Programmable Logic Controllers MICRO-EHV+ Series
Features
Powerful communication performance in one CPU
All models have Ethernet, serial, USB (host & device) communication ports as standard.
Additional communication ports can be realized by option boards.
Wide range of expansion units are available
MICRO-EHV+ Basic unit
No. of I/O is Max. 320 (using 64 pts expansion unit)
Specification
Basic units
I/O external connection : Removable type screw terminal block (M3)
[CPU specification]
| Item | 40 points type | 64 points type | |
|---|---|---|---|
| Platform | CODESYS Runtime V3.5 SP3 Patch4 | ||
| Boolean execution speed | 0.54µs/instruction | ||
| User Program memory | 1MB | ||
| Source file memory | 1MB | ||
| Data memory (non retain) | 640KB | ||
| Data memory (retain) | 256KB | ||
| Programming languages | IEC61131-3 compliant 5 languages (LD, FBD, SFC, IL, ST) | ||
| No. of expansion unit | 4 | ||
| No. of I/O (using 64pts exp. units) | 296 (In 184 / Out 112) | 320 (In 200 / Out 120) | |
| Special I/O | Single phase counter | Max. 5ch, 100kHz | |
| 2 phase counter | Max. 2ch, 60kHz | ||
| Pulse train output | Max. 3ch, 65kHz | ||
| PWM output | Max. 3ch, 65kHz | ||
| Interrupt | Max. 5ch | ||
| I/O updating cycle | Refresh processing (depends on each task cycle) | ||
| USB | Device function | For programming. Built-in USB 2.0 Full speed | |
| Host function | USB stick can be used for a copy of project and data logging | ||
| Ethernet | UDP/IP, TCP/IP | Programming, General purpose, Modbus-TCP server/client, EtherCAT® master | |
| Serial | RS-232C (Built-in) | General purpose, Modbus-RTU master and slave | |
| RS-485 (Option) | General purpose, Modbus-RTU master and slave | ||
| Web visualization function | Support | ||
| RTC | Built-in | ||
| Battery | Optional | ||
[Basic units]
| Class | Model Name | Specification | |||
|---|---|---|---|---|---|
| Power | Input | Output | Remarks | ||
| 40 points | MV-D40DTPS | 24V DC | DC24V × 24 | Transistor × 16 (short circuit protection) | Source |
| MV-D40DT | 24V DC | DC24V × 24 | Transistor × 16 | Sink | |
| MV-D40DR | 24V DC | DC24V × 24 | Relay × 16 | ||
| MV-A40DR | 100/200V AC | DC24V × 24 | Relay × 16 | ||
| 64 points | MV-D64DTPS | 24V DC | DC24V × 40 | Transistor × 24 (short circuit protection) | Source |
| MV-D64DT | 24V DC | DC24V × 40 | Transistor × 24 | Sink | |
| MV-D64DR | 24V DC | DC24V × 40 | Relay × 24 | ||
| MV-A64DR | 100/200V AC | DC24V × 40 | Relay × 24 | ||
[Expansion units]
| Class | Model Name | Specification | |||
|---|---|---|---|---|---|
| Power | Input | Output | Remarks | ||
| 8 points | EH-D8ED | 24V DC | 24VDC × 8 | - | |
| EH-D8ER | 24V DC | - | Relay × 8 | ||
| EH-D8ETPS | 24V DC | - | Transistor × 8 (short circuit protection) | Source | |
| EH-D8ET | 24V DC | - | Transistor × 8 | Sink | |
| ED-D8EDTPS | 24V DC | 24VDC × 4 | Transistor × 4 (short circuit protection) | Source | |
| EH-D8EDT | 24V DC | 24VDC × 4 | Transistor × 4 | Sink | |
| EH-D8EDR | 24V DC | 24VDC × 4 | Relay × 4 | ||
| 14 points | EH-D14EDTPS | 24V DC | 24VDC × 8 | Transistor × 6 (short circuit protection) | Source |
| EH-D14EDTP | 24V DC | 24VDC × 8 | Transistor × 6 | Source | |
| EH-D14EDT | 24V DC | 24VDC × 8 | Transistor × 6 | Sink | |
| EH-D14EDR | 24V DC | 24VDC × 8 | Relay × 6 | ||
| EH-A14EDR | 100/200V AC | 24VDC × 8 | Relay × 6 | ||
| 16 points | EH-D16ED | 24V DC | 24VDC × 16 | - | |
| EH-D16ER | 24V DC | - | Relay × 16 | ||
| EH-D16ETPS | 24V DC | - | Transistor × 16 (short circuit protection) | Source | |
| EH-D16ET | 24V DC | - | Transistor × 16 | Sink | |
| 28 points | EH-D28EDTPS | 24V DC | 24VDC × 16 | Transistor × 12 (short circuit protection) | Source |
| EH-D28EDTP | 24V DC | 24VDC × 16 | Transistor × 12 | Source | |
| EH-D28EDT | 24V DC | 24VDC × 16 | Transistor × 12 | Sink | |
| EH-D28EDR | 24V DC | 24VDC × 16 | Relay × 12 | ||
| EH-A28EDR | 100/200V AC | 24VDC × 16 | Relay × 12 | ||
| 64 points | EH-D64EDTPS | 24V DC | 24VDC × 40 | Transistor × 24 (short circuit protection) | Source |
| EH-D64EDT | 24V DC | 24VDC × 40 | Transistor × 24 | Sink | |
| EH-D64EDR | 24V DC | 24VDC × 40 | Relay × 24 | ||
| EH-A64EDR | 100/200V AC | 24VDC × 40 | Relay × 24 | ||
| Analog | EH-D6EAN | 24V DC | Analog × 4 | Analog × 2 | |
| EH-A6EAN | 100/200V AC | Analog × 4 | Analog × 2 | ||
| RTD | EH-D6ERTD | 24V DC | RTD × 4 | Analog × 2 | |
| EH-D4ERTD | 24V DC | RTD × 4 | - | ||
| EH-A6ERTD | 100/200V AC | RTD × 4 | Analog × 2 | ||
| EH-A4ERTD | 100/200V AC | RTD × 4 | - | ||
| TC | EH-D6ETC | 24V DC | Thermocouple × 4 | Analog × 2 | |
| EH-D4ETC | 24V DC | Thermocouple × 4 | - | ||
| Expansion cable | EH-MCB10 | 1.0m | |||
| EH-MCB05 | 0.5m | ||||
| EH-MCB01 | 0.1m | ||||
| Option board | OBV-NES | RS-485 (2wire, RJ-45), 1ch. | |||
| OBV-485A | RS-485 (4wire, RJ-45), 1 port and 10-bit Analog input, 2ch. (terminal block) | ||||
| OBV-AIO | 10-bit Analog Input, 2ch. And 10-bit Analog Output, 2ch. (terminal block) | ||||
| OBV-485TAI | RS-485 (2wire, terminal block), 1 port and 10-bit Analog Input, 2ch. (terminal block) | ||||
| OBV-485TAO | RS-485 (2wire, terminal block), 1 port and 10-bit Analog Output, 2ch. (terminal block) | ||||
| Battery | MV-BAT | For data memory back-up. 3.0V / 1,750mAh | |||
[General specifications]
| Item | Specification | |
|---|---|---|
| Power supply type | AC | DC |
| Power voltage | 100/110/120V AC (50/60Hz), 200/220/240V AC (50/60Hz) | 24V DC |
| Power voltage fluctuation | 85 to 264V AC wide range | 19.2 to 30V DC |
| Operating ambient temp. | 0 to 55℃ | |
| Storage ambient humidity | 5 to 95% RH (no condensation) | |
| Vibration resistance | Conforming to IEC(EN) 62231-2 (147m/s², 3 times in each 3 directions X, Y, Z) | |
| Noise resistance |
| |
| Certifications | CE, RCM | |
| Insulation resistance | 20MΩ minimum between AC terminal and frame ground (FE) terminal (based on 500V DC megger) | |
| Dielectric withstand voltage | 1,500V AC for 1 minute between AC input terminal and frame ground (FE) terminal | |
| Ground | Class D grounding (grounding with the power supply module) | |
| Usage environment | No corrosive gases, no excessive dust | |
| Structure | Attached on an open wall | |
| Cooling | Natural air cooling | |
Dimensions [Unit : mm]
40 points type basic unit
64 points type basic/expansion unit
8/14/16/analog/RTD/TC expansion unit
28 points expansion unit
Advantage in your application
Detailed specification sheets are shown in the product images.
Catalogues
Programmable Logic Controllers MICRO-EHV+ Series
Programmable Logic Controllers MICRO-EHV+ Series: overview and buying guide
The Programmable Logic Controllers MICRO-EHV+ Series (model MICRO-EHV+ Series) is made by HITACHI INDUSTRIAL EQUIPMENT SYSTEMS and listed in our electronic range. Premium Emart sources it directly from the manufacturer and handles the quotation, inspection, export packing and international shipping, so you can buy it from anywhere in the world with a single point of contact.
Frequently asked questions
How much does the Programmable Logic Controllers MICRO-EHV+ Series cost?
Prices depend on the configuration, quantity and destination. Add the item to your RFQ list and we will send a free quotation with the unit price, lead time and shipping cost. There is no obligation to buy.
Can you ship the Programmable Logic Controllers MICRO-EHV+ Series to my country?
Yes. We export worldwide by sea, air or courier, with export packing and the commercial invoice, packing list and certificate of origin where required. The shipping options are shown in your quotation.
Is this a genuine HITACHI INDUSTRIAL EQUIPMENT SYSTEMS product?
We purchase directly from HITACHI INDUSTRIAL EQUIPMENT SYSTEMS or its authorised channels and confirm the model and specifications with the manufacturer before ordering.
What is the minimum order quantity?
For most items the minimum order is one unit. If the manufacturer sets a higher minimum, we tell you in the quotation.
Features
Powerful communication performance in one CPU
All models have Ethernet, serial, USB (host & device) communication ports as standard.
Additional communication ports can be realized by option boards.
Wide range of expansion units are available
MICRO-EHV+ Basic unit
No. of I/O is Max. 320 (using 64 pts expansion unit)
Specification
Basic units
I/O external connection : Removable type screw terminal block (M3)
[CPU specification]
| Item | 40 points type | 64 points type | |
|---|---|---|---|
| Platform | CODESYS Runtime V3.5 SP3 Patch4 | ||
| Boolean execution speed | 0.54µs/instruction | ||
| User Program memory | 1MB | ||
| Source file memory | 1MB | ||
| Data memory (non retain) | 640KB | ||
| Data memory (retain) | 256KB | ||
| Programming languages | IEC61131-3 compliant 5 languages (LD, FBD, SFC, IL, ST) | ||
| No. of expansion unit | 4 | ||
| No. of I/O (using 64pts exp. units) | 296 (In 184 / Out 112) | 320 (In 200 / Out 120) | |
| Special I/O | Single phase counter | Max. 5ch, 100kHz | |
| 2 phase counter | Max. 2ch, 60kHz | ||
| Pulse train output | Max. 3ch, 65kHz | ||
| PWM output | Max. 3ch, 65kHz | ||
| Interrupt | Max. 5ch | ||
| I/O updating cycle | Refresh processing (depends on each task cycle) | ||
| USB | Device function | For programming. Built-in USB 2.0 Full speed | |
| Host function | USB stick can be used for a copy of project and data logging | ||
| Ethernet | UDP/IP, TCP/IP | Programming, General purpose, Modbus-TCP server/client, EtherCAT® master | |
| Serial | RS-232C (Built-in) | General purpose, Modbus-RTU master and slave | |
| RS-485 (Option) | General purpose, Modbus-RTU master and slave | ||
| Web visualization function | Support | ||
| RTC | Built-in | ||
| Battery | Optional | ||
[Basic units]
| Class | Model Name | Specification | |||
|---|---|---|---|---|---|
| Power | Input | Output | Remarks | ||
| 40 points | MV-D40DTPS | 24V DC | DC24V × 24 | Transistor × 16 (short circuit protection) | Source |
| MV-D40DT | 24V DC | DC24V × 24 | Transistor × 16 | Sink | |
| MV-D40DR | 24V DC | DC24V × 24 | Relay × 16 | ||
| MV-A40DR | 100/200V AC | DC24V × 24 | Relay × 16 | ||
| 64 points | MV-D64DTPS | 24V DC | DC24V × 40 | Transistor × 24 (short circuit protection) | Source |
| MV-D64DT | 24V DC | DC24V × 40 | Transistor × 24 | Sink | |
| MV-D64DR | 24V DC | DC24V × 40 | Relay × 24 | ||
| MV-A64DR | 100/200V AC | DC24V × 40 | Relay × 24 | ||
[Expansion units]
| Class | Model Name | Specification | |||
|---|---|---|---|---|---|
| Power | Input | Output | Remarks | ||
| 8 points | EH-D8ED | 24V DC | 24VDC × 8 | - | |
| EH-D8ER | 24V DC | - | Relay × 8 | ||
| EH-D8ETPS | 24V DC | - | Transistor × 8 (short circuit protection) | Source | |
| EH-D8ET | 24V DC | - | Transistor × 8 | Sink | |
| ED-D8EDTPS | 24V DC | 24VDC × 4 | Transistor × 4 (short circuit protection) | Source | |
| EH-D8EDT | 24V DC | 24VDC × 4 | Transistor × 4 | Sink | |
| EH-D8EDR | 24V DC | 24VDC × 4 | Relay × 4 | ||
| 14 points | EH-D14EDTPS | 24V DC | 24VDC × 8 | Transistor × 6 (short circuit protection) | Source |
| EH-D14EDTP | 24V DC | 24VDC × 8 | Transistor × 6 | Source | |
| EH-D14EDT | 24V DC | 24VDC × 8 | Transistor × 6 | Sink | |
| EH-D14EDR | 24V DC | 24VDC × 8 | Relay × 6 | ||
| EH-A14EDR | 100/200V AC | 24VDC × 8 | Relay × 6 | ||
| 16 points | EH-D16ED | 24V DC | 24VDC × 16 | - | |
| EH-D16ER | 24V DC | - | Relay × 16 | ||
| EH-D16ETPS | 24V DC | - | Transistor × 16 (short circuit protection) | Source | |
| EH-D16ET | 24V DC | - | Transistor × 16 | Sink | |
| 28 points | EH-D28EDTPS | 24V DC | 24VDC × 16 | Transistor × 12 (short circuit protection) | Source |
| EH-D28EDTP | 24V DC | 24VDC × 16 | Transistor × 12 | Source | |
| EH-D28EDT | 24V DC | 24VDC × 16 | Transistor × 12 | Sink | |
| EH-D28EDR | 24V DC | 24VDC × 16 | Relay × 12 | ||
| EH-A28EDR | 100/200V AC | 24VDC × 16 | Relay × 12 | ||
| 64 points | EH-D64EDTPS | 24V DC | 24VDC × 40 | Transistor × 24 (short circuit protection) | Source |
| EH-D64EDT | 24V DC | 24VDC × 40 | Transistor × 24 | Sink | |
| EH-D64EDR | 24V DC | 24VDC × 40 | Relay × 24 | ||
| EH-A64EDR | 100/200V AC | 24VDC × 40 | Relay × 24 | ||
| Analog | EH-D6EAN | 24V DC | Analog × 4 | Analog × 2 | |
| EH-A6EAN | 100/200V AC | Analog × 4 | Analog × 2 | ||
| RTD | EH-D6ERTD | 24V DC | RTD × 4 | Analog × 2 | |
| EH-D4ERTD | 24V DC | RTD × 4 | - | ||
| EH-A6ERTD | 100/200V AC | RTD × 4 | Analog × 2 | ||
| EH-A4ERTD | 100/200V AC | RTD × 4 | - | ||
| TC | EH-D6ETC | 24V DC | Thermocouple × 4 | Analog × 2 | |
| EH-D4ETC | 24V DC | Thermocouple × 4 | - | ||
| Expansion cable | EH-MCB10 | 1.0m | |||
| EH-MCB05 | 0.5m | ||||
| EH-MCB01 | 0.1m | ||||
| Option board | OBV-NES | RS-485 (2wire, RJ-45), 1ch. | |||
| OBV-485A | RS-485 (4wire, RJ-45), 1 port and 10-bit Analog input, 2ch. (terminal block) | ||||
| OBV-AIO | 10-bit Analog Input, 2ch. And 10-bit Analog Output, 2ch. (terminal block) | ||||
| OBV-485TAI | RS-485 (2wire, terminal block), 1 port and 10-bit Analog Input, 2ch. (terminal block) | ||||
| OBV-485TAO | RS-485 (2wire, terminal block), 1 port and 10-bit Analog Output, 2ch. (terminal block) | ||||
| Battery | MV-BAT | For data memory back-up. 3.0V / 1,750mAh | |||
[General specifications]
| Item | Specification | |
|---|---|---|
| Power supply type | AC | DC |
| Power voltage | 100/110/120V AC (50/60Hz), 200/220/240V AC (50/60Hz) | 24V DC |
| Power voltage fluctuation | 85 to 264V AC wide range | 19.2 to 30V DC |
| Operating ambient temp. | 0 to 55℃ | |
| Storage ambient humidity | 5 to 95% RH (no condensation) | |
| Vibration resistance | Conforming to IEC(EN) 62231-2 (147m/s², 3 times in each 3 directions X, Y, Z) | |
| Noise resistance |
| |
| Certifications | CE, RCM | |
| Insulation resistance | 20MΩ minimum between AC terminal and frame ground (FE) terminal (based on 500V DC megger) | |
| Dielectric withstand voltage | 1,500V AC for 1 minute between AC input terminal and frame ground (FE) terminal | |
| Ground | Class D grounding (grounding with the power supply module) | |
| Usage environment | No corrosive gases, no excessive dust | |
| Structure | Attached on an open wall | |
| Cooling | Natural air cooling | |
Dimensions [Unit : mm]
40 points type basic unit
64 points type basic/expansion unit
8/14/16/analog/RTD/TC expansion unit
28 points expansion unit
Advantage in your application