissible Temperature Range |
-20~80℃ |
|||
Temperature Effect on Output |
≤0.03% LOAD/10℃ |
≤0.05% LOAD/10℃ |
||
Temperature Effect on Zero |
≤0.03% R.O./10℃ |
≤0.05% R.O./10℃ |
||
Input Resistance |
350 Ohms ± 3.5 Ohms |
|||
Output Resistance |
350 Ohms ± 5 0hms |
|||
Insulation Resistance |
5000 MOhms at 50V DC |
2000 MOhms at 50V DC |
||
Applied Voltage |
10V(Recommended) / 15V(Maximum) |
|||
Cable Specifications |
Ø 9mmx3m (22AWGx4C, Shielded) |
|||
Dust and Moisture Resistance Rating |
meets IP 67 |
|||
Allowable Overload |
150% R.C. |
|||
Final Overload |
300% R.C. |
|||
※ STLs: Stainless Steel / STLm: When equipped with an embedded monitor
[Dimensions(mm)]
Rated capacity |
A |
B |
C |
D |
E |
F |
G |
H |
J |
K |
Rod end |
Weight(kg) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
50~ 300kg |
88 |
10 |
35 |
228 |
34 |
16 |
12 |
41 |
M12x1.25, Depth13 |
115 |
SRTL-1 |
2.8 |
500 ~ 1000kg |
88 |
106 |
33 |
224 |
34 |
16 |
12 |
41 |
M12x1.25, Depth13 |
115 |
SRTL-1 |
2.8 |
2~5t |
88 |
145 |
52.5 |
319 |
62 |
28 |
22 |
55 |
M24x2.0, Depth30 |
115 |
SRTL-2 |
4.5 |
10t |
138 |
210 |
70 |
510 |
100 |
43 |
40 |
100 |
M39x2.0, Depth50 |
171 |
SRTL-3 |
12.5 |
20t |
164 |
283 |
120 |
635 |
120 |
53 |
50 |
115 |
M50x2.0, Depth65 |
189 |
SRTL-4 |
27.4 |
Detailed specification sheets are shown in the product images.
Tension Load Cell STL
Tension Load Cell STL: overview and buying guide
The Tension Load Cell STL (model STL) is made by SHINHAN ELECTRIONICS and listed in our test · measurement range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.
Frequently asked questions
How much does the Tension Load Cell STL cost?
Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.
Can you ship the Tension Load Cell STL to my country?
Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.
Is this a genuine SHINHAN ELECTRIONICS product?
We purchase directly from SHINHAN ELECTRIONICS or its authorised channels and confirm the model and specifications with the manufacturer before ordering.
What is the minimum order quantity?
For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.
Tension Load Cell
This large-capacity cylindrical load cell is specifically used for weighing offshore plants, particularly those with steel structures. This digital load cell with a built-in microprocessor offers easy setup of live loads, error messages, and remote control. Sealed in a cylindrical shape, this load cell is corrosion-resistant and durable for the harshest environments requiring high capacity and an IP68 waterproof rating.
[Features]
Real-time load display
Easy operation using remote control
Voltage and communication (RS-422) output proportional to the load [option]
[Function]
Real-time load display using the front monitor
Output (0~5V)
Real-time stain gauge voltage display
Zero point adjustment using remote control
Mode selection function using remote control [strain gage output, actual weight
-
Display
- Actual weight
- Load cell output signal
- Error message
[Specifications]
Supply voltage: VDC7Volts~VDC20Volts
Power consumption: Max. 0.3Watts
Usage temperature: -10 degree C.~70 degree C.
Storage temperature: -20℃ ~ +70℃
Humidity: Under 95%RH
[ Detailed specifications]
MODEL |
STL |
STLX |
STLY |
|
|---|---|---|---|---|
Rated Capacity |
50, 100, 200, 300, 500kg. 1, 2, 3, 5, 10, 25t |
|||
Rated Output |
3.0mV/V±0.1% |
3.0mV/V±0.2% |
||
Nonlinearity |
≤0.02% R.O. |
≤0.05% R.O. |
≤0.1% R.O. |
|
Hysteresis |
≤0.02% R.O. |
≤0.1% R.O. |
||
Repeatability |
≤0.02% R.O. |
≤0.1% R.O. |
||
Creep |
≤0.02%in 20min |
≤0.1%in 20min |
||
Zero Balance |
≤1% R.O. |
|||
Temperature Compensation Range |
-10~70℃ |
|||
Permissible Temperature Range |
-20~80℃ |
|||
Temperature Effect on Output |
≤0.03% LOAD/10℃ |
≤0.05% LOAD/10℃ |
||
Temperature Effect on Zero |
≤0.03% R.O./10℃ |
≤0.05% R.O./10℃ |
||
Input Resistance |
350 Ohms ± 3.5 Ohms |
|||
Output Resistance |
350 Ohms ± 5 0hms |
|||
Insulation Resistance |
5000 MOhms at 50V DC |
2000 MOhms at 50V DC |
||
Applied Voltage |
10V(Recommended) / 15V(Maximum) |
|||
Cable Specifications |
Ø 9mmx3m (22AWGx4C, Shielded) |
|||
Dust and Moisture Resistance Rating |
meets IP 67 |
|||
Allowable Overload |
150% R.C. |
|||
Final Overload |
300% R.C. |
|||
※ STLs: Stainless Steel / STLm: When equipped with an embedded monitor
[Dimensions(mm)]
Rated capacity |
A |
B |
C |
D |
E |
F |
G |
H |
J |
K |
Rod end |
Weight(kg) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
50~ 300kg |
88 |
10 |
35 |
228 |
34 |
16 |
12 |
41 |
M12x1.25, Depth13 |
115 |
SRTL-1 |
2.8 |
500 ~ 1000kg |
88 |
106 |
33 |
224 |
34 |
16 |
12 |
41 |
M12x1.25, Depth13 |
115 |
SRTL-1 |
2.8 |
2~5t |
88 |
145 |
52.5 |
319 |
62 |
28 |
22 |
55 |
M24x2.0, Depth30 |
115 |
SRTL-2 |
4.5 |
10t |
138 |
210 |
70 |
510 |
100 |
43 |
40 |
100 |
M39x2.0, Depth50 |
171 |
SRTL-3 |
12.5 |
20t |
164 |
283 |
120 |
635 |
120 |
53 |
50 |
115 |
M50x2.0, Depth65 |
189 |
SRTL-4 |
27.4 |
Detailed specification sheets are shown in the product images.